Flash ve konvansiyonel radyoterapinin göz melanomunda doz dağılımı ve lineer enerji transfer (let) etkilerinin gate simülasyonuyla karşılaştırılması
Comparison of dose distribution and linear energy transfer (let) effects of flash and conventional radiotherapy in eye melanoma with gate simulation
- Tez No: 1030553
- Danışmanlar: DR. ÖĞR. ÜYESİ EYLEM GÜLCE ÇOKER
- Tez Türü: Yüksek Lisans
- Konular: Radyasyon Onkolojisi, Radiation Oncology
- Anahtar Kelimeler: Monte Carlo Yöntemi, Monte Carlo Method
- Yıl: 2026
- Dil: Türkçe
- Üniversite: İstanbul Aydın Üniversitesi
- Enstitü: Lisansüstü Eğitim Enstitüsü
- Ana Bilim Dalı: Yazılım Mühendisliği Ana Bilim Dalı
- Bilim Dalı: Sağlık Fiziği Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
Bu çalışmada, GATE Monte Carlo simülasyon kodu kullanılarak göz içi tümör tedavisine yönelik FLASH ve konvansiyonel radyoterapi koşullarında doz dağılımı ve LET (Linear Energy Transfer) hesaplanmıştır. Simülasyonda, yarıçapı 12 mm olan bir göz fantomu modellenmiş olup; sklera, koroid, retina, vitreus, lens, kornea, ön kamara ve optik sinir gibi anatomik alt yapılar detaylı geometrik tanımlamalarla oluşturulmuştur. Göz anatomisine ait bu boyutsal ve yapısal parametreler, ICRP referans anatomik model parametreleri temel alınarak belirlenmiştir. Ayrıca, koroid bölgesine temas edecek şekilde konumlandırılmış, elipsoidal yapıda, 17 mm taban çapına ve 11 mm kalınlığa sahip bir tümör hacmi Collaborative Ocular Melanoma Study (COMS) kriterleri esas alınarak modele dahil edilmiştir. Işın kaynağı, 6 MeV enerjili monoenerjik gama ışını üreten düzlemsel (plane) bir kaynak olarak tanımlanmış ve tümör hacmine yönlendirilmiştir. Parçacık etkileşimleri uygun fizik listesi ile modellenmiş ve doku içerisindeki enerji kayıpları ayrıntılı olarak izlenmiştir. Doz hesaplamaları, her bir göz yapısına atanmış DoseActor bileşenleri kullanılarak gerçekleştirilmiş ve 0.25 mm voksel boyutuna sahip yüksek çözünürlüklü üç boyutlu doz dağılımları elde edilmiştir. Bunun yanı sıra, parçacıkların birim yol başına bıraktığı enerji miktarını ifade eden Linear Energy Transfer (LET) değerleri de analiz edilmiş ve biyolojik etkinlik açısından yorumlanmıştır.
Özet (Çeviri)
In this study, dose distribution and Linear Energy Transfer (LET) were calculated for FLASH and conventional radiotherapy conditions targeting intraocular Tümör treatment using the GATE Monte Carlo simulation code. A spherical eye Fantom with a radius of 12 mm was modeled, and anatomical structures such as the sclera, choroid, retina, vitreous, lens, cornea, anterior chamber, and optic nerve were constructed using detailed geometrical definitions. The dimensional and structural parameters of the ocular anatomy were defined based on the ICRP reference anatomical model parameters. Additionally, an ellipsoidal Tümör volume, in contact with the Koroidal region and having a basal diameter of 17 mm and a thickness of 11 mm, was incorporated into the model according to the Collaborative Ocular Melanoma Study (COMS) criteria. The radiation source was defined as a planar source emitting monoenergetic 6 MeV gamma rays directed toward the Tümör volume. Particle interactions were modeled using appropriate physics lists, and energy losses within the tissue were tracked in detail. Dose calculations were performed using DoseActor components assigned to each ocular structure, and high-resolution three-dimensional dose distributions with a voksel size of 0.25 mm were obtained. Furthermore, Linear Energy Transfer (LET), representing the amount of energy deposited per unit path length by particles, was also analyzed and interpreted in terms of biological effectiveness.
Benzer Tezler
- Farklı ekim uygulamalarının serada Yalova-5 taze fasulye varyetesinin verim ve kalitesi üzerine etkileri
Başlık çevirisi yok
YASEMİN ÇELEBİ
- Hemiplejik hastaların rehabilitasyonunda brunnstrom ve NEH (Normal eklem hareketleri) tedavi yöntemlerinin karşılaştırılması
Başlık çevirisi yok
NURTEN DARDAĞAN
Yüksek Lisans
Türkçe
1986
Uludağ ÜniversitesiFiziksel Tıp ve Rehabilitasyon Ana Bilim Dalı
Yükleniyor...
- Pleurotus ostreatus mantarının bazı kağıtçılık hammaddelerinde yaptığı biyolojik degradasyon
Başlık çevirisi yok
M. KEMAL YALINKILIÇ
Yüksek Lisans
Türkçe
1987
Karadeniz Teknik ÜniversitesiOrman Endüstri Mühendisliği Ana Bilim Dalı
Yükleniyor...
- Güneş plajlarındaki gelişimin fotometrik incelenmesi ve flerlerin plajlara etkisi
Başlık çevirisi yok
ERDEN SOYTÜRK
- Polimerik membranlarda kimyasal ve makromoleküler yapının membranın oksijen ve iyonik geçirgenliğine etkileri
The Dependence of the anygen and ionic permeabilities of some polymeric membranes on their chemical and macromolecular structures
H. YILDIRIM ERBİL
- Polietilenglikol esaslı bazı yeni oligoazoperoksiester başlatıcıların sentezi ve karekterizasyonu
Synthesis and characterization of some new oligoazoperoxyester initiators based on polyethyleneglycolos
ALİPAŞA AYAS