Boyun omurlarının (C3-C7) gövde hacimlerinin stereolojik yöntemlerle hesaplanması
Estimation of the volume of the cervical vertebral bodies (C3-C7) using stereological methods
- Tez No: 192476
- Danışmanlar: DOÇ.DR. BÜNYAMİN ŞAHİN, DOÇ.DR. İLTER KUŞ
- Tez Türü: Doktora
- Konular: Morfoloji, Morphology
- Anahtar Kelimeler: Vertebrae cervicales, corpus vertebrae, Cavalieriprensibi, hacim, bilgisayarlı tomografi, Cervical vertebra, vertebral body, volume, Cavalieri principle, computedtomography
- Yıl: 2006
- Dil: Türkçe
- Üniversite: Fırat Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Anatomi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Boyun omurlarının (C3-C7) gövde hacimlerininstereolojik yöntemlerle hesaplanmasıSerdar ÇOLAKOĞLUÖZETOmurları ilgilendiren enfeksiyonlarda, travmatik veya travmatik olmayannedenlerle ortaya çıkan kırıklarda ve deformitelerde corpus vertebrae'da kitlekaybı ve en-boy gibi özelliklerin değişmesi söz konusudur. Böyle durumlardacorpus vertebrae'nın hacminin bilinmesi tedavi veya cerrahi müdahale için kritiköneme sahiptir.Çalışmamız servikal omur gövdelerinin hacimlerinin, BT görüntüleriüzerinden Cavalieri prensibi ile hesaplanması ve gerekiyorsa yönteminkalibrasyonunu sağlamaya yönelikti. Bunun için 2 kadavraya ait C3-C7 arasıservikal vertebraları içeren boyun bölgeleri kullanıldı. Örnekler 3 anatomikdüzlemde, 3 mm ve 5 mm olmak üzere iki kalınlıkta baştan sona kadar taranarakBT görüntüleri standart filmlere basıldı. Cavalieri prensibi kullanılarak hacimlerihesaplandı. Vertebra gövdeleri ince diseksiyonla çevre dokulardan ayrıldı. Biraltın standart olarak kullanılmak üzere suya daldırma yöntemiyle vertebragövdelerinin gerçek hacimleri ölçüldü. Üç yönelim ve iki ayrı kalınlıktaki kesitlerüzerinden Cavalieri prensibi kullanılarak yapılan hesaplamalara göre vertebragövdelerinin hacim değerleri, 3,35 cm3 ile 6,67 cm3 arasında değişirken; gerçekhacimler ise, 3,15 cm3 ile 5,50 cm3 arasında değişiyordu. Hesaplanan hacimdeğerleri ile gerçek hacim değerleri arasında yüksek korelasyon görülmesinerağmen (r=0,937) bulunan değerlerin birbirinden istatistiksel olarak farklı olması(p<0,05) hesapla bulunan değerlerin gerçek değerden sistematik bir sapmagösterdiğini ortaya koymaktaydı. Bu sistematik sapmayı gidermek üzere her biryönelim ve kesit kalınlığı için düzeltme katsayıları belirlendi. Düzeltmekatsayıları kullanılarak sistematik sapması giderilen hacim değerleri omurlarıngerçek hacim değerlerinden istatistik bakımdan farklılık göstermiyordu (p>0,05).Sonuç olarak BT görüntüleri kullanarak servikal bölge omur gövdelerininhesaplanabildiği ve her bir yönelim ve kesit kalınlığı için önerilen düzeltmekatsayılarının kullanılması durumunda sistematik sapmanın giderilebileceğigösterildi.
Özet (Çeviri)
Estimation of the volume of the cervical vertebral bodies (C3-C7)using stereological methodsSerdar ÇOLAKOĞLUABSTRACTInfectious diseases related to the vertebra, traumatic or non-traumatic fractures anddeformities caused to loss of the mass of the vertebral body change the height and width ofvertebral body. In such cases knowing the volume of the vertebral body has a criticalimportance for treatment and surgical interventions.This study aimed to estimate the volume of cervical vertebral body on CT imagesusing the Cavalieri principle and also assessing whether a calibration is required to obtain areliable estimation. For this aim, we used two cadaveric specimens including C3-C7vertebras. Specimens were scanned using a CT (computer tomography) machine from end toend and the obtained images of sections at a thickness of 3 and 5 mm in three anatomicalplanes were printed on standard films. The volumes of the vertebral bodies were estimated onthese films using Cavalieri principle. After this estimation the vertebral bodies were dissectedfrom each other and surrounding tissue. The actual volumes of the isolated vertebras weremeasured using fluid displacement technique and the obtained values were used as ?the goldstandard? of this study. The estimated and measured volumes of the vertebral bodies using theCavalieri principle and the fluid displacement technique were ranging between 3.35-6.67 cm3and 3.15-5.50 cm3, respectively. Although there was observed a high correlation (r=0.937)between the estimated and measured values, but it was found a significant difference incomparison of these volume values (p<0.05). This deviation from the actual values may beattributed to technique used in CT images. We assessed coefficients for each section planesand thickness to overcome the systematical error. The corrected volume values of theCavalieri principle did not show significant difference from the actual volumes of thevertebral bodies (p>0.05).In conclusion, these results showed that the cervical vertebral body volumes can beestimated using CT images and the systematic error of the volume estimation can be correctedusing the proposed coefficients for each section plane and thickness.
Benzer Tezler
- İnsanda baş boyun modellenmesi
Modelling of human head neck
NURAY KORKMAZ
Yüksek Lisans
Türkçe
2010
Makine Mühendisliğiİstanbul ÜniversitesiMakine Mühendisliği Ana Bilim Dalı
PROF. DR. NURKAN YAĞIZ
- Artırılmış gerçeklik teknolojisinin spinal faset eklem enjeksiyonlarında kullanımının kadavra üzerinde araştırılması
Investigating the effectiveness of using augmented reality headset in spinal facet joint injections on human cadaver model
ALİ EKREM ADIYAMAN
Tıpta Uzmanlık
Türkçe
2022
Nöroşirürjiİstanbul ÜniversitesiBeyin ve Sinir Cerrahisi Ana Bilim Dalı
DOÇ. DR. PULAT AKIN SABANCI
- Spektroflorimetrik analiz yöntemlerinin toplam antioksidan kapasite tayinlerine uygulanması
Application of spectrofluorometric analysis methods to total antioxidant capacity assays
SEFA BAKİ
- Zein or gelatin nanofibers loaded with au nanospheres, SnO2 or black elderberry extract used as active and smart packaging layers for various fish fillets
Altın nanokürecikleri, SnO2 veya kara mürver ekstresi ile yüklenen zein ve jelatin nanoliflerinin farklı balık filetoları için aktif ve akıllı ambalaj katmanı olarak kullanılması
TURGAY ÇETİNKAYA
Doktora
İngilizce
2022
Gıda Mühendisliğiİstanbul Teknik ÜniversitesiGıda Mühendisliği Ana Bilim Dalı
PROF. DR. FİLİZ ALTAY
DOÇ. DR. ZAFER CEYLAN
- Futbolcuların boyun omurlarının radyolojik, manyetik rezonans ve biyomekanik incelenmesi
Radiographic, magnetic resonance and biomechanic analysis of cervical spine of soccer players
ALPASLAN KARTAL