Sürtünmeli sarkaç tipi sismik izolatörlü betonarme çerçeve yapıların deprem davranışlarının karşılaştırılması
A comparison of the seismic behaviour of reinforced concrete frame structures with friction pendulum-type seismic isolators
- Tez No: 1032882
- Danışmanlar: DOÇ. DR. MEHMET EMİN ÖNCÜ
- Tez Türü: Yüksek Lisans
- Konular: İnşaat Mühendisliği, Civil Engineering
- Anahtar Kelimeler: Deprem performansı, Doğrusal olmayan analiz, Sismik taban yalıtımı, Earthquake performance, Nonlinear analysis, Seismic base isolation
- Yıl: 2026
- Dil: Türkçe
- Üniversite: Dicle Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: İnşaat Mühendisliği Ana Bilim Dalı
- Bilim Dalı: Yapı Mühendisliği Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
Aktif fay hatlarının yoğun olduğu bölgelerde sismik izolasyon teknolojisi önem taşımaktadır. Bu yöntem yapıları zemin hareketinden ayırarak sismik enerjiyi kaynağında sönümler. Yapısal hasarı önleyen en etkili pasif kontrol mekanizmalarından biri haline gelmiştir bu teknoloji. Ancak literatürde sismik izolatörlerin performansı çoğunlukla alçak binalar üzerinde incelenmiştir. Orta veya yüksek katlı binalar için de çalışmalar yer almaktadır. Çok katlı yapılarda kat adedinin sismik davranış üzerindeki etkileri ise yeterince detaylandırılmamıştır. Maliyet üzerindeki etkiler de bu yüzden netleşmemiştir. Bu tez çalışmasında kat yüksekliğinin taban yalıtımlı binaların deprem performansı üzerindeki yapısal etkilerinin ortaya konulması amaçlanmıştır. Kütle artışının sınırları da kapsamlı bir şekilde inceleniyor bu süreçte. Çalışma kapsamında plan geometrisi tamamen simetrik ve düzenli olan üç farklı betonarme çerçeve bina modeli ele alındı. Yükleme koşulları da homojen olan bu modeller her biri 5x5 açıklıklı 10, 12 ve 14 katlı binalardan oluşmaktadır. Yapıların temeli ile kolonları arasındaki yalıtım düzleminde sismik izolatör kullanılmaktadır. Bu düzlemde Sürtünmeli Sarkaç Tipi (FPS) sismik izolatörler tercih edilmiştir. Modellerin sismik analizlerinde Türkiye Bina Deprem Yönetmeliği (TBDY-2018) temel alınmıştır. ASCE 7-22 standartları da bu tasarım hesaplarında kullanılıyor. En büyük deprem yer hareketi düzeyi (MCE/DD-1) altındaki doğrusal ve doğrusal olmayan analizler yapılmıştır. Doğrusal olmayan zaman tanım alanında hesap yöntemleri de bu sürece dahil edilmiştir. Bu çalışmada sürtünmeli sarkaç tipi (FPS) sismik izolatör kullanılan 10, 12 ve 14 katlı betonarme yapıların deprem performansları doğrusal olmayan zaman tanım alanında incelenmiştir. Yapılar ETABS programında modellenmiş ve 11 adet farklı deprem kaydı altında analiz edilmiştir. Analiz sonuçları doğal titreşim periyotları, kat deplasmanları, kat ötelenme oranları, izolatör deformasyonları ve deprem yükleri açısından karşılaştırılmıştır. Elde edilen bulgular, kat sayısının artmasıyla birlikte yapı periyotlarının ve tepe kat deplasmanlarının arttığını göstermiştir. Buna karşın izolatör deformasyonlarının tüm modellerde benzer seviyelerde kaldığı ve deprem enerjisinin büyük bölümünün izolasyon düzeyinde karşılandığı belirlenmiştir. Kat ötelenme oranlarının üstyapıda oldukça düşük seviyelerde kalması, FPS sisteminin deprem etkilerini etkin şekilde azalttığını ortaya koymuştur. Sonuç olarak FPS sismik izolasyon sisteminin 10, 12 ve 14 katlı betonarme yapılarda etkin performans gösterdiği belirlenmiştir. Yapı yüksekliği arttıkça deplasman taleplerinde artış meydana gelmesine rağmen, izolatörlerin deprem enerjisini başarılı şekilde sönümlediği ve üstyapı katlarında oluşan göreli ötelenmeleri önemli ölçüde azalttığı görülmüştür. Elde edilen sonuçlar FPS sistemlerinin farklı yapı yüksekliklerinde güvenli ve etkili bir deprem koruma yöntemi olduğunu ortaya koymaktadır.
