The design and evaluation of a small size wind-solar hybrid power system
Başlık çevirisi mevcut değil.
- Tez No: 401187
- Danışmanlar: DR. MOHAMMED FAHMY, DR. SCOTT GREENHALGH
- Tez Türü: Doktora
- Konular: Elektrik ve Elektronik Mühendisliği, Electrical and Electronics Engineering
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2013
- Dil: İngilizce
- Üniversite: University of Northern Iowa
- Enstitü: Yurtdışı Enstitü
- Ana Bilim Dalı: Belirtilmemiş.
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 119
Özet
Özet yok.
Özet (Çeviri)
Renewable energy sources are considered as alternative energy sources in order to replace current energy production systems and meet energy demands in the future. Renewable hybrid energy systems consist of two or more energy sources. Wind and solar energy sources are environmentally friendly, domestic, and finite energy sources. Either wind or solar applications may not be individually feasible to meet energy demand at some areas. However, combining these two energy sources will allow the use of energy systems effectively. There are two main concerns while designing and analyzing wind-solar hybrid power systems: system power reliability under varying climate conditions and corresponding system cost. Developments of new technology application of hybrid power systems reduce cost and raise power capacities which make such systems very popular for some countries. This research investigates the design and economic aspects, and analyses of a small size grid connected wind-solar hybrid power system at the University of Northern Iowa. This research provides a simulation study for the power system under fault operations. ETAP and HOMER simulation software tools are used in order to perform simulation studies for this research. The outcome from several case studies will be presented using simulated grid connected wind-solar hybrid power system. Simulation case studies are: Case study I: Load flow analysis. Case Study II: DC load flow analysis due to adding the battery array to the system. Case Study III: Unbalanced load flow analysis due to a phase fault of three phases of the power system. Each case study concentrates on the system's behavior and reaction under different working condition
Benzer Tezler
- Kolza sap-samanı ısıl davranımının termogravimetrik yöntemle incelenmesi
Başlık çevirisi yok
BÜLENT D. ÇİFT
Yüksek Lisans
Türkçe
1998
Kimya Mühendisliğiİstanbul Teknik ÜniversitesiKimya Mühendisliği Ana Bilim Dalı
DOÇ. DR. FİLİZ KARAOSMANOĞLU
- Nokta soğurucu tipi dalga enerjisi dönüştürücüsü dizilerinin hidrodinamik analizi
Hydrodynamic analysis of point absorber type wave energy converter arrays
İLKAY ÖZER ERSELCAN
Doktora
Türkçe
2017
Mühendislik Bilimleriİstanbul Teknik ÜniversitesiGemi ve Deniz Teknoloji Mühendisliği Ana Bilim Dalı
PROF. DR. ABDİ KÜKNER
- Giydirme cephe çift cam ünitelerinde rasyonel boyut seçimi
Selection of rational sizes for double glazing units in curtaion walls
NECMETTİN MURAT AYGÜN
- Türkiye'deki rüzgar gücü potansiyeline göre türbin güçlerinin saptanması ve tasarımı
Determining the turbine power and desing according to wind energy potential in Turkey
BARIŞ SAMSUN
Yüksek Lisans
Türkçe
2004
Makine Mühendisliğiİstanbul Teknik ÜniversitesiMakine Mühendisliği Ana Bilim Dalı
PROF. DR. METE ŞEN