Geri Dön

Yüksek enerjili elektronlara ait dozların teknik rapor serisi 398 kalibrasyon protokolüne göre paralel plan ve silindirik iyon odaları ile karşılaştırılması

Comparison of high energy electron dose with parallel plan and cylindrical ion chamber according to technical report series 398 calibration protocol

  1. Tez No: 531082
  2. Yazar: PINAR HARMANKAYA
  3. Danışmanlar: DOÇ. DR. SENEM ALANYALI
  4. Tez Türü: Yüksek Lisans
  5. Konular: Onkoloji, Fizik ve Fizik Mühendisliği, Oncology, Physics and Physics Engineering
  6. Anahtar Kelimeler: Doz Kalibrasyon, TRS 398, Çapraz Kalibrasyon, Silindirik-Paralel Plan İyon Odası, Doz tayini, Doz-cevap ilişkisi-radyasyon, Parçacık hızlandırıcılar, Radyasyon, Radyasyon dozajı, Radyasyon etkileri, Radyasyon onkolojisi, İyon odası, Dose calibration, TRS398, Cross Calibration, Cylindrical-Parallel Plan Ion Chamber, Dose determination, Dose-response relationship-radiation, Particle accelerators, Radiation, Radiation dosage, Radiation effects, Radiation oncology, Ionization chamber
  7. Yıl: 2018
  8. Dil: Türkçe
  9. Üniversite: Ege Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Radyasyon Onkolojisi Ana Bilim Dalı
  12. Bilim Dalı: Sağlık Fiziği Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmanın amacı; TRS 398 kalibrasyon protokolüne göre yüksek enerjili elektronların doz kalibrasyonunda kullanılan paralel plan ve silindirik iyon odalarının enerjiye ve kullanılan iyon odası tipine göre doza etkisinin incelenmesidir. TRS 398 doz kalibrasyon protokolünde 10 MeV ve üzeri elektron enerjilerinde silindirik veya paralel plan iyon odası, 10 Mev altındaki enerjilerde ise paralel plan iyon odasının kullanılması önerilmektedir. Çalışmamızda Lineer hızlandırıcı cihazında bulunan 4, 6, 9, 12 ve 15 MeV enerjiye sahip 5 farklı elektron enerjisi kullanılmış ve bu elektron enerjileri için kalibrasyon işlemleri yapılmıştır. Doz kalibrasyon işlemlerine başlamadan öncelikle cihazın tüm mekanik kontrolleri yapılmış, ardından su fantomu yardımıyla dozimetrik kontrolleri de yapıldıktan sonra ölçümlere başlanmıştır. TRS 398 doz kalibrasyon protokolüne göre referans koşullarda her bir elektron enerjisi için ayrı ayrı su fantomu taramaları paralel plan iyon odası ile yapılıp hesaplamada kullanılacak yüzde derin doz eğrileri elde edilmiştir. Daha sonra protokolde yer alan düzeltme faktörlerinin hesabı için kullanılmak üzere verilerin alınması için silindirik ve paralel plan iyon odaları ile ışınlamalar yapılıp gerekli okuma değerleri alınmıştır. Ardından silindirik iyon odası yardımıyla paralel plan iyon odasına, en yüksek enerjiye sahip elektron için çapraz kalibrasyon yapılıp, paralel plan iyon odasına ait kalibrasyon faktörü hesaplanmıştır. Bu veri ve elde edilen diğer veriler yardımıyla hem paralel plan hem de silindirik iyon odası için her enerji değerindeki elektron için suda absorbe doz verileri hesaplanmıştır. Son olarak da bu hesaplanan dozlar arasındaki farklılıklar değerlendirilmiştir. Yapılan bu çalışmada elektronların kalibrasyonlarında kullanılan silindirik ve paralel plan iyon odaları ile yapılan ölçümlerdeki doz farkının silindirik iyon odası için 4 MeV için %-2.61, 6 MeV için %-0.90, 9 MeV için %-0.40, 12 MeV için %-0.15 ve 15 MeV için %0 olduğu saptanmış ve yüksek enerjiye sahip elektronlarda bu farkın az, buna karşın düşük enerjiye sahip elektronlarda ise bu farkın daha fazla olduğu görülmüştür. Çalışmamızda yüksek enerjili elektronlarda yapılan dozimetrik ölçümlerde TRS 398 numaralı protokolünde önerdiği gibi kalibrasyon işlemlerinde 10 MeV ve üstü elektron enerjileri için silindirik veya paralel plan iyon odasının kullanımın, 10 MeV altı enerjiye sahip elektronlar için ise paralel plan iyon odasının kullanımın uygun olduğu teyit edilmiştir.

