Geri Dön

Hibrit derin öğrenme modeli kullanılarak PV panellerde kirlenme oranı tespiti

Detection of PV panel soiling rates using a hybrid deep learning model

  1. Tez No: 1027755
  2. Yazar: İBRAHİM İLHAN
  3. Danışmanlar: DOÇ. DR. AHMET KÜÇÜKER
  4. Tez Türü: Yüksek Lisans
  5. Konular: Elektrik ve Elektronik Mühendisliği, Electrical and Electronics Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: Sakarya Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Elektrik-Elektronik Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Elektrik Mühendisliği Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Fotovoltaik (PV) paneller, yenilenebilir enerji kaynakları arasında önemli bir yere sahip olan ve en basit deyişle güneş ışığını elektrik enerjisine dönüştüren sistemlerdir. Günümüzde temiz enerjiye olan ihtiyacın artmasıyla birlikte PV sistemlerin kullanımı hızla yaygınlaşmaktadır. Ancak, saha koşullarında çevresel faktörlerin etkisiyle zaman içinde panel yüzeylerinde toz, kir ve diğer yabancı maddeler birikerek ışık geçirgenliği azalmakta ve enerji üretim verimliliği ciddi bir şekilde düşmektedir. PV panellerin optimum verimde çalışabilmesi için düzenli olarak izlenmesi ve bakımlarının yapılması gerekmektedir. Özellikle büyük ölçekli güneş enerji santrallerinde manuel denetimler ve temizlik işlemleri hem yüksek maliyetli ve hem de zaman alıcı olmaktadır. Manuel denetimlerin yarattığı zorlukları aşmak için kirlilik tespitinin daha doğru, hızlı ve otomatik bir şekilde gerçekleştirilmesine olanak tanıyan yapay sinir ağları (YSA) tabanlı yenilikçi çözümler büyük bir gereklilik haline gelmiştir. Çalışmada, PV panellerde meydana gelen kirliliği yüksek doğrulukla tespit edebilen hibrit bir model önerilmektedir. Önerilen model; Yerel İkili Desenler (Local Binary Patterns, LBP), Görüş Transformatörleri (Vision Transformer, ViT) ve Konvolüsyonel Sinir Ağları (Convolutional Neural Networks, CNN) olmak üzere üç aşamalı bir mimari üzerine inşa edilmiştir. İlk olarak, LBP yöntemi kullanılarak panel yüzeylerindeki dokusal değişiklikler analiz edilmiştir. LBP, özellikle küçük ölçekli dokusal değişimleri tespit etme yeteneği sayesinde, düşük yoğunluktaki toz birikimlerinin tespitinde etkili bir öznitelik çıkarım yöntemi olarak öne çıkmaktadır. Geleneksel görüntü işleme yöntemleri, ışık yoğunluğu farklılıklarını temel alarak çalıştığından, ince toz birikintileri gibi zor algılanan değişiklikleri belirlemekte yetersiz kalsa da LBP, doğrudan dokusal farklılıkları temel aldığı için ince kirliliklerin daha hassas bir şekilde tespit edilmesini sağlamaktadır. LBP kullanılarak yapılan ön işleme adımı bittikten sonra, ViT kullanılarak LBP ile çıkarılan öznitelikler daha detaylı bir şekilde analiz edilmiştir. ViT, görüntülerdeki uzun menzilli bağıntıları öğrenerek, yüzeydeki kirlilik dağılımını doğru bir şekilde belirlemekte ve geleneksel evrişim tabanlı modellerin sadece yerel özelliklere odaklanma problemini ortadan kaldırmaktadır. ViT' nin küresel bağlamı dikkate alarak çalışması, özellikle homojen olmayan toz dağılımlarının tespitinde büyük bir avantaj sağlamaktadır. ViT tarafından çıkarılan öznitelikler CNN tabanlı bir sınıflandırıcı kullanılarak analiz edilmiş ve panellerin temiz veya kirli olup olmadığı yüksek doğruluk oranlarıyla belirlenmiştir. CNN modelleri, nesne tanıma ve görüntü sınıflandırma problemlerinde oldukça başarılı bir yapıya sahip olup, PV panellerin yüzey dokularındaki değişiklikleri hassas bir şekilde algılayarak panellerin kirlilik durumunu belirlemektedir. Önerilen modelin başarısını değerlendirmek için iki farklı veri seti üzerinde kapsamlı deneyler gerçekleştirilmiştir. Birinci veri seti, farklı çevresel koşullarda çekilmiş ve arka planında çatı, çimen gibi sınıflandırmayı zorlaştırıcı etkenlerin olduğu PV panel görüntülerinden oluşmaktadır. İkinci veri seti ise, literatürde yaygın olarak kullanılan ve PV panellerdeki kirlilik tespitinde referans niteliği taşıyan Deep Solar Eye veri setidir. Model, iki veri seti üzerinde de bağımsız olarak eğitilip test edilmiş, ayrıca modelin genelleme yeteneğini değerlendirmek amacıyla çapraz eğitim yöntemi