Geri Dön

Self-resonant wireless power and data transfer link for retinal implants

Retinal implantlar için kendinden rezonanslı kablosuz güç ve veri aktarım bağlantısı

  1. Tez No: 1032252
  2. Yazar: ONUR BERK SUNAL
  3. Danışmanlar: DOÇ. DR. AHMET TEKİN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Biyomühendislik, Elektrik ve Elektronik Mühendisliği, Bioengineering, Electrical and Electronics Engineering
  6. Anahtar Kelimeler: Biyoprotez, Bioprosthesis
  7. Yıl: 2026
  8. Dil: İngilizce
  9. Üniversite: Boğaziçi Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Elektrik-Elektronik Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Elektrik Elektronik Mühendisliği Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Retina protezleri, retinitis pigmentosa ve yaşa bağlı makula dejenerasyonu gibi fotoreseptör hastalıkları nedeniyle görme yetisini kaybetmiş hastalarda kısmi görmeyi yeniden sağlar. Göz içine ya da üzerine yerleştirilen uyarıcı bir pil taşıyamaz; güç ve veri, gözlük çerçevesindeki vericiden gözdeki alıcıya kablosuz aktarılmalıdır. Bu bağlantının geometrisi sabit değildir: gözün dönmesi ve çerçevenin kayması, bobinler arasındaki kuplajı ve en iyi aktarım frekansını sürekli değiştirir. Sabit frekanslı bir sürücü yalnızca belirli bir geometride en uygun noktada çalışır. Bu tezde, harici saat gerektirmeyen, kendinden salınımlı rezonanslı bir sürücü geliştirilmiştir. Dönüştürücü, anahtarlama işaretini harici bir saat yerine rezonans devresinden türetir; böylece sürüş frekansı rezonansa kilitlenir ve kuplaj değiştikçe onu kendiliğinden izler. Verici seri bağlı iki, alıcı ise paralel bağlı iki bobin kullanır; sistem 1048 kHz'e ayarlanıp uyarıcıyı modelleyen sabit 400 Ω'luk yükte karakterize edilmiştir. Önerilen düşük yüklemeli iki sarımlı algılama bobininde kapalı döngü, alıcı gerilimini sabit frekanslı sürücü düzeyinde tutar; yalnızca en yakın konumda küçük bir kayıp oluşur. Dereceli bir açı düzeneğiyle karakterize edilen dik eksenli çift bobinli alıcı, her açıda tek eksenli bağlantının önünde kalır ve dikey düzlemde gerilimini sabit tutar. Sinyal almanın devreyi yüklemesi üç durumlu bir ölçümle ayrıldığından, dayanıklılık öne sürülmek yerine karakterize edilmiştir. İleri yönlü veri aktarımı, taşıyıcının genlik kaydırmalı anahtarlanması ve bit saatinin taşıyıcıdan türetilmesiyle gösterilmiştir. Bu çalışmanın temel katkısı, harici saat gerektirmeyen otomatik rezonans izlemedir.

Özet (Çeviri)

Retinal prostheses restore a degree of vision to patients blinded by photoreceptor-degenerative disease such as retinitis pigmentosa and age-related macular degeneration. The stimulator in or on the eye cannot carry a battery, so it must receive both power and data wirelessly, over a link from a spectacle frame to the eye whose geometry is not fixed: the eye rotates and the frame shifts, so the coil coupling and the frequency of best transfer change continuously during use. A driver fixed to a single frequency is optimal at only one geometry. This thesis develops a clock-free, self-oscillating resonant driver for such a link. Rather than being driven from an external clock, the converter derives its switching from the tank itself, so the drive frequency locks to the resonance and tracks it automatically as the coupling changes. The transmitter uses two series-connected coils and the receiver two parallel coils, tuned to 1048 kHz and delivering power into a fixed 400 Ω load that models the stimulator. At the proposed low-loading two-turn pickup, the self-oscillating loop sustains the delivered voltage as the link is moved, remaining comparable to the fixed-frequency drive except for a small pickup-loss penalty at the closest spacing. The orthogonal two-coil receiver, characterized with a graduated angle jig, stays ahead of a single-axis link at every gaze angle and in the vertical plane holds its delivered voltage flat rather than sagging as the eye turns. Because sensing the tank for feedback inevitably loads it, a three-condition protocol separates the loop's contribution from this loading, so the movement-robustness is characterized rather than merely asserted. A forward data link is demonstrated by amplitude-shift keying the carrier through supply chopping, with a bit clock counted from the carrier itself. Clock-free, automatic resonance tracking is the central contribution of this work.

Benzer Tezler

  1. Design of a compact bidirectional rf front-end module for 24–30 GHz 5g applications

    24-30 GHz 5g uygulamaları için kompakt çift yönlü rf ön uç modülü tasarımı

    HÜSEYİN CAHİT ERBİL

    Yüksek Lisans

    İngilizce

    İngilizce

    2026

    İstanbul Teknik Üniversitesi

    Elektronik ve Haberleşme Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  2. Multicolor fluorescence microscopy fortracking magnetic micro-agents

    Başlık çevirisi yok

    MERT KAYA

    Doktora

    İngilizce

    İngilizce

    1989

    Unıversıty Of Twente

    Yükleniyor...

  3. Küçük ölçekli bir piezoelektrik rüzgar enerjisi hasat sisteminin açık kaynaklı akışkan yapı etkileşim modelinin oluşturulması

    Development of an open-source fluid-structure interaction model of a small-scale piezoelectric wind energy harvesting system

    TURAN MIRZALI

    Yüksek Lisans

    Türkçe

    Türkçe

    2025

    Bursa Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  4. Nanoboyutlu yarıiletkenlerin yoğunluk fonksiyoneli kuramı ile tasarımı ve bilgisayar benzetimi

    Computer simulation and design of nanoscale semiconductors by using density functional theory

    HİKMET HAKAN GÜREL

    Doktora

    Türkçe

    Türkçe

    2011

    İstanbul Teknik Üniversitesi

    Hesaplamalı Bilim ve Mühendislik Ana Bilim Dalı (disiplinlerarası)

    Yükleniyor...

  5. Baba yoksunluğunun benlik kavramına etkisi ve babasız öğrencilerin problemlerinin hangi alanlarda yoğunlaştığının saptanması

    Başlık çevirisi yok

    OYA GÜNGÖRMÜŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    İstanbul Üniversitesi

    Gelişim Psikolojisi Ana Bilim Dalı

    Yükleniyor...