Geri Dön

Kentsel atıksu arıtan arıtma tesisinin modellenmesi ve genel atıksu karakteristiğinin endüstriyel etkilerinin belirlenmesi

Modelling of urban wastewater treatment plant and determination of the effects of industrial discharges on urban wastewater characteristic

  1. Tez No: 432887
  2. Yazar: YETER TURSUN
  3. Danışmanlar: PROF. DR. BÜLENT KESKİNLER, DOÇ. DR. HAYRETTİN GÜÇLÜ İNSEL
  4. Tez Türü: Doktora
  5. Konular: Çevre Mühendisliği, Environmental Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2016
  8. Dil: Türkçe
  9. Üniversite: Gebze Teknik Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Çevre Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmada İSU Genel Müdürlüğü bünyesinde bulunan KAAT (Kentsel atıksu arıtma tesisi) atıksu karakterizasyonu ve modellemesi yapılmış, endüstriyel deşarjların genel atıksu karakteristiğine ve işletmeye etkileri incelenmiştir. Atıksu karakterizasyonu ve modellemesi için 2011 yılı kompozit numuneler kullanılmıştır. Biyolojik arıtılabilirlilik çalışmaları Eylül ayında alınan örnekle yürütülmüştür. 2011 yılı KAAT giriş KOİ değerleri 1930-3582 mg/L aralığında değişmekte, standart sapması 520 mg/L değerini almaktadır. Endüstrilerin AKDY'de (Atıksuların Kanalizasyona Deşarj Yönetmeliği) belirtilen deşarj limitlerine uymadığı belirlenmiştir. KAAT'ye en büyük etki maya,atıksularından kaynaklanmaktadır ve evsel atıksuların seyrelme etkisinin büyük olduğu görülmüştür. Biyolojik arıtılabilirlilik çalışmaları değerlendirildiğinde toplam atıksuyun %17.6 kolay ayrışabilir KOİ, % 6 sı çözünmüş inert KOİ, %28 'i çözünmüş yavaş ayrışabilir KOİ, %41 partiküler yavaş ayrışabilir KOİ, %7.4 partiküler inert KOİ olarak bulunmuştur. Aktif çamur ikili hidroliz şeklinde modellenmiş, simülasyonda Aquasim programı kullanılmıştır. KAAT nin deşarjının Kentsel Atıksu Arıtma Yönetmeliği'ne(KAAY) uymadığı belirlenmiştir. KAAY uymamasının nedeni olarak KAAT çıkışındaki inert KOİ ve yavaş hidroliz olabilen KOİ'nin olduğu tespit tespit edilmiştir. Endüstrilerin AKDY yönetmeliğe uymaları ve atıksu karakterinin evsel nitelikte olması halinde çamur üretiminde % 61 azalma, oksijen ihtiyacında % 61 azalma ve havalandırma enerji tüketiminde ise % 65 azalma olacağı tespit edilmiştir. Bu bölgede tüm endüstrilerin İSU denetim birimleri tarafından 24 saat kontrol edildiği, denetimler esnasında alınan numune analiz sonuçları ile KAAT sonuçlarının örtüşmediği ve sonuç olarak kaçak deşarjların olduğu sonucuna varılmıştır. Endüstrilerin denetimlerinin teknolojik olarak yapılmasının zorunlu hale geldiği, klasik yöntemlerle denetimlerin artık terk edilmesi gerekliliği öneri olarak sunulmuştur.

Özet (Çeviri)

In this study, the Urban Wastewater Treatment Plant (UWTP) under the General Directorate of Kocaeli Water, Sewerage Administration (ISU) was made of the wastewater characterization and modelling. The industrial discharges effects on the general wastewater features and their impact to general operation were examined The activated sludge model parameters and the charatecteristic of wastewater were determined using composite samples in 2011. İn 2011, UWTP inlet COD values ranging from 1930 to 3582 mg/L , standart deviation of COD was 520 mg/L. It was concluded that the industries did not observe discharge limits as specified in Regulations for wastewater discharge into sewage (AKDY). The greatest impact of UWTP is due to yeast wastewater and it was seen that that of great influence dilution of domestic wastewater.İn thebiological treatability studies ; % 17,6 readly biodegradable COD, % 6 soluble inert COD, % 28 slowly biodegradable soluble COD , % 41 slowly biodegradable partıculate COD and % 7.4 particulate inert COD of the total COD were evaluated. The activated sludge was modeled as binary hydrolysis and the simulation of UWTP were performed with Aquasim. The discharge of UWTP was determined not compatible of the Urban Wastewater Directive. As cause of non compliance the Urban Wastewater Treatment Directive ,it was determined inert and slowly biodegradable soluble COD of the discharge UWTP. It was also noted that if the regulations were observed, the sludge production, oxygen demand and energy costs could be reduced by % 61, % 61, % 65 respectively. At the end of this study, it was suggested that the industrial inspections should be conducted by more technological methods and more conventional methods should be abandoned.

Benzer Tezler

  1. Atıksu arıtma tesislerinin model desteği ile iyileştirilmesi ve optimizasyonu

    Model supported rehabilitation and optimization of wastewater treatment plants

    GAMZE KIRIM

    Yüksek Lisans

    Türkçe

    Türkçe

    2015

    Çevre Mühendisliğiİstanbul Teknik Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    DOÇ. DR. ÖZLEM KARAHAN ÖZGÜN

  2. High-rate activated sludge process for energy efficient wastewater treatment

    Enerji verimli atıksu arıtımı için yüksek yüklemeli aktif çamur prosesi

    HAZAL GÜLHAN

    Doktora

    İngilizce

    İngilizce

    2023

    Çevre Mühendisliğiİstanbul Teknik Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    PROF. DR. İZZET ÖZTÜRK

  3. Critical evaluation for nitrogen removal performance of a stereotype activated sludge system under dynamic process conditions

    Dinamik proses koşulları altında stereotip aktif çamur sisteminin azot giderme performansı için kritik değerlendirme

    MİNEL BODUR

    Yüksek Lisans

    İngilizce

    İngilizce

    2021

    Çevre Mühendisliğiİstanbul Teknik Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    PROF. DR. HAYRETTİN GÜÇLÜ İNSEL

  4. Kentsel atıksulardan uzun süreli ozonlama ile KOİ, diklofenak giderimi ve kısmi nitrifikasyon

    Removal of COD and diclofenac, and partial nitrification in municipal wastewater via extended ozonation

    BURKAY KÖKNAR

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    Çevre Mühendisliğiİstanbul Teknik Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    PROF. İZZET ÖZTÜRK

  5. Kentsel atıksu arıtma tesisinin online izlenmesi ile enerji etüt ve optimizasyonu

    Energy study and optimization by online monitoroing of urban wastewater treatment plant

    İSMAİL GÜLSOY

    Doktora

    Türkçe

    Türkçe

    2017

    EnerjiKocaeli Üniversitesi

    Enerji Sistemleri Mühendisliği Ana Bilim Dalı

    PROF. DR. İBRAHİM KILIÇASLAN