Mekanik yüklemenin farklı kök ucu dolgu materyallerinin apikal sızıntılarına ve boşluk hacimlerine etkisi ve oluşan streslerin sonlu eleman stres analiz (FEA) yöntemiyle değerlendirilmesi
Effect of mechanical loading on apical leakage and gap volumes of different root-end filling materials and evaluation of stresses via finite element analysis (FEA)
- Tez No: 329280
- Danışmanlar: PROF. SEMA BELLİ
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2012
- Dil: Türkçe
- Üniversite: Selçuk Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Diş Hekimliği Bölümü
- Bilim Dalı: Endodonti Ana Bilim Dalı
- Sayfa Sayısı: 123
Özet
Bu çalışmanın amacı yedi farklı kök ucu dolgu materyalinin apikal mikrosızıntısı ve iç yapısında oluşan boşlukların hacmi üzerine 1 yıla tekabül eden mekanik yüklemenin etkisinin değerlendirilmesi ve sonlu eleman stres analiz (FEA) yöntemi ile oluşan streslerin miktarı ve dağılımının incelenmesidir.Bu çalışmada periodontal nedenlerle çekilmiş 112 adet insan maksiler santral keser dişler kullanıldı. Tüm dişlere giriş kavitesi açılmasının ardından kök kanalları ProTaper F4 gütta-perka konlar ve AH Plus kanal patı kullanılarak dolduruldu. Tüm dişlerin apikal 3 mm'lik kısımları rezeke edildikten sonra elmas kaplı ultrasonik uç ile 3 mm derinliğinde kök ucu kaviteleri açıldı. Dişler yedi gruba (n=16) ayrıldı ve kök ucu kaviteleri ProRoot MTA, Super EBA, IRM, Vitrebond, Geristore, kompozit rezin ve TechBiosealer ile dolduruldu. Örneklerin mikrosızıntısı mekanik yükleme (100000, 50 N, 0,2 Hz) öncesinde ve sonrasında sıvı filtrasyon test metodu kullanılarak değerlendirildi. Elde edilen veriler Kruskal Wallis, Wilcoxon testi kullanılarak analiz edildi.Materyal içi boşlukların hacmininin yüzdesini ölçmek amacıyla her gruptan seçilen 7 örneğin mekanik yükleme öncesinde ve sonrasında mikro CT cihazı kullanılarak elde edilen kesit görüntüleri üç boyutlu modeller oluşturmak üzere MIMICS 10.01 yazılımına aktarıldı. Bu programla materyallerin üç boyutlu görüntüleri üzerinde içerdikleri boşluk hacmi yüzde değerleri ölçüldü ve kaydedildi. Elde edilen veriler Kruskal Wallis, Banferonni düzeltmeli Mann Whitney U ve Wilcoxon testleri kullanılarak değerlendirildi. Mikro CT ile elde edilen veriler SolidWorks (2009) üç boyutlu çizim programına aktarılarak stres analizi yapıldı.Bu çalışmada mekanik yükleme öncesinde ve sonrasında mikrosızıntı değerleri açısından gruplar arasında istatistiksel olarak anlamlı farklılık bulunmadı (p>0,05). Mekanik yükleme sonrasında TechBiosealer'in mikrosızıntısı anlamlı azalış, IRM'nin mikrosızıntısı anlamlı olarak artış gösterdi (P
Özet (Çeviri)
The aim of current study was to the effect of mechanic cyclic loading simulating one year of usage on apical leakage and volume of voids inside the root end filling material, and the evaluation of amount and distribution of stresses via finite element analysis (FEA).112 human central incisor teeth extracted due to periodontal disease were used at current study. Root canals were filled with ProTaper F4 gutta-percha cones and AH Plus paste following the preparation of access cavity. Root end cavities of 3 mm depth were prepared with diamond coated ultrasonic tips after the resection of 3 mm apical parts of all teeth. Teeth were divided in to seven groups (n=16) and root end cavities were filled with ProRoot MTA, Super EBA, IRM, Vitrebond, Geristore, Composite Resin, and TechBiosealer. Microleakage of specimens were evaluated by fluid filtration method both before and after mechanical loading (100000, 50 N, 0,2 Hz). Data acquired were evaluated by Kruskal Wallis, Wilcoxon statistical tests.In order to measure the percentage of void volumes, cross-section views of seven specimens acquired by microCT device both before and after mechanical loading were transferred in to MIMICS 10.01 software to develop three dimensional models. Percentage of void volume values were measured and recorded via this software. Data acquired were evaluated by Kruskal Wallis, Mann Whithey U test with Bonferonni correction, and Wilcoxon statistical tests. Data acquired by microCT were transferred in to SolidWorks (2009) software and stress analyses were performed.There were no statistically significant differences among groups as micro-leakage values neither before nor after mechanical loading (p>0,05). Micro-leakage of TechBioselaer exhibited significant decrease after mechanical loading, while micro-leakage of IRM was increasing (p
Benzer Tezler
- Kısmi yüklü dalgakılavuzları ile mikrodalga cihazı tasarımının ters saçılma ve optimizasyon problemi olarak incelenmesi
Analysis of partially filled waveguides for the synthesis of microwave devices as an inverse and optimization problem
AHMET AYDOĞAN
Doktora
Türkçe
2017
Elektrik ve Elektronik Mühendisliğiİstanbul Teknik ÜniversitesiElektronik ve Haberleşme Mühendisliği Ana Bilim Dalı
PROF. DR. FUNDA AKLEMAN YAPAR
- Beşinci metakarpal kırıklarının tedavisi için yeni bir yaklaşım geliştirilmesi
Development of a new approach for the treatment of fifth metacarpal fractures
LÜTFİYE CAYMAZ
Yüksek Lisans
Türkçe
2024
BiyomühendislikSakarya ÜniversitesiBiyomedikal Mühendisliği Ana Bilim Dalı
DR. ÖĞR. ÜYESİ OSMAN İYİBİLGİN
DOÇ. DR. LEVENT BAYAM
- İnek sütünden eksozom eldesi ve antimikrobiyal etkinliklerinin araştırılması
Investigation of exosomes from cow milk and antimicrobial effects of exosomes
BÜŞRA EROL
- Turbojet motoru kompresör çarkının yapısal analizi
Structural analysis of turbojet engine compressor wheel
TALHA ENSAR BAŞ
Yüksek Lisans
Türkçe
2021
Mühendislik Bilimleriİstanbul Teknik ÜniversitesiUçak ve Uzay Mühendisliği Ana Bilim Dalı
PROF. DR. ZAHİT MECİTOĞLU
- 1d to 3d mapping of wind turbine blade structural behavior using a coupling method
Eşleşme yöntemi kullanarak rüzgar türbin kanatlarının yapısal davranışlarının 1bde 3b ye haritalanmasi
SEYED FARHAD ABTAHI
Yüksek Lisans
İngilizce
2018
Gemi Mühendisliğiİstanbul Teknik ÜniversitesiDR. ÖĞR. ÜYESİ SERDAR AYTEKİN KÖROĞLU