Muğla bölgesinde fotovoltaik-termal sistem destekli atık su arıtımının termoekonomik analizi ve optimizasyonu
Thermoeconomic analysis and optimization of photovoltaic-thermal system supported waste water treatment in Muğla region
- Tez No: 1027935
- Danışmanlar: DR. ÖĞR. ÜYESİ VOLKAN RAMAZAN AKKAYA
- Tez Türü: Yüksek Lisans
- Konular: Enerji, Energy
- Anahtar Kelimeler: Elektrik enerjisi, Güneş, Yeşil enerji, Electrical energy, Solar, Green energy
- Yıl: 2026
- Dil: Türkçe
- Üniversite: Muğla Sıtkı Koçman Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Enerji Sistemleri Mühendisliği Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Bu tezde Yalıkavak Atık Su Arıtma Tesisi (AAT) için fotovoltaik (PV) ve fotovoltaik-termal (PV-T) sistem seçenekleri saatlik elektrik bilançosu, çamur kısmi kurutma katkısı, finansal performans, elektrik kaynaklı CO₂ azaltımı ve çok amaçlı optimizasyon çerçevesinde değerlendirilmiştir. Çalışmanın temel amacı, PV-T sistemin PV referansına göre daha fazla elektrik ürettiğini göstermek değil; aynı elektriksel kapasite altında PV-T sistemden elde edilebilecek düşük sıcaklıklı ısının dekantör sonrası çamurun kısmi kurutma talebine bağlanarak ek bir işletme faydası üretip üretemediğini incelemektir. Modelde PV ve PV-T sistemlerin elektrik üretimi aynı PVWatts üretimiyle temsil edilmiş, PV-T sistemin ayırt edici katkısı ise faydalı ısı ve buna bağlı yaş çamur kütle azaltımı üzerinden değerlendirilmiştir. Saatlik elektrik yükü, ölçülmüş SCADA verisi bulunmadığından sentetik yük profiliyle kurulmuş; güneş üretimi Bodrum tipik meteorolojik yıl verisi ve PySAM/PVWatts V7 modeliyle hesaplanmıştır. Finansal değerlendirmede NPV, proje ömrü boyunca oluşan net nakit akışlarının bugünkü değerinden ilk yatırım maliyetinin çıkarılmasıyla hesaplanmış; şebekeye verilen ihtiyaç fazlası elektrik ana senaryoda gelir olarak değerlendirilmemiştir. 540 kWp baz PV-T senaryosunda yıllık 975,7 MWh elektrik üretimi, 469,3 MWh öz tüketim ve 211,2 ton/yıl elektrik kaynaklı CO₂ azaltımı hesaplanmıştır. Aynı senaryoda PV-T sistemi 677,6 MWh/yıl faydalı ısı sağlamış, 752,8 ton/yıl su uzaklaştırma eşdeğeri üretmiş ve hedeflenen kısmi kurutma ihtiyacının %55,0'ını karşılamıştır. Çok amaçlı NSGA-II optimizasyonu sonucunda 48 Pareto-optimal çözüm elde edilmiştir. Maksimum NPV çözümü 321,0 kWp kapasitede 423.376 USD NPV ve 188,3 ton/yıl CO₂ azaltımı sağlarken, maksimum CO₂ azaltımı çözümü 720,0 kWp kapasitede 223,6 ton/yıl CO₂ azaltımı ve 151.476 USD NPV üretmiştir. Dengeli çözüm ise 522,4 kWp kapasitede 342.464 USD NPV ve 211,8 ton/yıl CO₂ azaltımı sağlamıştır. Yirmi bağımsız başlangıç koşulu ile yapılan algoritmik dayanıklılık kontrolünde hiperhacim değişim katsayısı %0,012 düzeyinde kalmış ve Pareto cephesinin rastlantısal başlangıç koşullarına karşı kararlı olduğu görülmüştür. Sonuçlar, PV-T sistemin Yalıkavak AAT için değerinin yalnızca güneş elektriği üretiminden değil, saatlik öz tüketim, çamur hattında kullanılabilir faydalı ısı, trafo kapasitesi, kullanılabilir alan ve fazla elektrik değerlendirme koşullarının birlikte ele alınmasından kaynaklandığını göstermektedir. Finansal performans ve düşük altyapı riski öncelikliyse yaklaşık 320 kWp düzeyindeki çözüm; çevresel azaltım ve çamur hattı katkısı da karar ölçütü ise saha doğrulaması koşuluyla yaklaşık 520 kWp düzeyindeki dengeli çözüm daha savunulabilir görünmektedir.
