İnhomojen dokularda analitik anizotropik ve pencil beam convolution algoritmalarıyla hesaplanan dozların karşılaştırılması
Comparison of doses calculated by anisotropic analytical algorithm and pencil beam convolution in the inhomogeneous tissues
- Tez No: 316751
- Danışmanlar: PROF. DR. MELAHAT GARİPAĞAOĞLU
- Tez Türü: Yüksek Lisans
- Konular: Onkoloji, Radyoloji ve Nükleer Tıp, Oncology, Radiology and Nuclear Medicine
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2012
- Dil: Türkçe
- Üniversite: Acıbadem Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Radyasyon Onkolojisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 121
Özet
İnsan vücudu kemik, akciğer ve yumuşak doku gibi farklı yoğunluklara sahip dokular içermektedir. Işının geçtiği dokularda su eşdeğeri olmayan inhomojen ortamların varlığı, doz dağılımlarında değişikliklere sebep olacaktır. Işınlanan dokularda dozun doğru olarak belirlenebilmesi için, doz hesaplama algoritmaları inhomojen yapılarda doğru modelleme yapmalıdır. Bu çalışmada yoğunluk ayarlı radyoterapi planlarında (YART) Anizotropik Analitik (AAA) ve Pencil Beam Convolution (PBC) algoritmalarının inhomojen dokulardaki doz dağılımları karşılaştırılmıştır. Ayrıca iyon odası ölçümleriyle hesaplanan ve ölçülen dozların uyumu incelenmiş, homojen ve inhomojen fantomlarda algoritmaların profil ve yüzde derin doz (YDD) eğrileri karşılaştırılmıştır. Bunun yanında AAA ve PBC kullanılarak hesaplanan YART planlarında hedef hacim içerisinde var olan hava eşdeğeri doku hacminin elde edilen doz dağılımına etkisi araştırılmıştır. AAA ve PBC'nin doz dağılımları karşılaştırıldığında, risk altındaki organların maruz kaldığı dozlar arasında klinikte ihmal edilebilecek fark saptanırken, hedef hacim içerisindeki sıcak doz bölgesinin hacmi AAA ile PBC'den anlamı olarak fazla bulunmuştur (p=0.005). Homojen fantomda hesaplanan ve ölçülen dozlar karşılaştırıldığında AAA planları için alamlı fark bulunamazken (p=0.074) PBC planları için anlamlı fark bulunmuştur (p=0.012) fakat bu fark %3'ten küçüktü. İnhomojen fantomda ise hesaplanan ve ölçülen dozlar karşılaştırıldığında AAA planları için anlamlı fark yokken (p=0.139) PBC planları için anlamlı fark saptanmıştır (p=0.007) ve bu fark %6'dan büyüktü. AAA ve PBC'nin homojen fantomdaki YDD ve profilleri arasında anlamlı fark olmamakla beraber inhomojen fantomdaki profil eğrilerinde, özellikle alan kenarlarında anlamlı fark bulunmuştur. İnhomojen fantomdaki YDD'ler incelendiğinde ise hava eşdeğeri dokuyu AAA ve PBC birbirlerinden farklı modellemişlerdir. Ayrıca, hedef içerisindeki hava eşdeğeri hacmin miktarı arttıkça, planlarda maksimum doz ve sıcak doz hacminin arttığı gözlenmiştir.
Özet (Çeviri)
The human body consists of tissues, which have different densities. These inhomogeneous densities effect the dose distributions. In order to get accurate dose distribution in the intensity modulated radiotherapy (IMRT), treatment planning system dose calculation algorithms should model precisely. Dose distributions of Anisotropic Analytical Algorithm (AAA) and Pencil Beam Convolution (PBC) dose calculation algorithms in the inhomogeneous tissues were compared. Furthermore calculated doses were verified as dose measurements using ionization chamber. Moreover, dose profiles and percentage depth dose (PDD) curves created by AAA and PBC were investigated. Whether the amount of tissue volume with air density included by planning target volume has an effect on dose distribution was studied. Calculated organs at risk doses by AAA and PBC were significantly different but clinically negligible. On the other hand, hot spot region was larger in AAA than PBC plans (p=0.005). For homogeneous phantom, calculated and measured doses were not significantly different in AAA plans (p=0.074), in contrast significantly different in PBC plans (p=0.012), all the differences were limited within %3. For inhomogeneous phantom, calculated and measured doses were not significantly different for AAA (p=0.139), significantly different for PBC (p=0.007); this difference was >6%. While there was no significant difference between AAA and PBC created PDDs and dose profiles in the homogeneous phantom, significant difference was seen in the inhomogeneous phantom. Disparity was markedly seen in sharp in the regions outside the ? eld edge. Maximum dose and hot spot region increased with the amount of tissue volume with air density included by planning target volume for both algorithms.
Benzer Tezler
- Akciğer tümörlerinde yoğunluk ayarlı ark radyoterapi tekniği kullanılarak iki farklı optimizasyon algoritmasının doz dağılımına etkisinin incelenmesi
Investigation of two different doses distribution optimization algorithm in lung tumors using with intensity modulated arc radiotherapy technique
GÖRKEM ÇEVİKBAŞ
Yüksek Lisans
Türkçe
2016
Onkolojiİstanbul ÜniversitesiTemel Onkoloji Ana Bilim Dalı
PROF. DR. HATİCE BİLGE BECERİR
- 60 co kaynaklı yüksek enerji foton demetlerine duyarlı filmlerden densitometrik teknik ile tümör dozunun belirlenmesi
Using films, sensitive to high energy photons, for tumour dose determination by densytmetric technique 60 co
ADEM ÜNAL KIZILDAĞ
Yüksek Lisans
Türkçe
2004
Fizik ve Fizik MühendisliğiAkdeniz ÜniversitesiFizik Ana Bilim Dalı
DR. NİNA TUNÇEL
Y.DOÇ.DR. ŞERAFETTİN YALTKAYA
- Radyoterapi tedavi planlaması için hounsfield unit ve rölatif elektron yoğunluğu arasındaki ilişki
The relationship between hounsfield unit and relative electron density for radiotherapy treatment planning
ÇİĞDEM AYDOĞDU
Yüksek Lisans
Türkçe
2022
Fizik ve Fizik MühendisliğiÇanakkale Onsekiz Mart ÜniversitesiFizik Ana Bilim Dalı
PROF. DR. EMİNE DİLARA ATALAY
DR. ÖĞR. ÜYESİ İSMAİL FARUK DURMUŞ
- Akciğer stereotaktik body radyoterapi uygulamalarının fiziksel ve dozimetrik incelenmesi
Physical and dosimetric analysis of lung stereotactic body radiation therapy
İSMAİL FARUK DURMUŞ
Doktora
Türkçe
2018
Fizik ve Fizik MühendisliğiÇanakkale Onsekiz Mart ÜniversitesiFizik Ana Bilim Dalı
DOÇ. DR. EMİNE DİLARA ATALAY
- 3-d gamma knife dose distribution by normoxic gel dosimetry near tissue inhomogeneties
Doku inhomojenite yakınlarında üç boyutlu gamma knife doz dağılımının normoksik jel dozimetre ile incelenmesi
FATİH İŞBAKAN
Doktora
İngilizce
2005
BiyomühendislikBoğaziçi ÜniversitesiBiyomedikal Mühendisliği Ana Bilim Dalı
PROF. DR. YEKTA ÜLGEN