Geri Dön

Isıyla polimerize edilen ve 3b yazıcılarla üretilen kaide materyallerinde sputter kaplama ile yapılan nanoboyutta silikon kaplanmasının, yüzey morfoloji değişikliklerinin ve farklı bağlayıcı ajanların silikon esaslı yumuşak astar materyali ile olan bağlantı değerlerine etkisinin değerlendirilmesi

Evaluation of the effect of sputter-coated nanoscale silicon coating, surface morphology changes, and different bonding agents on the bond strength of silicone-based soft liner material to heat-polymerized and 3D-printed denture base materials

  1. Tez No: 1028463
  2. Yazar: SERHAT AYDINLI
  3. Danışmanlar: PROF. DR. SAADET ATSÜ
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: 3 boyutlu yazıcı, tam protezler, dijital diş hekimliği, eklemeli üretim, 3B baskılı protezler, bilgisayar destekli tasarım, bilgisayar destekli üretim, yumuşak astar materyali, sterolitografi, sputter kaplama, termal siklus, çekme dayanımı, 3D printing, complete dentures, digital dentistry, additive manufacturing, 3D-printed dentures, computer-aided design, computer-aided manufacturing, soft lining material, stereolithography, sputter coating, thermocycling, tensile bond strength
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: Kırıkkale Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Protetik Diş Tedavisi Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Protez kaidesi ile yumuşak astar materyali arasındaki bağlantının kalitesi, yumuşak astar malzemesinin klinik ömrünü belirleyen en kritik parametrelerin başında gelmektedir; bu doğrultuda arayüzey bağlanma dayanımı yükseldikçe yumuşak astarın kullanım ömrü de uzamaktadır. Kaide ve astar arasındaki arayüzeyde meydana gelebilecek bağlantı başarısızlıkları, iki malzeme arasında plak ve diş taşı birikimine zemin hazırlayarak bakteri ve mantar kolonizasyonu için elverişli bir ortam yaratmaktadır. Bu durum, lokal ve sistemik enfeksiyon risklerini artırmasının yanı sıra, astar materyalinin protez kaidesinden tamamen ayrılmasına yol açarak malzemenin klinik işlevselliğini yitirmesine neden olmaktadır. Bu in vitro çalışmanın amacı; ısı ile polimerize PMMA (I) ve 3 boyutlu rezin (3B) kaide materyallerine uygulanan SiO2 sputter kaplamanın, yüzeyden yükselti oluşturacak şekilde tutucu eleman (buton) tasarımlarının ve farklı bağlayıcı ajanların (standart primer adeziv ve Visio.link), yapay yaşlandırma (termal siklus) sonrasında silikon esaslı yumuşak astar materyalinin çekme bağlanma dayanımı, yüzey pürüzlülüğü, ıslanabilirlik ve başarısızlık tipleri üzerindeki etkisini değerlendirmektir. Toplam 416 adet örnek, Isıyla polimerize PMMA için 6 farklı alt grup (n=20): kontrol (K), primer adeziv (A), Visio.link (V), SiO2 kaplama (Si), SiO2 kaplama + primer adeziv (SiA), SiO2 kaplama + Visio.link (SiV) oluşturulurken, 3B rezin için 7 farklı alt grup (n=20): kontrol (K), butonlu (B), butonlu + primer