Koklear implant uyarım parametrelerindeki değişimin kortikal ve spektral-temporal çözünürlüklere etkisinin incelenmesi

Investigation of the effect of changes in cochlear implant stimulation parameters on cortical and spectral-temporal resolutions

  1. Tez No: 837146
  2. Yazar: RIŞVAN DENİZ
  3. Danışmanlar: DR. ÖĞR. ÜYESİ EYYUP KARA
  4. Tez Türü: Doktora
  5. Konular: Kulak Burun ve Boğaz, Otorhinolaryngology (Ear-Nose-Throat)
  6. Anahtar Kelimeler: Koklea hastalıkları, Koklear implantlar, Kulak hastalıkları, Malformasyonlar, İç kulak, Cochlear diseases, Cochlear implants, Ear diseases, Abnormalities, Ear-inner
  7. Yıl: 2023
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi-Cerrahpaşa
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Odyoloji Ana Bilim Dalı
  12. Bilim Dalı: Odyoloji ve Konuşma Bozuklukları Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

İç kulak malformasyonu olan koklear implant olan kullanıcılarında, en sık şikâyet edilen sorun işitsel olmayan rahatsız edici uyarımlardır. Bu rahatsızlık için farklı programlama teknikleri uygulanabilmektedir. Yeni bir uyarım modu olan trifazik elektriksel uyarım, fasiyal sinir uyarımı olan hastalarda sıklıkla kullanılmakla birlikte, iç kulak malformasyonu olan koklear implant kullanıcılarındaki spektral-temporal çözünürlük ve kortikal etkisine yönelik daha önce çalışma yapılmamıştır. Bu nedenle çalışmamızdaki amacımız, iç kulak malformasyonu olan kişilerde trifazik elektriksel uyarımın spektral-temporal çözünürlük ve işitsel kortikal etkisini değerlendirmektir. Çalışmamıza, 20 normal iç kulak anatomisi olan koklear implant kullanıcısı ve 20 iç kulak malformasyonu olan koklear implant kullanıcısı birey dahil edilmiştir. Hastalara hem bifazik elektriksel uyarım hem de trifazik elektriksel uyarım ile kaydedilen programlarda, gürültüde ayırt etme testleri, elektrofizyolojik işitsel kortikal testler, spektral-temporal çözünürlük değerlendirmeleri yapılmıştır. Veriler incelendiğinde, iç kulak malformasyonu olan koklear implant kullanıcısı bireylerde trifazik elektriksel uyarımda bifazik uyarıma göre rahat duyma ve eşik seviyelerinde apeks, medial ve bazal bölgede daha yüksek elde edilmiştir(p<0.05). Benzer şekilde konuşma testleri değerleri de iç kulak malformasyonu olan grupta trifazik elektriksel uyarımda, bifazik uyarıma göre anlamlı derecede daha iyi elde edilmiştir(p<0.05). Ayrıca iç kulak malformasyonu olan koklear implant kullanıcısı bireylerde, trifazik elektriksel uyarımda bifazik uyarıma göre spektral-temporal çözünürlük, , gürültüde ayırt etme testi ve işitsel kortikal testlerin amplitüd ölçümlerinde anlamlı derecede daha iyi sonuçlar (p<0.05) gözlenmiştir. Elde edilen verilere göre iç kulak malformasyonu olan grupta, trifazik elektriksel uyarım ile spektral ve temporal çözünürlüğün arttığı, daha iyi gürültüde ayırt etme ve daha iyi işitsel kortikal yanıtlar gözlenmiştir. Bu sonuçlara göre, trifazik elektriksel uyarımın iç kulak malformasyonu olan koklear implant kullanıcısı bireylerde programlama sürecine dahil edilmesinin kullanıcılara fayda sağlayacağı düşünülmektedir.

Özet (Çeviri)

The most frequently complained problem in cochlear implant users with inner ear malformations is disturbing non-auditory stimulation. Different programming techniques can be applied for this disorder. Although triphasic electrical stimulation, a new stimulation mode, is frequently used in patients with facial nerve stimulation, no previous study has been conducted on its spectral-temporal resolution and cortical effect in cochlear implant users with inner ear malformations. Therefore, aim in this study was to evaluate the spectral-temporal resolution and auditory cortical effect of triphasic electrical stimulation in people with inner ear malformations. Our study included 20 cochlear implant users with normal inner ear anatomy and 20 cochlear implant users with inner ear malformations. The patients underwent discrimination tests in noise, electrophysiological auditory cortical tests, and spectral-temporal resolution evaluations in programs recorded with both biphasic electrical stimulation and triphasic electrical stimulation. When the data were examined, most comfortable level and threshold levels were obtained in the apex, medial and basal regions in triphasic electrical stimulation compared to biphasic stimulation in cochlear implant users with inner ear malformations (p<0.05). Similarly, speech audiometry test values were obtained significantly better in the group with inner ear malformation in triphasic electrical stimulation than in biphasic stimulation (p<0.05). Additionally, in cochlear implant users with inner ear malformation, significantly better results (p<0.05) were observed in spectral-temporal resolution, matrix sentences test and amplitude measurements of auditory cortical tests in triphasic electrical stimulation compared to biphasic stimulation. According to the data obtained, in the group with inner ear malformation, increased spectral and temporal resolution, better discrimination in noise and better auditory cortical responses were observed with triphasic electrical stimulation. According to these results, it is thought that including triphasic electrical stimulation in the programming process of cochlear implant users with inner ear malformations will benefit the users.

Benzer Tezler

  1. Bitki gelişiminde kirli suların etkisi üzerine bir ön araştırma

    Başlık çevirisi yok

    SEVİL ÖZCAN

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Ege Üniversitesi

    Botanik Ana Bilim Dalı

    Yükleniyor...

  2. Türkiye linyit ve taşkömürlerinden metalurjik amaçla karma kok üretimi

    Başlık çevirisi yok

    HASAN FERİT BERK

    Doktora

    Türkçe

    Türkçe

    1984

    İstanbul Teknik Üniversitesi

    Yükleniyor...

  3. Liquidambar orientalis mill (sığla ağacı)'in morfolojik ve palinolojik özellikleri üzerine araştırmalar

    Studies on the morphological and palynological characteristics of liquidambar orientalis mill. in Turkey

    ASUMAN GÜNGÖRDÜ

    Doktora

    Türkçe

    Türkçe

    1986

    İstanbul Üniversitesi

    Orman Botaniği Bilim Dalı

    Yükleniyor...

  4. Sahil çamı ve kızılçamında tohum büyüklüğü ve ağırlığının çimlenme yüzdesine, fidan boyuna, fidan kalitesine etkisi

    Başlık çevirisi yok

    ŞÜKRAN GÖKDEMİR

    Yüksek Lisans

    Türkçe

    Türkçe

    1988

    Karadeniz Teknik Üniversitesi

    Orman Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  5. Ekstrakte edilen kömürlerin tutuşma sıcaklıklarının belirlenmesi ve gözenekli yapısının gaz adsorpsiyonu ile incelenmesi

    The Determination of ignition temperatures of the extracted coals and the investigation of their porous structures by the gas adsorption method

    ZARİFE CANEL

    Yüksek Lisans

    Türkçe

    Türkçe

    1988

    Ankara Üniversitesi

    Kimya Ana Bilim Dalı

    Yükleniyor...