Dental implant boyut ve tasarımının primer stabilite üzerindeki etkisinin farklı ölçüm cihazları ile in vitro karşılaştırılması

In vitro comparison of the effects of dental implant dimension and design on primary stability using different stability measurements devices

  1. Tez No: 1026419
  2. Yazar: TUNA SUMER
  3. Danışmanlar: PROF. DR. NİHAT AKBULUT
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: Ondokuz Mayıs Üniversitesi
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Bu in vitro çalışmanın amacı, farklı dental implant tasarımı, çapı, boyu ve kemik yoğunluğunun primer implant stabilitesi üzerindeki etkisini Osstell ISQ ve Penguin RFA cihazları ile değerlendirmektir. Materyal ve Metot: Çalışmada toplam 96 adet dental implant kullanılmıştır. İki farklı implant tasarımı (T6 Standart ve T6 Torq), iki farklı çap (3,5 ve 5,0/4,8 mm), iki farklı boy (8 ve 14 mm) kombinasyonu, PCF15 ve PCF30 yoğunluğa sahip sentetik kemik bloklara yerleştirilmiştir. İmplant stabilitesi Osstell ISQ ve Penguin RFA cihazları ile iki ayrı yönden ikişer kez ölçülmüştür. Elde edilen veriler istatistiksel olarak analiz edilmiştir. Bulgular: Her iki RFA cihazı yüksek düzeyde ölçüm uyumu ve tekrarlanabilirlik göstermiştir. Tüm ölçümler birlikte değerlendirildiğinde, her iki cihaz için de ICC değerinin 0,999'a ulaştığı görülmüştür. Kemik yoğunluğu primer stabilite üzerinde en güçlü etkiye sahip faktör olarak belirlenmiştir. Yüksek yoğunluklu kemik modelinde daha yüksek ISQ değerleri elde edilmiştir (p<0,001). İmplant boyu ve çapındaki artışın primer stabiliteyi anlamlı düzeyde artırdığı görülmüştür (p<0,001). İmplant tasarımının etkisi daha sınırlı olmakla birlikte, düşük yoğunluklu kemikte ve küçük boyutlu implant kombinasyonlarında T6 Torq implantlar daha yüksek ISQ değerleri göstermiştir (p<0,001). Sonuç: Primer implant stabilitesi üzerinde en belirleyici faktör kemik yoğunluğu olup, bunu implant boyu ve çapı takip etmektedir. Osstell ISQ ve Penguin RFA, primer implant stabilitesinin değerlendirilmesinde güvenilir ve tekrarlanabilir ölçüm cihazlarıdır. Düşük yoğunluklu kemikte, özellikle anatomik kısıtlamalar nedeniyle kısa boy ve dar çaplı implantların kullanılmasının gerekli olduğu durumlarda, daha agresif makrotasarıma sahip implantların seçilmesi primer stabilitenin artırılmasına katkıda bulunabilir.

Özet (Çeviri)

Aim: The aim of this in vitro study was to evaluate the effects of dental implant design, diameter, length, and bone density on primary implant stability using Osstell ISQ and Penguin Resonance Frequency Analysis (RFA) devices. Material and Methods: A total of 96 dental implants were included in the study. Combinations of two implant designs (T6 Standard and T6 Torq), two implant diameters (3,5 mm and 5,0/4,8 mm), and two implant lengths (8 mm and 14 mm) were placed into synthetic bone blocks with densities of PCF15 and PCF30. Implant stability was measured twice from two different directions using Osstell ISQ and Penguin RFA devices. The data were statistically analyzed. Results: Both RFA devices demonstrated high measurement agreement and reproducibility. When all measurements were evaluated collectively, the intraclass correlation coefficient (ICC) reached 0,999 for both devices. Bone density was identified as the most influential factor affecting primary implant stability. Significantly higher ISQ values were obtained in the high-density bone model (p<0,001). Increases in implant length and diameter significantly enhanced primary stability (p<0,001). Although the effect of implant design was relatively limited, T6 Torq implants exhibited significantly higher ISQ values than T6 Standard implants in low-density bone and small-dimension implant combinations (p<0,001). Conclusion: Bone density was the most important determinant of primary implant stability, followed by implant length and implant diameter. Osstell ISQ and Penguin RFA devices were found to be reliable and reproducible tools for the assessment of primary implant stability. In low-density bone, particularly in situations where the use of short and narrow implants is required because of anatomical limitations, selecting implants with a more aggressive macrodesign may contribute to improved primary stability.

Benzer Tezler

  1. Enfekte kök kanallarının N2, oxpara, poliantibiotik patlarıyla dezenfeksiyonu ve tedavisi

    Başlık çevirisi yok

    MUSTAFA KÖSEOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    1983

    Atatürk Üniversitesi

    Diş Hastalıkları ve Tedavisi Ana Bilim Dalı

    Yükleniyor...

  2. Üst tam protezlerde relining ve rebasing metodlarının tutuculuk yönünden karşılaştırılması

    Başlık çevirisi yok

    M.ÜSTÜN GÜLDAĞ

    Doktora

    Türkçe

    Türkçe

    1977

    Atatürk Üniversitesi

    Protez Ana Bilim Dalı

    Yükleniyor...

  3. Kompozit, isosit ve silikat dolguların su emme ve çözülme özelliklerinin araştırılması

    Başlık çevirisi yok

    A.SAMİ ANBARCIOĞLU

    Doktora

    Türkçe

    Türkçe

    1985

    Atatürk Üniversitesi

    Diş Hastalıkları ve Tedavisi Ana Bilim Dalı

    Yükleniyor...