İçme suyu boru hasarlarının detaylı incelenmesi: Christchurch depremi örneği
Assessment of drinking water pipeline damages: Example of Christchurch earthquake
- Tez No: 650838
- Danışmanlar: DR. ÖĞR. ÜYESİ ENGİN NACAROĞLU
- Tez Türü: Yüksek Lisans
- Konular: İnşaat Mühendisliği, Civil Engineering
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2020
- Dil: Türkçe
- Üniversite: Pamukkale Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: İnşaat Mühendisliği Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 99
Özet
popülasyonunun son yüzyıllarda artmasıyla birlikte yol, köprü, kanal ve boru sistemleri gibi mühendislik yapılarına ihtiyaç artmıştır. Özellikle gelişmiş ülkelerde altyapı yoğunluğunun artmış olması ve bu altyapı maliyetleri düşünüldüğünde, altyapı sistemlerinin her türlü doğal olaya karşı hazırlıklı olması gerekmektedir. Canterbury deprem dizisinin en büyük depremlerinden biri olan Mw6,2 büyüklüğündeki 22 Şubat 2011 Christchurch depremi Christchurch'te bulunan içme suyu boru hattı sistemi üzerinde ciddi hasarlara yol açmıştır. Deprem sonrası oluşan boru hasarları altyapı sistemlerinin önemini bir kez daha ortaya koymuştur. Bölgede oluşan boru hasarlarının çok büyük bir kısmı deprem sebebiyle yoğun bir şekilde gözlenen sıvılaşma ve farklı oturmalardan kaynaklanmaktadır. Tez kapsamında 22 Şubat 2011 Christchurch depremi sebebiyle içme suyu boru hatları üzerinde bölgesel analizler ve belirli hasar noktaları için kapsamlı çalışmalar yapılmıştır. Christchurch depremi sonrası bölgede geniş çaplı sıvılaşmalar gözlenmiştir. Uzaktan algılama sistemlerinden olan LiDAR ile deprem öncesi ve sonrası yapılan ölçümler yardımıyla sıvılaşma bölgesinde zeminin yanal yer hareketleri hesaplanarak yatay şekil değiştirmeler elde edilmiştir. Elde edilen yatay şekil değiştirmeler ile bölgede içme suyu boru hattını oluşturan AC, CI ve PVC boru tipleri için hasar ilişkileri ortaya konmuştur. Böylelikle sıvılaşma etkisine maruz kalan boru tiplerinin yanal yayılma etkisi altında davranış farklılıkları incelenmiştir. Ayrıca çalışma kapsamında nümerik analiz yöntemlerinden olan sonlu elemanlar yöntemi ile AC, CI ve PVC boru tipleri üzerinde vaka analizleri yapılmıştır. Christchurch depreminin her bir boru tipi üzerinde neden olduğu sismik aktivitenin borular üzerinde oluşturduğu yer değiştirmeler ve kuvvetler incelenmiştir. Yapılan çalışmalar ile boru tipleri üzerinde hem bölgesel hem de belirli hasar noktalarındaki deprem etkileri boru tipine bağlı olarak ayrıntılı şekilde incelenmiştir.
Özet (Çeviri)
With the increasing in population in recent centuries, the need for engineering structures such as road systems, bridges, canals and pipes has increased. Especially in developed countries, infrastructure density must be increased and infrastructure systems prepared for all types of natural phenomena. One of the biggest earthquakes in the Canterbury earthquake series, the magnitude 6.2, 22 February 2011 Christchurch earthquake caused serious damage to the drinking water pipeline system in Christchurch. Pipe damages after the earthquake once again revealed the importance of infrastructure systems. Most of the pipe damage in the area is caused by liquefaction and different settlements, which are observed intensively due to the earthquake. In this thesis, extensive regional and local studies were conducted on damage to drinking water pipelines resulting from the Christchurch earthquake on February 22, 2011. Extensive liquefaction was observed in the area after the Christchurch earthquake. With the help of LiDAR, which is one of the remote sensing systems, before and after the earthquake horizontal ground movements of the ground were calculated in the liquefaction zone and lateral ground strain were obtained. Damage relationships were determined for the types of AC, CI and PVC pipes that make up the drinking water pipeline in the area with the obtained lateral ground strain. Thus, behavioral differences under the effect of lateral spreading of pipe types exposed to liquefaction were investigated. Moreover, in this study, case analyzes were performed on AC, CI and PVC pipe types by finite element method, which is one of the numerical analysis methods. The deformations and forces caused by the seismic activity caused by the Christchurch earthquake were examined on each type of pipe. With this conducted study, the earthquake effects on the pipe types at both regional and specific damage points were examined in detail depending on the pipe type.
Benzer Tezler
- İstanbul su şebekelerinin sismik analizi
Seismic evaluation of water transmission system in Istanbul
GÖKHAN KILIÇ
Yüksek Lisans
Türkçe
2010
Deprem MühendisliğiGebze Yüksek Teknoloji EnstitüsüDeprem ve Yapı Bilimleri Ana Bilim Dalı
PROF. DR. BİLGE SİYAHİ
- Pipeline damage assessment through Monte Carlo simulation
Boru hatları hasarlarının Monte Carlo simülasyonu ile değerlendirilmesi
ALİ OSMAN BİNGÖL
Yüksek Lisans
İngilizce
2021
Deprem MühendisliğiBoğaziçi ÜniversitesiDeprem Mühendisliği Ana Bilim Dalı
DOÇ. DR. UFUK HANCILAR
- Kocaeli ili Dilovası ilçesi gömülü boru hatlarının deprem risklerinin belirlenmesi
Determination of earthquake risks of buried pipelines in Dilovasi district of Kocaeli province
HALİL TURGUT
Yüksek Lisans
Türkçe
2024
Deprem MühendisliğiGebze Teknik Üniversitesiİnşaat Mühendisliği Ana Bilim Dalı
DR. ÖĞR. ÜYESİ FATMA İLKNUR KARA
- Erzurum ili Horasan ilçesi içme suyu şebeke hattının farklı boru tipleri için netcad programıyla tasarımı ve maliyet analizi
Design and cost analysis of drinking water network line of Erzurum province Horasan district for different pipe types with netcad program
FATİH ATAKUL
Yüksek Lisans
Türkçe
2019
İnşaat MühendisliğiBayburt Üniversitesiİnşaat Mühendisliği Ana Bilim Dalı
DR. ÖĞR. ÜYESİ GÖKÇEN ERYILMAZ TÜRKKAN
- İsale hatlarında deprem riski: yöntem geliştirme ve istanbul için bir uygulama
Seismic risk of water mains : method development and application to istanbul
GÖKHAN ÇALIM
Doktora
Türkçe
2019
Deprem Mühendisliğiİstanbul Teknik Üniversitesiİnşaat Mühendisliği Ana Bilim Dalı
PROF. DR. FATMA GÜLTEN GÜLAY
YRD. DOÇ. DR. İHSAN ENGİN BAL