de uygulanmıştır. Eğitim sürecinde modelin en iyi performansı elde etmesi için Optuna algoritması ile hiperparametre optimizasyonu gerçekleştirilmiş; modelin öğrenme oranı, katman sayısı ve aktivasyon fonksiyonları gibi parametreleri en uygun hale getirilerek doğruluk oranlarının artırılması sağlanmıştır. Deneysel analizler, önerilen modelin mevcut görüntü işleme ve derin öğrenme tabanlı yaklaşımlara kıyasla önemli avantajlar sunduğunu ortaya koymuştur. Önerilen model, ilk veri setiyle eğitilip test edildiğinde model %95.7 doğruluk oranına ulaşmış, temiz panelleri %96.9, kirli panelleri ise %98.1 oranında doğru tespit etmiştir. Deep Solar Eye veri setinde ise doğruluk oranı %99.5' e ulaşmış, temiz paneller için %99.3, kirli paneller için ise %99.8 doğruluk sağlanmıştır. Daha sonra önerilen model mimarisindeki yapıların birleştirilmesinin gerekli olup olmadığının görülmesi için veri seti 1 ilk olarak ön işleme yapılmadan yani LBP kullanılmadan sonrasında LBP kullanılarak CNN, ViT ve LBPViTCNN modelleriyle eğitilip test edilmiştir. Test sonucunda CNN ve ViT modellerinde ön işleme kullanılmadığı takdirde LBPVİTCNN modelinin diğer modellere göre minimum %10 daha doğru sonuç verdiği; ön işleme yapıldığında ise CNN ve ViT modellerinin veri setini öğrenmede güçlük çektiği, LBPViTCNN modelinin diğer modellerden minimum %28 daha doğru sonuç verdiği gözlemlenmiştir. Aynı şekilde Deep Solar Eye veri seti ön işleme yapılmadan yani LBP kullanılmadan sonrasında LBP kullanılarak CNN, ViT ve LBPViTCNN modelleriyle eğitilip test edilmiştir. Test sonucunda CNN ve ViT modellerinde ön işleme kullanılmadığı takdirde LBVİTCNN modelinin diğer modellere göre minimum %0.4 daha doğru sonuç verdiği; ön işleme yapıldığında ise CNN ve ViT modellerinin veri setini öğrenmede güçlük çektiği, LBPViTCNN modelinin diğer modellerden minimum %50 daha doğru sonuç verdiği gözlemlenmiştir. Önerilen modelin hem iki farklı veri setiyle eğitilip test edilmesi hem de içinde barındırdığı yapılarla ön işlemeli ve ön işlemesiz olarak ayrı ayrı test edilmesi hem veri seti seçiminin önemini, modelin gerçek zamanlı kullanımının uygunluğunu hem de model içinde kullanılan yapıların beraber kullanılmasının uygun olup olmadığını göstermiştir. Daha sonra önerilen LBPViTCNN modelini daha geniş bir perspektiften değerlendirebilmek amacıyla; literatürde yaygın olarak kullanılan VGG16, ResNet, DenseNet121, EfficientNetB0 ve InceptionV3 gibi derin öğrenme modelleriyle karşılaştırmalar yapılmıştır. Sonuçlar, önerilen modelin iki farklı veri seti eğitiminde ve testinde yüksek doğruluk oranına ulaştığını ve ince dokusal detayları yakalamada üstün bir performans sergilediğini göstermiştir. Önerilen model, veri setlerinin kendi içinde eğitilip test edilmesinde başarılı bir sonuç vermiş olsa da modelin farklı veri setlerindeki performansını değerlendirmek ve piyasada uygulanabilirliğini görmek amacıyla çapraz testler gerçekleştirilmiştir. İlk çapraz testte, birinci veri setiyle eğitilen model, Deep Solar Eye veri seti üzerinde test edilmiş ve %90.15 doğruluk oranı elde edilmiştir. Ulaşılan doğruluk oranı, modelin farklı veri kümelerinde de başarılı bir şekilde çalışabildiğini ve öğrenilen özelliklerin yüksek genelleme kapasitesine sahip olduğunu göstermektedir. İkinci çapraz testte ise, Deep Solar Eye veri setiyle eğitilen model, birinci veri seti üzerinde test edilerek %65.2 doğruluk oranına ulaşmıştır. Ulaşılan doğruluk oranı, modelin farklı çevresel koşullara ve veri dağılımlarına başarılı bir şekilde uyum sağlayabildiğini fakat sadece arka plan görsellerinden arındırılmış Deep Solar Eye veri setiyle eğitilen bir modelin endüstriyel kullanıma uygun olmadığını göstermiştir. Çalışmada elde edilen sonuçlara göre, PV panellerde kirlilik tespitini yapay sinir ağı tabanlı yeni nesil yöntemlerle ele alarak, enerji üretim verimliliğinin artırılmasına yönelik önemli bir katkı sunmaktadır. Geliştirilen model, geleneksel yöntemlerle tespit edilmesi güç olan ince toz birikimlerini yüksek doğruluk oranıyla belirleyerek bakım süreçlerini daha verimli hale getirmekte ve PV sistemlerin performans kaybını minimuma düşürmektedir.

