Nonlinear analysis methods for modelling of EEG and ECG signals
EEG ve EKG sinyallerinin modellenmesinde doğrusal olmayan analiz yöntemleri
- Tez No: 1031312
- Danışmanlar: DOÇ. DR. RAMASWAMY PALANIAPPAN
- Tez Türü: Doktora
- Konular: Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve Kontrol, Computer Engineering and Computer Science and Control
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2010
- Dil: İngilizce
- Üniversite: Unıversıty Of Essex
- Enstitü: Yurtdışı Enstitü
- Ana Bilim Dalı: Bilgisayar Bilimi Ana Bilim Dalı
- Bilim Dalı: Bilgisayar Bilimleri Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
Bu tezde, elektroensefalogram (EEG) ve elektrokardiyogram (EKG) sinyallerinin analizinde doğrusal olmayan dinamik özniteliklerin ve yüksek dereceli istatistiksel özniteliklerin kullanılabilirliği incelenmiştir. Doğrusal olmayan analiz yöntemleri dört farklı veri kümesi üzerinde denenmiştir: (i) sağlıklı bireylerden ve erken atım (prematüre kontraksiyon) görülen hastalardan kaydedilen EKG sinyalleri; (ii) sağlıklı bireylerden ve epilepsi hastalarından kaydedilen EEG sinyalleri; (iii) sağlıklı bireylerden sol işaret parmağının bükülmesi/açılması (fleksiyon/ekstansiyon) sırasında ve dinlenme hâlinde kaydedilen EEG sinyalleri; (iv) sağlıklı bireylerden motor imgeleme ve bilişsel görevler sırasında kaydedilen EEG sinyalleri. EEG/EKG segmentlerinin doğrusal olmayan analizi üç aşamada gerçekleştirilmiştir: (i) EEG/EKG segmentlerinin doğrusal olmama durumunun test edilmesi; (ii) doğrusal olmayan özniteliklerin ayırt etme gücünün doğrusal özniteliklerle karşılaştırılması; (iii) doğrusal ve doğrusal olmayan özniteliklerin birlikte kullanıldığı öznitelik kümelerinin ayırt etme gücünün sınanması. Özniteliklerin ayırt etme gücü, farklı fizyolojik veya patolojik durumlarda kaydedilen EEG/EKG segmentleri arasındaki sınıf ayrımı değerlendirilerek test edilmiştir. Farklı gömme parametresi çiftlerinin doğrusal olmayan dinamik özniteliklerin ayırt etme gücü üzerindeki etkisini incelemek amacıyla iki geleneksel parametre seçim yöntemi kullanılmıştır: Her iki yöntemde de gömme boyutu yanlış en yakın komşular (FNN) yöntemiyle belirlenirken, zaman gecikmesi birinci yöntemde otokorelasyon fonksiyonunun ilk sıfır geçişiyle (AC&FNN), ikinci yöntemde ise karşılıklı bilgi fonksiyonunun ilk yerel minimumuyla (MMI&FNN) belirlenmiştir. Bu yöntemlerin yanı sıra, genetik algoritma ve en küçük doğrusal olmayan tahmin hatasını kullanan, bu tezde önerilen bir yöntem (GA with NLPE) kullanılmıştır. EEG/EKG segmentlerinin doğrusal olmama durumu, deterministik-stokastik karşılaştırma (DVS) grafikleri ve vekil veri analizi yöntemi kullanılarak incelenmiştir. Geleneksel yöntemlerle seçilen gömme parametreleri kullanılarak oluşturulan EKG DVS grafikleri ile epilepsi hastalarından nöbet sırasında kaydedilen EEG segmentlerinin DVS grafikleri (tüm parametre seçim yöntemlerinde), deterministiklik olmayan ve doğrusal olmayan yapılara işaret etmiştir. GA with NLPE yöntemiyle seçilen gömme parametreleri kullanılarak oluşturulan EKG DVS grafikleri