Özet (Çeviri)
In this thesis, photovoltaic (PV) and photovoltaic-thermal (PV-T) system options for the Yalıkavak Waste Water Treatment Plant were evaluated through an hourly electricity balance, partial sludge drying contribution, financial performance, electricity-related CO₂ reduction, and multi-objective optimization. The main objective of the study is not to show that the PV-T system produces more electricity than the PV reference case, but to examine whether low-temperature heat obtained from a PV-T system at the same electrical capacity can create an additional operational benefit when linked to the partial drying demand of dewatered sludge. In the model, the electricity generation of PV and PV-T systems was represented by the same PVWatts output, while the distinctive contribution of the PV-T system was evaluated through useful heat and the resulting reduction in wet sludge mass. Since measured SCADA data were not available, the hourly electricity demand was represented by a synthetic load profile. Solar electricity generation was calculated using Bodrum typical meteorological year data and the PySAM/PVWatts V7 model. In the financial assessment, NPV was calculated as the present value of net cash flows over the project lifetime minus the initial investment cost. Excess electricity exported to the grid was not monetized in the main financial scenario. For the 540 kWp base PV-T scenario, annual electricity generation, self-consumption, and electricity-related CO₂ reduction were calculated as 975.7 MWh, 469.3 MWh, and 211.2 t/year, respectively. In the same scenario, the PV-T system supplied 677.6 MWh/year of useful heat, provided a water removal equivalent of 752.8 t/year, and met 55.0% of the target partial drying demand. The multi-objective NSGA-II optimization produced 48 Pareto-optimal solutions. The maximum NPV solution occurred at 321.0 kWp, with an NPV of USD 423,376 and a CO₂ reduction of 188.3 t/year. The maximum CO₂ reduction solution occurred at 720.0 kWp, with a CO₂ reduction of 223.6 t/year and an NPV of USD 151,476. The balanced solution occurred at 522.4 kWp, with an NPV of USD 342,464 and a CO₂ reduction of 211.8 t/year. The algorithmic robustness check using 20 independent initial conditions resulted in a hypervolume coefficient of variation of 0.012%, indicating that the Pareto front was stable against random initial conditions. The results show that the value of a PV-T system for the Yalıkavak Wastewater Treatment Plant depends not only on solar electricity generation, but also on hourly self-consumption, usable thermal demand in the sludge line, transformer capacity, available installation area, and the treatment of excess electricity. If financial performance and low infrastructure risk are prioritized, the solution around 320 kWp appears more defensible. If environmental reduction and sludge-line contribution are also considered, the balanced solution around 520 kWp becomes a stronger candidate, provided that site area and grid connection capacity are verified.
Benzer Tezler
- Ege bölgesi keçi liflerinin bazı önemli fiziksel, kimyasal özellikleri ve değerlendirme imkanları
Başlık çevirisi yok
NİLÜFER ERDEM
- Dokuz Eylül Üniversitesi Muğla İşletmecilik Yüksek Okulu 1983-1984 öğretim yılı öğrencileriyle ilgili araştırma
Başlık çevirisi yok
BELKIS YEDİYILDIZ
- Muğla yöresindeki genç kızılçam (pinus prutia Ten) meşcerelerinde ilk aralama müdahaleleri üzerine silvikültürel araştırmalar
Recherches silvicoles sur les traitements de premiere eclaircie dans les peuplements jeunes de pin brutia de la region de Muğla
BURHAN CEYLAN
- Üç girişli veri tablolarının ana bileşenli faktör analizi yöntemiyle incelenmesi ve bir uygulama
Başlık çevirisi yok
EYÜP SABRİ TÜRKER