Gaz türbini kanat içi rib türbülatörlü soğutma kanallarında film soğutma deliği konumunun ısıl-akış performansına etkilerinin sayısal olarak incelenmesi

A numerical investigation of the effects of film cooling hole location on thermal-flow performance for rib-turbulated cooling channels in gas turbine blade

  1. Tez No: 1030397
  2. Yazar: SAMET POLAT
  3. Danışmanlar: PROF. DR. YAHYA DOĞU
  4. Tez Türü: Yüksek Lisans
  5. Konular: Makine Mühendisliği, Havacılık ve Uzay Mühendisliği, Mechanical Engineering, Aeronautical Engineering
  6. Anahtar Kelimeler: Bilgisayar destekli termal analiz, Gaz türbinli motorlar, Hesaplamalı akışkanlar dinamiği (HAD), Computer aided thermal analysis, Gas turbine engines, Computational fluid dynamics (HAD)
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: Kırıkkale Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Havacılık ve güç üretiminde kullanılan gaz türbinli motorlarda türbin kanatlarının iç ve dış soğutması; türbin giriş sıcaklığı, verimlilik ve güç çıkışında iyileştirme sağlamak için kritik bir teknolojidir. Kanat iç soğutmasında çubuk engel (rib) yerleştirilen kanallar uygulanırken, dış soğutmada film soğutma kullanılmaktadır. İç soğutma kanalındaki riblerin arasına dış soğutma için konumlanan film soğutma delikleri kanal içindeki ısıl-akış davranışını etkilemektedir. Bu tez çalışmasında, film delikli ve ribli kanal uygulamasının akış ve ısı transferi üzerindeki etkileri HAD (Hesaplamalı Akışkanlar Dinamiği) analizleri ile incelenmiştir. Kanat içi soğutma kanalı, karşılıklı iki yüzeyinde de ribler bulunan kare kesitli bir kanaldır. Kanal içine akışa dik yönde yerleştirilen riblerin blokaj oranı (e/H) 0.0625 ve hatve oranı (P/e) 10'dur. Kanal Reynolds sayısı referans olarak 21800 olarak alınmıştır. Kanalın ribli ve düz yüzeylerine üniform ısı akısı uygulanmıştır. Film soğutma delikleri, riblerin arasında 5 farklı konuma yerleştirilerek oluşan ısı transferi incelenmiştir. Kanaldaki kütlesel debinin genel bir değer olarak %15'inin film soğutma deliklerine yöneldiği tanımlanmıştır. HAD analizlerinde, rib türbülatör uygulamaları için test verileriyle yakın örtüşen ve bir RANS modeli olan v2f türbülans modeli kullanılmıştır. Analiz sonuçları, kanal duvarlarındaki ortalama Stanton sayısı ve sürtünme faktörü hesaplanarak değerlendirilmiştir. Ayrıca, ribler ve delikler etrafındaki bölgesel akış oluşumları ve sıcaklık dağılımları da değerlendirilmiştir. Genel olarak; film deliklerinin ısı transferini artırdığı ve sürtünme faktörünü düşürdüğü görülmüştür. Ayrıca deliklerin eksenel ve yanal konumlarının kanal performansı üzerinde önemli etkileye sahip olduğu belirlenmiştir. Eksenel yönde Ön-Merkez ve Orta-Merkez konumları en yüksek ortalama ısı transferini sağlarken, Arka-Merkez konumunda erken tahliye kaynaklı bölgesel sıcak noktalar gözlenmiştir. Yanal eksende ise deliğin kanal merkezinden köşeye doğru kaydırılması, tabandaki ortalama ısıl performansı belirgin ölçüde değiştirmemekle birlikte; yan duvarlar arasında %26'ya varan bir ısıl farka ve ısıl performansı zayıf duvarda yerel ısıl yük birikimine neden olmuştur. Ayrıca, köşe konumundaki emiş etkisinin ikincil akışlarla etkileşime girmesi genel basınç kaybını artırmıştır.

Özet (Çeviri)

Internal and external cooling of turbine blades are critical technologies for achieving continuous improvements in turbine inlet temperature, efficiency, and power output. While ribbed channels are employed for internal blade cooling, film cooling is utilized for external cooling. Positioning film cooling holes between the ribs within the channel alters the flow and thermal behavior inside the channel. The present study investigates the effect of this application on flow and heat transfer using CFD (Computational Flid Dynamics) analyses. The investigation focuses on a square-cross-section channel featuring ribs on two opposing surfaces. These ribs are oriented at a 90-degree angle with a blockage ratio (e/H) of 0.0625 and a pitch ratio (P/e) of 10. The Reynolds number for the channel flow is maintained at 21800. A uniform heat flux is applied to both the ribbed and smooth surfaces. Film cooling holes are positioned at 5 different locations between the ribs to observe the variation in heat transfer in the channel. It is defined that a fraction of 15% of the channel mass flow rate is discharged via the film cooling holes. The CFD analyses are performed by employing the v2-f turbulence model, which is a RANS model that closely matches the test data for rib turbulator applications. The analysis results were evaluated based on the average Stanton number and friction factor on the channel walls, along with the local temperature distributions. Although it was observed that the addition of holes generally enhanced heat transfer and reduced the friction factor, it was determined that the axial and lateral positions of the holes have critical effects on the channel performance. In the axial direction, the Front-Center and Mid-Center configurations yielded the highest average heat transfer, whereas localized hot spots induced by early fluid extraction were observed in the Rear-Center position. In the lateral direction, shifting the hole from the channel center toward the corner did not significantly alter the average thermal performance on the bottom wall; however, it caused a thermal asymmetry of up to 26% between the side walls and a localized thermal load accumulation on the wall with weaker thermal performance. Furthermore, the interaction of the suction effect at the corner position with secondary flows increased the overall pressure drop.

Benzer Tezler

  1. Cooling performance investigation of a two-pass rib-roughened channel

    U dönüşlü kanalda soğutma performansı araştırması

    İSA KAVAS

    Yüksek Lisans

    İngilizce

    İngilizce

    2015

    Orta Doğu Teknik Üniversitesi

    Havacılık ve Uzay Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  2. Numerical investigation of heat transfer in generic gas turbine blade with impingement cooling under high crossflow effect

    Yüksek çapraz akış etkisi altında çarpma jet soğutmalı jenerik bir gaz türbini kanadında ısı transferinin sayısal incelenmesi

    SEFA YILMAZ

    Yüksek Lisans

    İngilizce

    İngilizce

    2026

    İstanbul Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  3. Gaz türbini kanatlarında uygulanan fan şekilli film soğutma deliğinin giriş ve çıkışındaki yuvarlatmanın ve enjeksiyon açısının soğutma performansına etkileri

    Effects of inlet and exit rounding and injection angle on cooling performance of fan-shaped film-cooling hole applied to gas turbine blades

    MUSTAFA BOZOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2026

    Kırıkkale Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  4. Aerothermodynamics of turbine blade trailing edgecooling

    Türbin kanadı firar kenarı soğutmasının aerotermodinamiği

    TUĞBA TUNÇEL

    Yüksek Lisans

    İngilizce

    İngilizce

    2018

    Orta Doğu Teknik Üniversitesi

    Yükleniyor...

  5. Gaz türbin pasajını temsil eden 90° dönüşlü kanalda aerotermal inceleme

    Aerothermal investigation of a 90° turning duct simulating the gas turbine passage

    OZAN ŞENMAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2012

    İstanbul Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    Yükleniyor...