ve diğer tüm EEG veri kümelerinin DVS grafikleri (denenen her parametre seçim yönteminde) doğrusal ve stokastik bir yapıya işaret etmekle birlikte, zayıf doğrusal olmayan yapıların da bulunabileceğini göstermiştir. Doğrusal olmama belirtilerini incelemek amacıyla vekil veri yöntemi, yedi doğrusal olmayan test istatistiğiyle birlikte kullanılmıştır: üçüncü dereceden otokovaryans (C3), zaman tersinmesinden kaynaklanan asimetri (REV), korelasyon boyutu (CD), en büyük Lyapunov üsteli (LLE), doğrusal olmayan tahmin hatası (NLPE), yaklaşık entropi (APEN) ve Hurst üsteli (HURST). Bulgular, incelenen tüm veri kümelerinde farklı düzeylerde doğrusal olmayan yapıların bulunduğunu ve doğrusal olmama düzeyinin seçilen test istatistiğine ve gömme parametrelerine bağlı olduğunu göstermiştir. Genel olarak, epileptik EEG veri kümesi dışındaki tüm veri kümelerinde en yüksek doğrusal olmama düzeyi APEN özniteliğiyle saptanmıştır. Epileptik EEG veri kümesinde ise en yüksek doğrusal olmama belirtileri DVV özniteliğiyle, ardından APEN özniteliğiyle elde edilmiştir. Ayrıca, sağlıklı bireylerden ve erken atım görülen hastalardan kaydedilen EKG veri kümesinde ve epilepsi hastaları ile kontrol grubundan kaydedilen EEG veri kümesinde, patolojik durumlarda sağlıklı kontrollere göre daha belirgin doğrusal olmama belirtileri gözlenmiştir. Gömme parametresi seçim yöntemleri karşılaştırıldığında, GA with NLPE yöntemine dayanan test istatistikleri, zihinsel görev EEG veri kümesi dışındaki tüm veri kümelerinde en yüksek doğrusal olmama düzeylerini göstermiştir. Zihinsel görev EEG veri kümesinde ise parametre seçim yöntemlerinden herhangi birinin diğerlerine üstünlüğü saptanmamıştır. Yedi doğrusal olmayan özniteliğin, yani yüksek dereceli otokovaryans (cX), REV, LLE, CD, APEN, NLPE ve HURST özniteliklerinin ayırt etme gücü, doğrusal otoregresif model katsayıları (ARC) ve otoregresif yansıma katsayıları (ARK) ile karşılaştırılarak test edilmiştir. Ayrıca, zihinsel görev EEG veri kümesinden doğrusal bant gücü (BP) ve ortak uzamsal örüntü (CSP) öznitelikleri de çıkarılarak ayırt etme güçleri değerlendirilmiştir. En yüksek sınıf ayrılabilirliği; EKG veri kümesinde APEN ve LLE, epileptik EEG veri kümesinde doğrusal ARC, gerçek hareket veri kümesinde APEN, NLPE ve ARC, zihinsel görev EEG veri kümesinde ise CSP öznitelikleriyle elde edilmiştir. Gömme parametresi seçim yöntemleri karşılaştırıldığında, geleneksel yöntemlerle belirlenen parametreler kullanılarak hesaplanan doğrusal olmayan öznitelikler, tüm veri kümelerinde en yüksek sınıf ayrılabilirliğini sağlamıştır. Doğrusal ve doğrusal olmayan öznitelik kümelerinin birlikte kullanılması, her veri kümesinde tek başına en iyi sonucu veren özniteliğe kıyasla sınıf ayrılabilirliğinde anlamlı bir iyileşme sağlamıştır. Gömme parametresi seçim yöntemleri arasında, EKG veri kümesi dışında, sınıf ayrılabilirliği açısından anlamlı bir fark gözlenmemiştir. EKG veri kümesinde ise en yüksek sınıf ayrılabilirliği, GA with NLPE yöntemiyle hesaplanan doğrusal olmayan özniteliklerin kullanılmasıyla elde edilmiştir.
