Odaklı ultrason terapisinde frekans eniyilemesi için dokuda ısı yayılım modeli geliştirilmesi ve manyetik rezonans yardımı ile doğrulanması

A model for frequency optimization in high intensity focused ultrasound therapy and its verification using magnetic resonance thermometry

  1. Tez No: 476677
  2. Yazar: BERK SİLEMEK
  3. Danışmanlar: DOÇ. DR. ARİF SANLI ERGÜN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Elektrik ve Elektronik Mühendisliği, Electrical and Electronics Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2017
  8. Dil: Türkçe
  9. Üniversite: TOBB Ekonomi ve Teknoloji Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Elektrik-Elektronik Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 58

Özet

Yüksek yoğunluklu odaklı ultrason (HIFU), günümüzde pek çok hastalığın tedavisi için umut vadeden bir teknolojidir. Doku eritmesi ve ilaç teslimatı gibi iki temel tedavi yöntemi üzerine çalışılan bu teknolojide, süre ve dozaj önemli bir rol oynamaktadır. Doku eritmesinde kısa sürede çok yüksek derecelere ulaşılmasına karşın ilaç teslimatı gibi uygulamalarda daha uzun süreli düşük derecelerde terapi uygulanır. Her iki terapide de önemli olan nokta ise hedef dışındaki dokulara zarar vermemektir (örn. Deri). Bu sebeple geliştirilen pek çok yöntemlerden birisi de frekans eniyilemesidir. Frekans eniyilemesi, hedef dokunun derinliğine bağlı olarak verilen frekansı ayarlayarak sadece istenilen noktayı yakmak için verilen akustik gücü ayarlamaya yarar. Literatürdeki çalışmalarda frekans eniyilemesinin analitik çözümü mevcuttur fakat deneysel olarak gösterilen çalışmalar henüz bu frekans eniyilemesi teorisini tam olarak doğrulamamıştır. Bu tezde, bir HIFU sisteminin doku ile birlikte modellenmesi ve bu modelin Manyetik Rezonans (MR) kullanarak doğrulanması amaçlanmıştır. Böylelikle verimli bir HIFU terapisi için sıcaklık artışının frekans ile ayarlanabileceği ve en verimli noktanın bulunduğunun modellenmesi ve doğrulanması amaçlanmıştır. Model ve deneyler ex vitro tavuk göğsü kullanarak yapılmıştır. Modelde COMSOL yazılımı kullanılmıştır ve deney ortamı taklit edilmeye çalışılmıştır. 2-Boyutlu aksisimetrik yapı çözülmüştür ve dokuda akustik yayılım ve dokuda ısı yayılımı sonuçları elde edilerek MR termometri verileri ile karşılaştırılmıştır. Deney sonuçlarına göre dokuda ısı yayılım modeli doğrulanmış ve dokuda ısı artışının frekans bağımlılığı gösterilmiştir. Sonuç olarak verimli bir HIFU terapisi için dokudaki sıcaklık artışının önceden tahmin edilebileceği ve sıcaklık artışının akustik frekans ile değiştirilebileceği gösterilmiştir.

Özet (Çeviri)

High Intensity Focused Ultrasound (HIFU) is a promising technology for the treatment of various diseases. The techniques that have been studied mostly include tissue ablation and drug delivery in which application duration and dosage are critical. Tissue ablation requires very high temperatures reached within seconds whereas, drug delivery applications require low temperatures over longer durations. It is also critical to not damage any other tissue than target tissue in both applications (i.e. skin). Therefore, many studies focused on reducing unnecessary heating of the tissue. One of the promising solutions is frequency optimization. Frequency optimization technique, utilizes the frequency of the acoustic pressure depending on the target tissue depth. In literature, there is an analytic solution for this problem; however, this has not been shown experimentally with the calculated solution. This thesis focuses on modeling of a HIFU system with tissue model while using Magnetic Resonance (MR) thermometry for experimental data. So that an efficient HIFU therapy can be delivered to the target knowing how much the tissue is going to be heated. For the experiments, ex vitro chicken breast was used. The model uses COMSOL software and experimental environment can be mimicked properly. The model benefits from 2-D axisymmetric structure of the acoustic and heat problem. The model was then validated using MR thermometry. Frequency dependence was shown both analytically and experimentally. As a result, a HIFU model for tissue heating, which can be used for treatment planning, has been developed and has been shown to predict temperature rise correctly.

Benzer Tezler

  1. Prostat bezine implant edilmiş altın çekirdeklerini ve elektronik portal görüntüleme cihazı kullanarak prostat kanseri hastalarının yeniden pozisyonlandırilması.

    Repositining of prostate cancer patients, using implanted gold seeds into prostate and electronic portal imagin device (EPID).

    NEDRET COŞKUN

    Yüksek Lisans

    Türkçe

    Türkçe

    2008

    OnkolojiEge Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    PROF. DR. SERDAR ÖZKÖK

  2. Karpal tünel sendromunda eswt tedavisinin etkinliği

    Effectiveness of eswt treatment in carpal tunnel syndrome

    REZAN KOÇAK ULUCAKÖY

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2017

    Fiziksel Tıp ve RehabilitasyonSağlık Bilimleri Üniversitesi

    Fiziksel Tıp ve Rehabilitasyon Ana Bilim Dalı

    UZMAN FATMA GÜL YURDAKUL

    PROF. DR. HATİCE BODUR

  3. Yüksek genlikli odaklı ultrason transdüser dizinine verilecek fazların MR görüntüleri yardımı ile oluşturulması

    Computing the beamforming phase delays applied to individual elements of high intensity focused ultasound transducer array based on MR images

    SERKAN AYKUL

    Yüksek Lisans

    Türkçe

    Türkçe

    2013

    Elektrik ve Elektronik MühendisliğiTOBB Ekonomi ve Teknoloji Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    DOÇ. DR. ARİF SANLI ERGÜN

  4. Yüksek genlikli odaklı ultrason uygulamaları için sürüş elektroniği dizini geliştirilmesi

    Development of electronic array drivers for high intensity focused ultrasound applications

    ARDA KOÇAK

    Yüksek Lisans

    Türkçe

    Türkçe

    2013

    Elektrik ve Elektronik MühendisliğiTOBB Ekonomi ve Teknoloji Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    DOÇ. DR. ARİF SANLI ERGÜN

  5. 8 kanallı tümleşik yüksek yeğinlikli odaklı ultrason hüzme şekillendirici sürücü

    Integrated 8 channel high intensity focused ultrasound beamforming driver

    HASAN YETİK

    Yüksek Lisans

    Türkçe

    Türkçe

    2014

    BiyoteknolojiTOBB Ekonomi ve Teknoloji Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    DOÇ. DR. ARİF SANLI ERGÜN