Süleyman Demirel Üniversitesi Morfoloji Binası'nda ısıtma havalandırma sisteminin geliştirilmesi ve ekonomikliğinin araştırılması

Development of air conditioning system and economical analysis in Morphology Building of Süleyman Demirel University

  1. Tez No: 135789
  2. Yazar: GÖKHAN ERYİĞİT
  3. Danışmanlar: PROF. DR. MUSTAFA BAYHAN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Makine Mühendisliği, Mechanical Engineering
  6. Anahtar Kelimeler: Isıtma, havalandırma, otomatik kontrol, klima, kontrol paneli, Enerji tasarrufu, Havalandırma sistemleri, Isıtma sistemleri, Otomatik denetim, Heating, Air Conditioning, Automatic Control, Air Conditioner, Control Panel, Energy saving, Ventilating systems, Heating systems, Climate
  7. Yıl: 2003
  8. Dil: Türkçe
  9. Üniversite: Süleyman Demirel Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

ÖZET Bu çalışmada, S.D.Ü. Morfoloji binasında ısıtma ve havalandırma sistemlerinin geliştirilmesi ve ilave otomatik kontrol cihazları kullanılarak konvansiyonel sistemlere göre sağlanan enerji tasarrufunun hesaplanması amaçlanmıştır. Morfoloji binasında ısıtma ve havalandırma tesisatında otomatik kontrol sistemleri uygulanacaktır. Isıtma tesisatında eşanjör dairesinde bulunan dönüş kolektörü üzerinde bir üç yollu vana bağlantısı yapılarak sistemin gidiş ve dönüş suyu üzerinden sıcaklık daldırma tipi duyar elemanı vasıtasıyla sıcaklık kontrol panelinden alınan veriler yardımıyla enerji tasarrufunun ekonomikliğinin etkisi belirlenmiştir. Bu araştırmadaki şartlar için, otomatik kontrol cihazlarıyla desteklenen sistemlerde %25-30 arasında bir tasarruf sağlandığı ve ilk yatırım maliyetlerinin bir yıl içinde amorti ettiği sonucuna varılmıştır.

Özet (Çeviri)

VI ABSTRACT In this study, devolopment of systems of heating and air conditioning in morphology building of S.D.Universty and calculating of energy economy which is obtained according to the conventional systems using extra control equipments. In morghology buildingautomatic control systems are applied in the heating and ventilation installation, in the heating installation, the affect of the economy of energy is defined by the help of datum which is taken from the heat control panel by means of the heat plunging type of sensitive component on the going and turing water of system by doing the connection of a three means valve on the turing collector which is found in the cauldron department. The result of the getting an economy of the between 20-30 % in the systems which are supported with the automatic control equipments and amortizing of first investment cost in a year are reached for the conditions in this study.

Benzer Tezler

  1. Devlet Denetleme Kurulu

    Başlık çevirisi yok

    RIZA YURDDAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Kamu YönetimiGazi Üniversitesi

    Kamu Yönetimi Ana Bilim Dalı

    DOÇ. DR. SÜLEYMAN ARSLAN

  2. T.C. Anayasalarında basın hükümlerinin karşılaştırılması

    Başlık çevirisi yok

    REŞAT YAZICI

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    GazetecilikGazi Üniversitesi

    DOÇ. DR. SÜLEYMAN ARSLAN

  3. Basında cevap ve düzeltme hakkı

    Başlık çevirisi yok

    AYŞEN MANSOURİ BONAB

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    GazetecilikGazi Üniversitesi

    DOÇ. DR. SÜLEYMAN ARSLAN

  4. Kamu personelinin değerlendirilmesi

    Başlık çevirisi yok

    SEMİHA YAZICI

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Kamu YönetimiGazi Üniversitesi

    Kamu Yönetimi Ana Bilim Dalı

    DOÇ. DR. SÜLEYMAN ARSLAN

  5. Devlet güvenlik mahkemelerinin yapısı, görevleri ve yargılama usulleri

    Başlık çevirisi yok

    O.KADRİ KESKİN

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Kamu YönetimiGazi Üniversitesi

    DOÇ. DR. SÜLEYMAN ARSLAN