Özet (Çeviri)

Photovoltaic (PV) panels are systems that play a significant role among renewable energy sources and, in the simplest terms, convert sunlight into electrical energy. With the increasing need for clean energy today, the use of PV systems is rapidly becoming widespread. However, over time, environmental factors in the field cause dust, dirt, and other foreign matter to accumulate on the panel surfaces, reducing light transmittance and significantly decreasing energy production efficiency. PV panels must be regularly monitored and maintained to operate at optimal efficiency. Manual inspections and cleaning operations, especially in large-scale solar power plants, are both costly and time-consuming. To overcome the difficulties posed by manual inspections, innovative solutions based on artificial neural networks (ANNs), which enable more accurate, faster, and automated contamination detection, have become a necessity. The study proposes a hybrid model capable of detecting contamination on PV panels with high accuracy. The proposed model is built on a three-stage architecture consisting of Local Binary Patterns (LBP), Vision Transformers (ViT), and Convolutional Neural Networks (CNN). First, textural changes on the panel surfaces were analyzed using the LBP method. LBP stands out as an effective feature extraction method for detecting low-density dust accumulation, thanks to its ability to detect small-scale textural changes. While traditional image processing methods, which operate based on light intensity differences, are insufficient for identifying difficult-to-detect changes such as fine dust accumulation, LBP enables more accurate detection of fine contamination because it is based directly on textural differences. After the preprocessing step using LBP was completed, the features extracted with LBP were analyzed in more detail using ViT. By learning long-range correlations in images, ViT accurately determines the distribution of surface contamination and eliminates the problem of traditional convolution-based models focusing only on local features. ViT's ability to work with global context provides a significant advantage, especially in detecting non-homogeneous dust distributions. The features extracted by ViT were analyzed using a CNN-based classifier, and the clean or dirty status of the panels was determined with high accuracy rates. CNN models have a highly successful structure in object recognition and image classification problems, accurately detecting changes in the surface textures of PV panels to determine their contamination status. To evaluate the performance of the proposed model, comprehensive experiments were conducted on two different datasets. The first dataset consists of PV panel images taken under different environmental conditions, including backgrounds with roofs and grass, which introduce classification challenges. The second dataset is the widely used Deep Solar Eye dataset, which serves as a reference for contamination detection in PV panels. The model was trained and tested independently on both datasets, and cross-validation was also performed to assess its generalization capability. To achieve optimal model performance, hyperparameter optimization was conducted using the Optuna algorithm, fine-tuning parameters such as learning rate, number of layers, and activation functions to maximize accuracy. Experimental analyses have demonstrated that the proposed model offers significant advantages over existing image processing and deep learning-based approaches. When trained and tested on the first dataset, the model achieved an accuracy rate of 95.7%, correctly identifying clean panels at 96.9% and contaminated panels at 98.1%. On the Deep Solar Eye dataset, the accuracy rate reached 99.5%, with 99.3% accuracy for clean panels and 99.8% for contaminated panels. To assess the necessity of combining different components in the proposed model architecture, Dataset 1 was first tested without preprocessing (i.e., without LBP) and then tested again with LBP using CNN, ViT, and the hybrid LBPViTCNN model. The results showed that when preprocessing was not used, the LBPViTCNN model outperformed CNN and ViT by at least 10%. When preprocessing was applied, CNN and ViT struggled to learn from the dataset, while the LBPViTCNN model achieved at least 28% higher accuracy compared to other models. Similarly, the Deep Solar Eye dataset was evaluated both with and without preprocessing using CNN, ViT, and LBPViTCNN models. The results indicated that without preprocessing, the LBPViTCNN model was at least 0.4% more accurate than the other models. When preprocessing was applied, CNN and ViT encountered difficulties in learning from the dataset, whereas the LBPViTCNN model demonstrated a minimum of 50% higher accuracy than the other models. The evaluation of the proposed model through training and testing on two different datasets, along with separate assessments with and without preprocessing, highlights the importance of dataset selection, the model' s suitability for real-time applications, and the necessity of using multiple components together. Furthermore, to assess the LBPViTCNN model from a broader perspective, comparisons were made with widely used deep learning models such as VGG16, ResNet, DenseNet121, EfficientNetB0, and InceptionV3. The results indicate that the proposed model achieved high accuracy in both datasets and exhibited superior performance in capturing fine textural details. Although the proposed model demonstrated successful results when trained and tested within the same dataset, cross-tests were conducted to evaluate its performance on different datasets and assess its practical applicability. In the first cross-test, the model trained on Dataset 1 was tested on the Deep Solar Eye dataset, achieving an accuracy of 90.15%. This accuracy level demonstrates that the model can perform well across different datasets and that the learned features have high generalization capacity. In the second cross-test, the model trained on the Deep Solar Eye dataset was tested on Dataset 1, achieving an accuracy of 65.2%. This result indicates that while the model adapts well to different environmental conditions and data distributions, training solely on the background-free Deep Solar Eye dataset does not make it suitable for industrial applications. According to the findings of the study, by addressing the detection of contamination on PV panels using new-generation methods based on artificial neural networks, it makes a significant contribution to improving energy production efficiency. The developed model identifies fine dust accumulations, which are difficult to detect using traditional methods, with a high degree of accuracy, making maintenance processes more efficient and minimizing performance loss in PV systems.

