Geri Dön

Vertebra metastazlarında farklı planlama teknikleri ile medulla spinalisin maksimum doz değerinin karşılaştırılması

Comparison of maximum dose value of medulla spinal with different planning techniques in vertebra metastases

  1. Tez No: 519495
  2. Yazar: FATİH MEHMET DÖNER
  3. Danışmanlar: PROF. DR. NİLGÜN ÖZBEK OKUMUŞ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Nükleer Mühendislik, Onkoloji, Nuclear Engineering, Oncology
  6. Anahtar Kelimeler: Vertebra, Medulla spinalis, 3D-CRT, IMRT, VMAT, Vertebra, Medulla spinalis, 3D-CRT, IMRT, VMAT
  7. Yıl: 2018
  8. Dil: Türkçe
  9. Üniversite: Ondokuz Mayıs Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Radyolojik Bilimler Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 67

Özet

Amaç: Çalışmamızda, vertebra metastazlarında planlama tekniklerinin medulla spinalisin maksimum doz değerine (D-maks), homojenite (HI) ve konformalite indeksine (CI) etkisi araştırıldı. Materyal ve Metot: Bu çalışmada Ondokuz Mayıs Üniversitesi Radyasyon Onkolojisi Anabilim Dalı'nda vertebra metastazı nedeni ile tedavi edilen 20 hastanın 3 mm kesitlerle çekilen bilgisayarlı tomografi görüntüleri kullanıldı. Metastatik vertebranın bir üst ve altındaki vertebrayı içerecek şekilde klinik hedef hacim (CTV) oluşturuldu. CTV'ye her yönden 5 mm marjin verilerek planlanan hedef hacim (PTV) belirlendi. Her bir hasta için 3-boyutlu konformal radyoterapi (3D-CRT), alan-içinde-alan yoğunluk ayarlı radyoterapi (for-IMRT), IMRT ve hacimsel yoğunluk ayarlı ark tedavisi (VMAT) planlamaları yapıldı. PTV'ye doz, fraksiyon başına 3 Gray (Gy)'den toplam 30 Gy olarak tanımlandı. Elde edilen tüm verilerin istatistiksel analizinde SPSS 24.0 programı kullanıldı. Bulgular: Ortanca D-maks değerleri VMAT ve IMRT'de 3D-CRT ile for-IMRT'den istatistiksel olarak anlamlı düzeyde (p=0.000) daha düşüktü. Ortanca HI değerlerinin, VMAT ve IMRT tekniklerinde karşılaştırılmasında istatistiksel anlamlı fark saptanmazken (p>0.05), her iki tekniğin hem for-IMRT hem de 3D-CRT'den istatistiksel olarak anlamlı düzeyde (p=0.000) daha düşük HI değerlerine sahip olduğu belirlendi. Ortalama CI değerlerine göre tüm planlama teknikleri arasında istatistiksel anlamlı fark (p≤0.001) saptandı. En konformal planlama, VMAT tekniği ile elde edildi. Sonuç: IMRT veya VMAT tekniği ile vertebra metastazlarının tedavisinde daha iyi CI ve HI değerleri ile en düşük doz maksimum değeri elde edilerek tedavi planlaması yapılmaktadır.

Özet (Çeviri)

Aim: In our study, the effect of planning techniques on vertebral metastases on maximal dose of medulla spinalis (D-max), homogeneity (HI) and conformity index (CI) was investigated. Material and Method: In this study, 20 patients treated with the reason of vertebrae metastases in Ondokuz Mayıs University Radiation Oncology Department, computerized tomography images taken with 3 mm cross section were used. The clinical target volume (CTV) was defined as the metastatic vertebrae with an upper and a lower vertebrae. The planned target volume (PTV) was created by giving a margin of 5 mm on each side of the CTV. Three-dimensional conformal radiotherapy (3D-CRT), field-in-field intensity modulated radiotherapy (for-IMRT), IMRT and volumetric modulated arc therapy (VMAT) planning were performed for each patient. The PTV dose was defined as a total of 30 Gy per 3 Gray (Gy) per fraction. Statistical analysis of all data was performed with the SPSS 24.0 program. Results: Median D-max values were statistically significantly lower (p = 0.000) than 3D-CRT and for-IMRT in VMAT and IMRT. There was no statistically significant difference between the median HI values in VMAT and IMRT techniques (p> 0.05) and both techniques had lower HI values statistically significant (p = 0.000) than both for-IMRT and 3D-CRT. A statistically significant difference (p≤0.001) was found between all planning techniques according to the mean CI values. The most conformal planning was achieved with the VMAT technique. Conclusion: In planning for vertebra metastases, planning with IMRT or VMAT technique is recommended to provide better CI and HI values and the lowest dose maximum.

Benzer Tezler

  1. Ağrılı kemik metastazlarında palyatif radyoterapi yanıtını etkileyen faktörler

    Factors affecting the response to palliative radiotherapy in patients with painful bone metastasis

    SERAP KORKMAZ AYDOĞDU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2008

    OnkolojiOndokuz Mayıs Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    DOÇ. DR. NİLGÜN ÖZBEK OKUMUŞ

  2. Cyberknife robotik radyocerrahi cihazı ile yapılan kanser tedavilerinde farklı tümör türleri için hacim – doz miktarı ilişkisinin incelenmesi

    An investigation of relationship between volume and dose value for the different tumor types on treated by cyberknife robotic radiosurgery device

    EMİR BÜYÜKOK

    Yüksek Lisans

    Türkçe

    Türkçe

    2014

    Fizik ve Fizik MühendisliğiEge Üniversitesi

    Nükleer Bilimler Ana Bilim Dalı

    YRD. DOÇ. DR. MEHMET BAYBURT

  3. Vertebra metastazlarında mr-linak ve cyberknife tedavi planlarının karşılaştırılması

    Comparison of MR-linac and cyberknife plans for vertebra metastases

    HANDE KAYACIK

    Yüksek Lisans

    Türkçe

    Türkçe

    2022

    Radyasyon OnkolojisiAcıbadem Mehmet Ali Aydınlar Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    PROF. DR. MEHMET UFUK ABACIOĞLU

  4. Kemik metastazlarında palyatif radyoterapi: Radyasyon doz ve fraksiyonunun randomize edildiği bir çalışma

    Başlık çevirisi yok

    ZEYNEP ÖZSARAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1995

    OnkolojiEge Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    Y.DOÇ.DR. MUSTAFA ESASSOLAK