Teknezyum 99m dimerkaptosüksinik asid spect görüntülerinde uygulanan filtrelenmiş geri projeksiyon ve iterativ rekonstrüksiyon yöntemlerinin görüntü kalitesi üzerine etkilerinin belirlenmesi
Determination of filtered back projection and iterative reconstruction algoritms effect on image quality in technetium-99m dimercaptosuccinic acid renal spect
- Tez No: 193895
- Danışmanlar: DOÇ.DR. GÜLAY DURMUŞ-ALTUN
- Tez Türü: Tıpta Uzmanlık
- Konular: Radyoloji ve Nükleer Tıp, Radiology and Nuclear Medicine
- Anahtar Kelimeler: yapılandırma, Tc-99m DMSA, kidney, scintigraphy, SPECT, reconstruction
- Yıl: 2006
- Dil: Türkçe
- Üniversite: Trakya Üniversitesi
- Enstitü: Tıp Fakültesi
- Ana Bilim Dalı: Nükleer Tıp Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
ÖZETDimerkaptosüksinik asid böbrek sintigrafisi, çocuk ve yetişkinlerde böbrekparankiminin değerlendirilmesinde yaygın olarak kabul edilen referans yöntemdir. Planarteknikte alınan iki boyutlu görüntülerle böbrek korteksi değerlendirilir. Son çalışmalarda,böbreklerdeki lokalize patolojilerin belirlenmesinde SPECT çalışmasının duyarlılığının dahayüksek olduğu belirtilmektedir. Bu çalışmada, 360° ve posteriyor 180° dimerkaptosüksinikasid SPECT görüntüleri elde edilerek, filtrelenmiş geri projeksiyon ve iterativ yenidenyapılandırma yöntemleriyle işlemlenmiştir. Her iki görüntüleme ve yeniden yapılandırmateknikleri birbiriyle karşılaştırılarak görüntü kalitesi ve lezyon saptanması üzerindekietkilerinin belirlenmesi amaçlanmıştır.Çalışma grubuna bir yıllık süreçte Tc-99m dimerkaptosüksinik asid ile planar veSPECT böbrek görüntülemesi yapılan 37 hasta (3 erkek, 34 kadın, ortalama yaş: 20±15 yıl)dahil edildi. Hastalar yaşlarına göre çocuk (grup A, n=23, ortalama yaş: 9±2 yıl) ve erişkin(grup B, n=14, ortalama yaş: 38±9 yıl) hasta olmak üzere iki alt gruba ayrıldı. Hastalar ayrıcaTc-99m dimerkaptosüksinik asid sintigrafisi sonucuna göre normal (n=19) ve patolojik (n=18)olmak üzere iki gruba ayrıldı ve normal grupta yer alanların görüntüleri, farklı işlemlemetekniklerinin görüntü kalitesinin karşılaştırılmasında kullanıldı.SPECT180İR tekniği hem görsel değerlendirmede hem de lezyon saptanmasındaplanar teknikle en uyumlu sonuçları vermiştir (κ=0.57, p=0.001, r=0.70, p=0.0001). Görüntükontrastı 180° SPECT görüntülerinde, 360° SPECT görüntülerinden daha yüksekbulunmuştur. SPECT360FBP en fazla yalancı pozitif sonuç veren yöntemdir. HemSPECT180İR hem de SPECT180FBP ile planar görüntülemeden daha fazla sayıda defektsaptanmıştır. SPECT180İR'nin defekt saptama gücü SPECT180FBP ile benzerdi, ancakgörüntü kalitesi göreceli olarak daha iyiydi.Tc-99m DMSA, böbrek, sintigrafi, SPECT, yeniden
Özet (Çeviri)
DETERMINATION OF FILTERED BACK PROJECTION ANDITERATIVE RECONSTRUCTION ALGORITMS EFFECT ON IMAGEQUALITY IN TECHNETIUM-99m DIMERCAPTOSUCCINIC ACIDRENAL SPECTSUMMARYDimercaptosuccinic acid renal scintigraphy is the most commonly accepted reliableimaging technique for evaluation of renal paranchima in both children and adults. Thetraditional planar technique provides adequate two dimensional imaging of the renal cortex.Recent reports suggested that compared to planar imaging, SPECT has higher sensitivity forthe detection of focal abnormalities in the kidneys. In this study, posterior 180° and 360°dimercaptosuccinic acid SPECT images were obtained. SPECT images were reconstructedwith filtred back-projection and iterative algoritms. The aim of this study was determine theeffect of filtred back projection and iterative reconstruction algoritms on image quality andlesion detection in both acquisitions.Thirty seven consequtive patients (3 men, 34 women, mean age: 20±15 years)examined with Tc-99m dimercaptosuccinic acid imaging in both planar and SPECTacquisitions during the one year were included in this study. Study group were divided intotwo subgroup according to the age of patients: Grup A as child patients (younger than 18years-old, n=23, mean age: 9±2 years) and Grup B as adult patients (older or equal 18 years-old, n=14, mean ages: 38±9 years). Patients were divided into other two subgrups based onthe results of planar dimercaptosuccinic acid images, normal (n=19) and pathologic(n=18).The images of the normal planar dimercaptosuccinic acid group were used for theevaluation of the image qualities of our reconstruction methods. SPECT180IR tecniqueshowed the most similarity with planar imaging on both visual evaluation and lesion areadetection (κ=0.57, p=0.001, r=0.70, p=0.0001 respectively). The posterior 180° DMSASPECT has higher lesion contrast in comparison with 360° acquisition. SPECT360FBP failedto determine many of the cortical defects, and its had the most frequent false positive results.Both SPECT180İR and SPECT180FBP significantly detected more of the renal defects thanplanar imaging. The sensibilty of posterior SPECT180İR in the detection of renal defects wasequal to SPECT180FBP, but its visual image quality was better.
