Geri Dön

Design of vibration isolation systems that incorporate axial to rotary motion conversion mechanisms

Eksenel hareketi dönme hareketine çeviren atalet artırım mekanizması tasarımı

  1. Tez No: 523105
  2. Yazar: ADİL HAN ORTA
  3. Danışmanlar: DOÇ. DR. ÇETİN YILMAZ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Makine Mühendisliği, Mechanical Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2018
  8. Dil: İngilizce
  9. Üniversite: Boğaziçi Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 96

Özet

Bu tezde, titreşim yalıtım bant aralıkları oluşturmak amacıyla esnek bağlantılı eksenel hareketi dönme hareketine çeviren mekanizmalar incelenmiştir. Düşük frekanslarda fonon bant aralıkları elde edebilmek için LADD mekanizması incelenmiş ve efektif ataleti arttırılmaya çalışılmıştır. Ayrıca, yalıtım bant aralıklarının genişletilmesi amacıyla helisel teller araştırılmış, analitik ve sonlu eleman modelleri yaratılmıştır. Kurulan modeller deneylerle doğrulanmıştır. Sonra yapıya öngerilme uygulanarak ve helisel tellerin kesit alanları eniyilenerek yapının fonon bant aralığı düşük frekanslarda maksimize edilmiştir. Oldukça geniş bir bant aralığı w1/w2=0.215 frekans oranı ve idealize edilmiş basit mesnet sınır koşullarıyla elde edilmiştir. Ancak bu tip bir sınır koşulu esnek bağlantılı teller aracılığıyla realize edilmeye çalışıldığında frekans oranı (w1/w2) 0.5'e çıkmış ve bant aralığı daralmıştır. Bu sebeple eksenel hareketi dönme hareketine çeviren özgün bir yapı önerilmiştir. Önerilen birim hücrede yalıtım bant aralığının iki farklı mod şekline bağlı olduğu görülmüştür. Yalıtım bandının alt ve üst frekans limitleri sırasıyla eksenel-dönme ve eğilme moduna bağlıdır. Yalıtım bant aralığının maksimize edilmesi amacıyla çapraz ve spiral esnek bağlantı mekanizmaları yüksek eğilme ve düşük eksenel rijitliğe sahip olduğu için kullanılmıştır. Ek olarak, yüksek helis açılı teller eksenel hareketten dönme hareketi sağlamak için kullanılmıştır. Böylece sistemin efektif ataleti arttırılmıştır. Parametrik çalışmalar sayesinde düşük frekaslarda geniş bant aralıkları elde edilmiştir. Birim hücre ve periyodik yapıların prototipleri 3 boyutlu yazıcı ve lazer kesim metotlarıyla üretilmiştir. Son olarak, analitik, sonlu eleman ve deney sonuçları doğrulama amacıyla karşılaştırılmıştır. Sonuçta düşük frekansta çok geniş fonon bant aralığı (w1/w2=0.221) elde edilmiştir.

Özet (Çeviri)

In this thesis, compliant axial to rotary motion conversion mechanisms are examined to generate isolation band gaps. To achieve low frequency phononic band gaps, LADD mechanism is examined, and its the effective inertia is aimed to be amplified. Moreover, to increase the isolation band gap of this structure, helical wire theory is investigated, and both analytical and finite element models of the mechanism are created and validated with experiments. Then, by applying prestress and optimizing the cross section area of the helical wires, the phononic band gap is maximized at low frequencies. A quite wide band gap with w1/w2=0.215 is obtained with the use of idealized roller boundary conditions. However, this type of boundary condition is compliantly realized via wires, the frequency ratio (w1/w2) increased to 0.5 and the band gap became narrower. Therefore, a novel axial to rotary motion conversion mechanism is proposed. In the proposed unit cell, a stop band is governed by two different types of modes. The lower and the upper natural frequencies of stop band is limited by the coupled axial-torsional and bending modes, respectively. For stop band maximization, cross and spiral flexures are used due to their high bending stiffness and low axial stiffness. Besides, helical wires with large pitch angle are utilized to create large rotational motion from axial translations. Thus, the effective inertia of the mechanism is amplified. By using analytical and finite element models, band structure and the dynamic response attributes of the structure are examined, and parametric studies are conducted. 3D printing and laser cutting is used during prototyping. Finally, comparison of the analytical, computational and experimental frequency response results is held for validation. In conclusion, a very wide phononic band is obtained with w1/w2=0.221.

Benzer Tezler

  1. Deprem etkisindeki yapıların aktif kontrolü

    Active control of structures under seismic excitation

    BEKİR BORA GÖZÜKIZIL

    Yüksek Lisans

    Türkçe

    Türkçe

    2000

    İnşaat Mühendisliğiİstanbul Teknik Üniversitesi

    DOÇ.DR. NECMETTİN GÜNDÜZ

  2. Yapısal kontrol sistemleri ve sıvı sönümleyicilerin yapılarda kullanımı

    Structural control systems and the use of liquid dampers on the structures

    ERSAN SANSARCI

    Yüksek Lisans

    Türkçe

    Türkçe

    2002

    İnşaat Mühendisliğiİstanbul Teknik Üniversitesi

    Yapı Mühendisliği Ana Bilim Dalı

    DOÇ. DR. A. NECMETTİN GÜNDÜZ

  3. Deprem etkilerine karşı geliştirilen pasif ve aktif kontrol sistemleri

    Başlık çevirisi yok

    MELTEM ŞAHİN

    Yüksek Lisans

    Türkçe

    Türkçe

    1996

    İnşaat Mühendisliğiİstanbul Teknik Üniversitesi

    DOÇ.DR. NECMETTİN GÜNDÜZ

  4. Aktif ve pasif yapı kontrolü

    Active and passive structural control systems

    ÖZGÜL ZOBU

    Yüksek Lisans

    Türkçe

    Türkçe

    1997

    İnşaat Mühendisliğiİstanbul Teknik Üniversitesi

    Yapı Ana Bilim Dalı

    DOÇ. DR. A. NECMETTİN GÜNDÜZ