Özet (Çeviri)

The purpose of this study is; According to the TRS 398 calibration protocol, parallel plate and cylindrical ion chambers used for dose calibration of high energetic electrons are used to examine the effect of doping according to the type of energy used and ion chamber. The TRS 398 dose calibration protocol recommends using a cylindrical planar ion chamber or parallel planar ion chamber at 10 MeV or above and at electron energies and a parallel plan ion chamber at energies below 10 MeV. In our study, 5 different electron energies with 4, 6, 9, 12 and 15 MeV energies were used in the linear accelerator and calibration processes were performed for these electron energies. Dosimetric controls with water phantom were also started after the measurements of all mechanical controls of the device were made before the dose calibration procedures were started. According to the TRS 398 dose calibration protocol, in the reference conditions, separate water phantom scans for each electron energy are made with a parallel plan ion chamber and the percent depth dose curves to be used in the calculation are obtained. Then, to obtain the data to be used for the calculation of the correction factors included in the protocol, cylindrical and parallel plan ion chambers were irradiated and required readings were taken. Then, by using the cylindrical ion chamber, cross calibration for the electron with the highest energy is performed to the parallel plan ion chamber and the calibration factor for the parallel plan ion chamber is calculated. With this data and other data obtained, absorptive dose data in water for each electron in each energy value was calculated for both parallel plan and cylindrical ion chamber.Finally, the differences between these calculated doses were evaluated. In this study, the dose difference in the measurements made with the cylindrical and parallel planar ion chambers used in the calibrations of electrons is %-2.61 for 4 MeV, %-0.90 for 6 MeV, %-0.40 for 9 MeV, %-0.15 for 12 MeV and %0 for 15 MeV, and this difference is less in electrons with higher energies, whereas it is found to be higher in electrons with lower energies. At the end of the study, it was found that the use of a cylindrical or parallel planar ion chamber for electron energies of 10 MeV and above and a parallel plan ion chamber for electrons of less than 10 MeV are suitable for calibration of dosimetric measurements with high energy electrons as suggested in TRS 398 protocol.

Benzer Tezler

  1. Bir ilaç fabrikasında personel gereksinmesinin belirmesi seçilmesi ve elde tutulmasına yönelik bir uygulama çalışması

    Başlık çevirisi yok

    EMİNE BOZBAĞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1989

    İstanbul Üniversitesi

    Çalışma Ekonomisi ve Endüstri İlişkileri Ana Bilim Dalı

    Yükleniyor...

  2. Çimentonun sertleşmesi üzerinde kimyasal komponentlerin etkisi

    Başlık çevirisi yok

    NACİYE TÜRKEL

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Uludağ Üniversitesi

    Kimya Ana Bilim Dalı

    Yükleniyor...

  3. Halvetiyyenin Şa'baniyye kolu ve Şa'ban-ı Veli

    Başlık çevirisi yok

    L. NİHAL YAZAR

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Gazi Üniversitesi

    Yükleniyor...

  4. Bazı esterlerin kinetik incelenmesi ve termodinamik parametrelerin belirlenmesi

    Kinetic study and detesmination of thermodnamic parameters of some esters

    İBRAHİM TAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Uludağ Üniversitesi

    Kimya Ana Bilim Dalı

    Yükleniyor...

  5. İzmir'de bazı yolların kapatılarak yaya bölgeleri oluşturma da kent peyzajını geliştirme açısından yeniden planlanması üzerinde araştırmalar

    Başlık çevirisi yok

    BAHAR TÜRKYILMAZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Şehir ve Bölge Planlama Ana Bilim Dalı

    Yükleniyor...