Benzer Tezler

  1. Detection of solar panel defects in electroluminescence images using deep learning

    Derin öğrenme kullanılarak elektrolüminesans görüntülerinde güneş paneli hatalarının tespiti

    BAHAA SALIH MANDEEL

    Yüksek Lisans

    İngilizce

    İngilizce

    2024

    Karabük Üniversitesi

    Bilgisayar Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  2. Heuristic vectorized learning method based PV forecasting by using image recognition-based sky camera integration within sensor set

    Görüntü tanıma tabanlı gökyüzü kamerası entegrasyonunu kullanarak sezgisel vektörize öğrenme yöntemine dayalı PV tahmini

    LEVENT YAVUZ

    Doktora

    İngilizce

    İngilizce

    2023

    Abdullah Gül Üniversitesi

    Elektrik ve Bilgisayar Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  3. Hibrit sistemlerin ekonomik olarak sürdürülebilirlik analizi

    Economical sustainability analysis of hybrid systems

    CEREN CEYLAN

    Doktora

    Türkçe

    Türkçe

    2025

    Yıldız Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  4. Fotovoltaik sistemlerde arıza ve hata tespiti için yapay zekâ tabanlı karar destek sistemi geliştirilmesi ve uygulaması

    Development and implementation of an artificial intelligence-based decision support system for fault detection and diagnosis in photovoltaic systems

    MUHAMMED BUĞRAHAN KAYA

    Yüksek Lisans

    Türkçe

    Türkçe

    2026

    Erzincan Binali Yıldırım Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  5. Forecasting solar irradiance using deep learning and big data analytics techniques in Sakarya and Damascus

    Sakarya ve Şam'da derin öğrenme ve büyük veri analitiği teknikleri kullanılarak güneş ışınımının tahmini

    MARYA ALHAJMOHAMMADOTHMAN

    Yüksek Lisans

    İngilizce

    İngilizce

    2026

    Sakarya Üniversitesi

    Elektrik ve Elektronik Mühendisliği Ana Bilim Dalı

    Yükleniyor...