adeziv (BA), butonlu + Visio.link (BV), butonlu + SiO2 kaplama (BSi), butonlu + SiO2 kaplama + primer adeziv (BSiA), butonlu + SiO2 kaplama + Visio.link (BSiV) oluşturulmuştur. Hazırlanan disk şeklindeki numuneler (12.5 x 2 mm) yüzey incelenmesi amacıyla SEM analizi (n=2), yüzey pürüzlülüğü analizi (n=10) ve temas açısı (n=10) değerlendirilmesinde kullanılmıştır. Yüzey işlemi uygulanmış/uygulanmamış 2 dikdörtgen (15 x 10 x 10 mm) şeklindeki PMMA ve 3B rezin örnek arasına 3 mm kalınlığında yumuşak astar materyali (UfiGel P) uygulanarak çekme bağlanma dayanımı için örnekler hazırlanmıştır. Numunelerin yaşlandırılması amacıyla 10.000 döngülük 5-55 C° termal siklusa tabi tutulmuştur. Daha sonra instron test cihazında 1 mm/dak hızında çekme testine tabi tutulmuştur. Numuneler arasında meydana gelen başarısızlık tipleri x80 büyütme steromikroskop yardımıyla incelenmiştir. Verilerin istatistiksel analizleri Python (v3.11) yazılımı kullanılarak gerçekleştirilmiştir. Veriler Kruskal-Wallis ve Dunn-Bonferroni post-hoc testleri ile analiz edilmiş, anlamlılık düzeyi α=0.05 olarak kabul edilmiştir. Başarısızlık tiplerinin değerlendirilmesinde Likelihood Ratio testi uygulanmıştır. Çekme bağlantı dayanımı açısından en düşük değer I-K (0.25 ± 0.12 MPa), en yüksek değer ise 3B-BSiA grubunda (2.54 ± 0.47 MPa) elde edilmiştir (p<0.05). I-K ve I-SiV grupları hariç tüm deney grupları, klinik kabul edilebilir sınır olan 0,44/ MPa değerinin üzerinde kalmıştır. Yüzey pürüzlülüğü açısından; en yüksek değer I-V (1.46 ± 043 v μm), en düşük değer ise 3B-BV grubunda (0.45 ± 019 μm) elde edilmiştir (p < 0.05). Yüzey ıslanabilirliğinde; en yüksek temas açısı 3B-BSiA (108.91 ± 4.87°), en düşük temas açısı 3B-K grubunda (45.31 ± 11.06°) saptanmıştır (p<0.05). Başarısızlık tipleri incelendiğinde düşük bağlanma dayanımı gösteren gruplarda adeziv başarısızlıklar baskın iken, yüksek bağlantı dayanımı gösteren gruplarda karışık tip başarısızlıkların arttığı belirlenmiştir (p<0.05). Bu çalışmanın sınırları dahilinde, silikon esaslı yumuşak astar materyalinin protez kaide materyallerine bağlantısının artırılmasında yüzey modifikasyonlarının etkili olduğu görülmüştür. Özellikle 3B yazıcılarla üretilen kaide materyallerinde buton tasarımı ile adeziv kullanımının bağlantı dayanımını anlamlı düzeyde artırdığı belirlenmiştir. Isı ile polimerize edilen PMMA gruplarında en yüksek bağlanma dayanımı adeziv uygulanan grupta elde edilmiştir. SiO₂ kaplama, kontrol ve Visio.link grupları ile karşılaştırıldığında bağlanma dayanımını anlamlı düzeyde artırmış; ancak adeziv uygulanan gruplara kıyasla daha düşük bağlanma dayanımı değerleri göstermiştir. Yüzey pürüzlülüğü ve temas açısındaki değişimlerin bağlantı dayanımı ile her zaman doğru orantılı olmadığı, bağlantı başarısında kimyasal bağlanma mekanizmalarının ve makromekanik retansiyonun daha belirleyici olduğu sonucuna ulaşılmıştır.

