Geri Dön

Yüksek gerilim hatlarına ve diğer faktörlere bağlı düşük frekanslı elektromanyetik kirlilik durumunun belirlenmesi ve bazı sağlık etkilerinin belirlenmesi

Determination of electromagnetic pollution to high voltage powerlines and other sources and some of its possible health effects

  1. Tez No: 107875
  2. Yazar: SONGÜL ACAR VAİZOĞLU
  3. Danışmanlar: PROF.DR. ÇAĞATAY GÜLER
  4. Tez Türü: Doktora
  5. Konular: Halk Sağlığı, Public Health
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2001
  8. Dil: Türkçe
  9. Üniversite: Hacettepe Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Halk Sağlığı Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 179

Özet

Yüksek gerilim hatlarına ve diğer faktörlere bağlı düşük frekanslı elektromanyetik kirlilik durumunun ve bazı sağlık etkilerinin belirlenmesi, Hacettepe Üniversitesi Sağlık Bilimleri Enstitüsü Halk Sağlığı Programı Doktora Tezi, Ankara, 2001. Bu araştırma, Ankara Büyükşehir Belediyesi sınırlan içinde Yüksek Gerilim Hatlarının altında ve bu hatlara yakın ve uzak olan evlerde, elektromanyetik alan düzeyini ve bazı olası sağlık etkilerini saptamak amacı ile yapılmıştır. Ölçümlerde triaxial gausmetre kullanılmıştır. Araştırma, Yüksek Gerilim Hatlarının 0-100 m çevresinde bulunan 73 ev ve en az 1000 m uzaklıkta olan 70 evde tamamlanmıştır. Bu evlerde yaşayan 278 kişiye bazı sağlık sorunları ile ilgili bir anket uygulanmıştır. Yüksek Gerilim Hatlarının altmda ve sağından solundan 10 m uzaklıklardan olmak üzere toplam 1076 ölçüm yapılmıştır. Yüksek Gerilim Hatlarının altmda bulunan elektromanyetik alan ortalaması 12+ 0,6 mG, ortanca değer 9,1 mG, en yüksek değer ise 86,1 mG'tur. Yüksek Gerilim Hatlarına yakın olan evlerde yapılan elektromanyetik alan ölçümlerinin ortalaması 9,1±1,0 mG, ortanca 6,1 mG ve en yüksek ev ortalaması 34,4 mG'tur. Bu hatlarından uzak olan evlerde ise bu değerler sırası ile 1,5±0.1 mG, 1,3 mG ve 4,3 mG'tur. Yüksek Gerilim Hatlarına yakın ve uzak olan evlerin bütün bölümlerinde Mann- Whitney U testi kullanılarak yapılan ortalamalar arasındaki farkın anlamlılık testi sonucunda, iki grupta bulunan elektromanyetik alan düzeyleri arasında istatistiksel olarak anlamlı bir fark bulunmuştur (p

Özet (Çeviri)

Determination of electromagnetic pollution due to high voltage powerlines and other sources and some of its possible health effects, Hacettepe University Health Sciences Institute PhD Thesis in Public Health, Ankara, 2001 In this descriptive study electromagnetic fields from high voltage power lines within the boundries of Ankara Metropolitan Municipality and electromagnetic field levels of residences which are close (0-100 m) and far (at least 1000m) from these powerlines are measured by using a triaxial gaussmeter. The study is completed in 143 houses, of which 73 are close and 70 are far from the power lines. Also a questionnaire is given to the residents of these houses older than 15 years of age. 278 participants have filled the questionnaire. Electromagnetic fields of 367 power lines is measured. The mean is 12 mG, median is 9,1 mG and the maximun level is 86,1 mG. The mean value of electromagnetic field levels in the houses, which are close to the high voltage power lines and far from the power lines are 9,1 mG, 1,5 mG, respectively. A statistically significant difference between the means of the houses close to the power lines and far from the power line is found (p2 mG. A negative relation is found between the distance from power lines and the electromagnetic level found in the houses (p

Benzer Tezler

  1. Corona characteristics and electromagnetic effects of high DC voltages

    Yüksek doğru gerilim korona karakteristikleri ve elektromanyetik etkileri

    SHAYAN SHAHI GHARAAGHAJI

    Yüksek Lisans

    İngilizce

    İngilizce

    2020

    Elektrik ve Elektronik Mühendisliğiİstanbul Teknik Üniversitesi

    Elektrik Mühendisliği Ana Bilim Dalı

    Prof. Dr. AYDOĞAN ÖZDEMİR

  2. Yüksek gerilimde kullanılan gazların, deşarj olaylarının deneysel olarak incelenmesi

    High voltage used gases, discharge experimental investigation events

    TANER DİNDAR

    Yüksek Lisans

    Türkçe

    Türkçe

    2012

    Elektrik ve Elektronik MühendisliğiMarmara Üniversitesi

    Elektrik Eğitimi Ana Bilim Dalı

    DOÇ. DR. N.FUSUN OYMAN SERTELLER

    YRD. DOÇ. DR. TAHİR ÇETİN AKINCI

  3. Dependent failures and failure propagation in electric power systems

    Elektrik sistemlerinde bağımlı hata ve arıza yayılması

    KEYSAN SAEILAILONAHAR

    Yüksek Lisans

    İngilizce

    İngilizce

    2013

    Elektrik ve Elektronik Mühendisliğiİstanbul Teknik Üniversitesi

    Elektrik Mühendisliği Ana Bilim Dalı

    PROF. DR. AYDOĞAN ÖZDEMİR

  4. Investigation of mechanoregulatory role of desmin protein

    Investigation of mechanoregulatory role of desmin protein

    NİLÜFER DÜZ

    Doktora

    Türkçe

    Türkçe

    2024

    Tıbbi BiyolojiHacettepe Üniversitesi

    Tıbbi Biyoloji Ana Bilim Dalı

    PROF. DR. PERVİN RUKİYE DİNÇER

  5. Factors affecting the NATO mission in Afghanistan

    Afganistan'daki NATO misyonunu etkileyen faktörler

    SEBGHATULLAH SINA

    Yüksek Lisans

    İngilizce

    İngilizce

    2024

    Uluslararası İlişkilerİstanbul Medeniyet Üniversitesi

    Uluslararası İlişkiler Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ ELNUR İSMAYIL