Özet (Çeviri)
In this thesis, the applicability of nonlinear dynamic and higher order statistics features were investigated for analysis of electroencephalogram (EEG) and electro- cardiogram (ECG) signals. The nonlinear analysis methods have been tested on four distinct data sets composed of: (i) ECG signals recorded from healthy subjects and patients with premature contraction beats, (ii) EEG signals recorded from healthy subjects and epilepsy patients, (iii) EEG signals recorded from healthy subjects during flexion/extension of left index finger and resting state, (iv) EEG signals recorded from healthy subjects whilst they were performing motor imagery and cognitive tasks. The nonlinear analysis of EEG/ECG segments has been approached in three steps: (i) checking the validity of nonlinear dynamic measures by testing the nonlinear- ity of EEG/ECG segments, (ii) testing the characterisation ability of nonlinear features in comparison to linear features, (iii) testing the characterisation abil- ity of combined linear and nonlinear feature sets. The characterisation ability of features was tested by assessing their class discrimination between EEG/ECG segments recorded during different physiological/pathological states. The estimation of nonlinear dynamic features involves selection of embedding di- mension and time lag parameters. For testing the influence of different embedding parameter pairs on the characterisation ability of nonlinear dynamic features two conventional methods of parameter selection using false nearest neighbours, the first zero crossing of autocorrelation function (AC&FNN) and first local minimum of mutual information function (MMI&FNN), were utlised along with a proposed method using a genetic algorithm and minimum nonlinear prediction error (GA with NLPE). The nonlinearity of EEG/ECG segments have been investigated using determin- istic versus stochastic (DVS) plots and the surrogate data analysis method. DVS plots of ECG data generated with embedding parameters from conventional meth- ods and DVS plots of EEG segments recorded from epilepsy patients during seizure intervals (for all parameter selection methods) showed indications of nonlinear structures with no determinism. DVS plots of ECG data generated based on the GA with NLPE method and all remaining EEG data sets (based on each parameter selection method tested) showed indications of linear stochastic nature, possibly with weak nonlinear structures. The surrogate data method has been used along with seven nonlinear test statistics namely third order autocovariance (C3), asymmetry due to time reversal (REV), correlation dimension (CD), largest Lyapunov exponent (LLE), nonlinear predic- tion error (NLPE), approximate entropy (APEN) and Hurst exponent (HURST) for investigating the indications of nonlinearity. Findings demonstrated that vary- ing degrees of nonlinearity exist in all the data sets tested, the rate of nonlinearity was dependent on the selected test statistics and embedding parameters. Overall, the highest degree of nonlinearity was indicated by APEN feature for all data sets except for epileptic EEG data set where the highest indications of nonlinearity were obtained with DVV feature followed by APEN feature. Furthermore, with ECG data set recorded from healthy subjects and patients with premature contraction beats as well as with EEG data set from epilepsy patients and control subjects, higher indications of nonlinearity was observed in pathological cases compared to healthy controls. Across embedding parameter selection methods, test statistics based on GA with NLPE method has indicated the highest degrees of nonlinearity for all data sets except mental task EEG data set where none of the parameter selection methods could be reported as superior to others. The characterisation ability of seven nonlinear features namely higher order au- tocovariance (cX), REV, LLE, CD, APEN, NLPE and HURST were tested in comparison to linear autoregressive model coefficients (ARC) and autoregressive reflection coefficients (ARK). Additionally, linear band power (BP) and common spatial pattern (CSP) features were also utilised for characterisation of mental task EEG data set. Highest class separabilities were obtained from; APEN and LLE features with ECG data set, linear ARC features with epileptic EEG data set, APEN, NLPE and ARC features with real movement data set and CSP features with mental task EEG data set. Across embedding parameter selection methods, nonlinear features estimated with conventional methods of parameter selection led to highest class discrimination for all data sets. The use of combined linear and nonlinear feature sets has shown a significant im- provement in class separabilities (in comparison to best individual feature) for ev- ery data set. Across embedding parameter selection methods, no significant differ- ences were observed in the class separabilities except for ECG data set, where the highest class separability was obtained with nonlinear features estimated through GA with NLPE method.
Benzer Tezler
- Dokuma kumaşlarda örgü tipinin ham kumaşın boyutları ve geometrik özellikleri üzerindeki etkilerinin araştırılması
Başlık çevirisi yok
EMEL ÖNDER
- Çorum toprak sanayii malzeme sahası olarak Sazköy killerinin etüdü
The Investigation of the Sazköy clays as meterial deposit for Çorum brick and the industry
METİN ARSLAN
- Bitlis-Zağros bindirme ve kıvrımlı kuşağının sismotektonik özellikleri
Başlık çevirisi yok
HALUK EYİDOĞAN
- Merkezsel ve dışmerkezsel çapraz elemanlı çerçeve yapıların statik ve deprem yüküne göre optimum tasarımı
Optimum desing of concentrically and eccentrically braced frames under static and earthquake loading
F.GÜLTEN GÜLAY
- İç ve dış yöneltme elemanlarının bilinmesi durumunda uzaysal kestirme problemlerinin çözümü ve yersel fotogrametride uygulama olanaklarının araştırılması
The Investigation of the solution of spatial intersection problems and the application possibilities on terrestrial photogrammetry in the case of interior and exterior orientation parameters are known
HÜSEYİN GAZİ BAŞ