Benzer Tezler
- Meme kanserinde Tc-99m V-DMSA (Pentavalan-Dimerkaptosüksinik Asid) sintigrafisi ile F-18 FDG PET/BT çalışmalarının karşılaştırılması ve sintigrafik çekimler esnasında meme yastığı ile pozisyonlanmış ve pozisyonlanmamışgörüntülerin karşılaştırılmalı değerlendirilmesi
Comparison of Tc-99m V-DMSA scintigraphy and F-18 FDG PET/CT in breast cancer and evaluation of scintigraphic images obtained with and without breast positioining
SEZEN ELHAN VARGÖL
Tıpta Uzmanlık
Türkçe
2014
Radyoloji ve Nükleer TıpHacettepe ÜniversitesiDahili Tıp Bilimleri Bölümü
PROF. DR. ESER LAY ERGÜN
- Teknesyum-99m DMSA sintigrafisinde rölatif renal fonksiyonu %10 ve altında olan obstrükte böbreklerde iki aşamalı tedavi protokolünün uzun dönem sonuçlarının araştırılması
Evaluation of long-term results of two-phase treatment protocol in obstructed kidneys with relative renal function with 10% and lower in techesium-99m DMSA scintigraphy
ABDULLAH GÖLBAŞI
Tıpta Uzmanlık
Türkçe
2021
ÜrolojiErciyes ÜniversitesiÜroloji Ana Bilim Dalı
PROF. DR. ABDULLAH DEMİRTAŞ
- Teknezyum-99m dimerkaptosüksinik asit SPECT ile yapılan statik böbrek sintigrafisinde gözlemci içi ve gözlemciler arası uyumun belirlenmesi
The evaluation of inter- and intraobserver variability of 99mTc- dimercaptosucsinic acid SPECT renal scintigraphy
ÜNAL CAN
Tıpta Uzmanlık
Türkçe
2008
Radyoloji ve Nükleer TıpTrakya ÜniversitesiNükleer Tıp Ana Bilim Dalı
DOÇ. DR. GÜLAY DURMUŞ-ALTUN
- Meme kitlelerinin benign ve malign ayırıcı tanısında teknesyum-99m pentavalent dimerkaptosüksinik asitle sintimammografinin yeri ve önemi
The role and significance of pentavalent of technetium di mercaptosuccinic acid in the differentral diagnosis of mammary masses
GÜN KARA
Tıpta Uzmanlık
Türkçe
2003
Radyoloji ve Nükleer TıpAnkara ÜniversitesiNükleer Tıp Ana Bilim Dalı
PROF. DR. ASIM AKİN
- Perkütan nefrolitotomi ameliyatında giriş sayısının renal fonksiyonlar üzerine etkisinin teknesyum-99m-dimerkaptosüksinik asit sintigrafisi ile değerlendirilmesi
Assessment of the effects of access count in percutaneous nephrolithotomy on renal functions by 99m-technetium-dimercaptosuccinic acid scintigraphy
MEHMET CANİKLİOĞLU
Tıpta Uzmanlık
Türkçe
2010
ÜrolojiErciyes ÜniversitesiÜroloji Ana Bilim Dalı
YRD. DOÇ. DR. ABDULLAH DEMİRTAŞ