Özet (Çeviri)

The quality of the bond between the denture base and soft liner material is one of the most critical parameters determining the clinical longevity of soft liner materials; accordingly, as the interfacial bond strength increases, the service life of the soft liner is prolonged. Bond failures occurring at the interface between the denture base and soft liner may facilitate plaque and calculus accumulation between the two materials, creating a favorable environment for bacterial and fungal colonization. This condition not only increases the risk of local and systemic infections but may also lead to complete separation of the liner material from the denture base, resulting in the loss of its clinical functionality. The aim of this in vitro study was to evaluate the effects of SiO₂ sputter coating, retentive button designs creating surface protrusions, and different bonding agents (standard primer adhesive and Visio.link) applied to heat-polymerized PMMA (I) and three-dimensional printed resin (3B) denture base materials on the tensile bond strength, surface roughness, wettability, and failure modes of a silicone-based soft liner material following artificial aging (thermocycling). A total of 416 specimens were prepared. For heat-polymerized PMMA, six subgroups (n=20) were established: control (K), primer adhesive (A), Visio.link (V), SiO₂ coating (Si), SiO₂ coating + primer adhesive (SiA), and SiO₂ coating + Visio.link (SiV). For 3D-printed resin, seven subgroups (n=20) were established: control (K), button-retained (B), button-retained + primer adhesive (BA), button-retained + Visio.link (BV), button-retained + SiO₂ coating (BSi), button-retained + SiO₂ coating + primer adhesive (BSiA), and button-retained + SiO₂ coating + Visio.link (BSiV). Disc-shaped specimens (12.5 × 2 mm) were prepared for surface characterization and used for SEM analysis (n=2), surface roughness evaluation (n=10), and contact angle measurements (n=10). For tensile bond strength testing, a 3-mm-thick layer of soft liner material (Ufi Gel P) was placed between two rectangular PMMA or 3D-printed resin specimens (15 × 10 × 10 mm) with or without surface treatment. To simulate aging, all specimens were subjected to 10,000 thermal cycles between 5°C and 55°C. Subsequently, tensile bond strength testing was performed using a universal testing machine at a crosshead speed of 1 mm/min. Failure modes occurring between the specimens were examined under a stereomicroscope at ×80 magnification. Statistical analyses were performed using Python software (v3.11). Data were analyzed using the Kruskal–Wallis test and Dunn–Bonferroni post-hoc test, with the significance level set at α=0.05. Failure mode distributions were evaluated using the Likelihood Ratio test. Regarding tensile bond strength, the lowest value was observed in the I-K group (0.25 ± 0.12 MPa), whereas the highest value was obtained in the 3B-BSiA group (2.54 ± 0.47 MPa) (p<0.05). All experimental groups, except I-K and I-SiV, exhibited bond strength values above the clinically acceptable threshold of 0.44 MPa. In terms of surface roughness, the highest value was recorded in the I-V group (1.46 ± 0.43 μm), while the lowest value was observed in the 3B-BV group (0.45 ± 0.19 μm) (p<0.05). Regarding wettability, the highest contact angle was measured in the 3B-BSiA group (108.91 ± 4.87°), whereas the lowest contact angle was observed in the 3B-K group vii (45.31 ± 11.06°) (p<0.05). Evaluation of failure modes revealed that adhesive failures predominated in groups exhibiting low bond strength, whereas mixed failures increased in groups demonstrating higher bond strength values (p<0.05). Within the limitations of this study, surface modifications were found to be effective in enhancing the bond strength of silicone-based soft liner materials to denture base materials. In particular, the combination of button design and adhesive application significantly increased bond strength in 3D-printed denture base materials. Among the heat-polymerized PMMA groups, the highest bond strength was obtained in the adhesive-treated group. SiO₂ coating significantly increased bond strength compared with the control and Visio.link groups; however, it demonstrated lower bond strength values than the adhesive-treated groups. It was concluded that changes in surface roughness and contact angle were not always directly proportional to bond strength, and that chemical bonding mechanisms and macromechanical retention played more decisive roles in bonding performance.

Benzer Tezler

  1. Purification of bacteriorhodopsin from halobacterium halobium and reconstitution studies in liposomes

    Başlık çevirisi yok

    M.BAKER ZABUT

    Yüksek Lisans

    İngilizce

    İngilizce

    1987

    Orta Doğu Teknik Üniversitesi

    Biyokimya Ana Bilim Dalı

    Yükleniyor...

  2. Albizzia julibrissin'in glikozitlerinin incelenmesi

    Başlık çevirisi yok

    NALAN KABAY

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Yükleniyor...

  3. Elektrik ark fırını yapımı

    Başlık çevirisi yok

    İSMAİL AKDOĞAN

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Gazi Üniversitesi

    Yükleniyor...

  4. Avrupa Topluluğu'nun bürokratik yapısı

    Başlık çevirisi yok

    GÜNİZ ODYAKMAZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1989

    İstanbul Üniversitesi

    Uluslararası İlişkiler Ana Bilim Dalı

    Yükleniyor...

  5. Kayseri yöresinde halıcılık ve yöre ekonomisine katkısı üzerine bir araştırma

    Başlık çevirisi yok

    KASIM KARAHAN

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Gazi Üniversitesi

    Yükleniyor...