Özet (Çeviri)
Seismic isolation technology has become increasingly important in regions where active fault lines are concentrated. This technology decouples structures from ground motion and dissipates seismic energy at its source. As a result, it has become one of the most effective passive control mechanisms for preventing structural damage. However, in the literature, the performance of seismic isolators has been predominantly investigated in low-rise buildings. Although studies on medium- and high-rise buildings are also available, the effects of the number of stories on the seismic behavior of multi-story structures have not been sufficiently detailed. Consequently, the impact of building height on the overall effectiveness and cost efficiency of seismic isolation systems remains unclear. The aim of this thesis is to investigate the structural effects of building height on the seismic performance of base-isolated buildings. In addition, the limitations associated with increasing structural mass are comprehensively examined. Within the scope of the study, three reinforced concrete frame building models with completely symmetric and regular plan geometries were considered. Subjected to identical loading conditions, these models consist of 10-, 12-, and 14-story buildings with a 5×5 bay configuration. Seismic isolators were installed at the isolation interface located between the foundation and the columns. Friction Pendulum System (FPS) seismic isolators were selected for this isolation level. The seismic analyses of the models were conducted based on the provisions of the Turkish Building Earthquake Code (TBEC-2018), while the design calculations were also evaluated according to the requirements of ASCE 7-22. Both linear and nonlinear analyses were performed under the Maximum Considered Earthquake (MCE/DD-1) ground motion level. Furthermore, nonlinear time-history analysis procedures were included in the study. In this research, the seismic performance of 10-, 12-, and 14-story reinforced concrete buildings equipped with Friction Pendulum System (FPS) seismic isolators was investigated through nonlinear time-history analyses. The structures were modeled using ETABS software and analyzed under eleven different earthquake ground motion records. The analysis results were compared in terms of natural vibration periods, story displacements, interstory drift ratios, isolator deformations, and seismic force demands. The findings indicate that increasing the number of stories results in longer structural periods and greater roof displacements. However, isolator deformations remained at similar levels in all models, indicating that a significant portion of the seismic energy was dissipated at the isolation level. Moreover, the low interstory drift ratios observed throughout the superstructure demonstrated the effectiveness of the FPS system in reducing seismic effects. As a result, the FPS seismic isolation system was found to provide effective performance in 10-, 12-, and 14-story reinforced concrete buildings. Although displacement demands increased with building height, the isolators successfully dissipated seismic energy and significantly reduced relative story drifts within the superstructure. The results demonstrate that FPS systems constitute a safe and effective seismic protection method for buildings of different heights.
Benzer Tezler
- Tekstil boyamacılığında atık flottede boyama imkanları üzerine araştırma
Başlık çevirisi yok
MEHMET YAKARTEPE
- Dört zamanlı türbaşarj direk püskürtmeli bir dizel motorunun bilgisayar ile sümülasyonu
Computer aided simulation of a fourstroke turbocharged direct-anjection diesel engine
MUSTAFA BALCI
- Ötektoidaltı çeliklerin kayma sürtünmesi aşınmasında adhesiv aşınma katsayısının araştırılması
Başlık çevirisi yok
DURMUŞ ODABAŞ
- Hidrolik kontrol valflerinde çalışma kuvvetleri
Operating forces in hydraulic control valves
MUSTAFA İNAL