Mekanik hasar oluşturulan kondrosit kültürüne terapötik ultrasonun etkinliği
The effectiveness of therapeutic ultrasound to the mechanically damaged chondrocyte culture
- Tez No: 548922
- Danışmanlar: PROF. DR. ÖMER FARUK ŞENDUR
- Tez Türü: Tıpta Uzmanlık
- Konular: Fiziksel Tıp ve Rehabilitasyon, Physical Medicine and Rehabilitation
- Anahtar Kelimeler: Osteoartrit, Ultrason, Kondrosit, Osteoarthritis, Ultrasound, Chondrocyte
- Yıl: 2018
- Dil: Türkçe
- Üniversite: Adnan Menderes Üniversitesi
- Enstitü: Tıp Fakültesi
- Ana Bilim Dalı: Fiziksel Tıp ve Rehabilitasyon Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 70
Özet
MEKANİK HASAR OLUŞTURULAN KONDROSİT KÜLTÜRÜNE TERAPÖTİK ULTRASONUN ETKİNLİĞİ Amaç: Bu çalışmada düşük yoğunluklu kesikli ultrasonun, mekanik olarak hasar verilen kondrosit hücrelerine farklı doz ve sürelerde uygulanarak, kondrosit proliferasyonu ve migrasyonu üzerindeki etkinliğinin değerlendirilmesi amaçlandı. Gereç ve Yöntem: Çalışmada insan kaynaklı kondrosit (CHON-001 ATCC CRL-2846) hücresi kullanıldı. Kondrosit hücreleri uygun besiyerinde üretilerek hücre kültür petri kabına ekimi yapıldı. Ardından mekanik hasar verilerek ultrason uygulamasına geçildi. Çalışmanın ilk aşamasında beş dakika süreyle farklı yoğunluklarda kesikli ultrason uygulaması yapıldı. Sonrasında ise en uygun uygulama süresinin belirleneceği ikinci aşamaya geçildi. Kondrosit hücrelerinin hasarlı bölgedeki migrasyon ve proliferasyon hızlarındaki değişim, yalnızca hasar verilen ancak ultrason uygulanmayan toplamda altı kontrol grubu ile karşılaştırıldı. İnvert mikroskobunda x4 büyütmede 0. 4. 8. 24. ve 48. saatlerde hücre migrasyonu izlenerek yara iyileşmesi fotoğraflandı ve Matlab isimli program kullanılarak migrasyon aralıkları ve proliferasyon oranları kantitatif olarak belirlendi. Bulgular: Çalışmada hasarlı alandaki kondrosit hücrelerinde, 0.1, 0.2, 0.3, 0.4 ve 0.5 Watt/cm2 dozlarda beş dakika süreyle düşük yoğunluklu kesikli ultrason uygulaması sonrasında, yalnızca 0.5 Watt/cm2 yoğunlukta uygulanan grupta 48. saatte kontrol grubuna göre proliferasyonda istatistiksel olarak anlamlı bir şekilde artış olduğu belirlendi. Diğer dozlarda proliferasyon ve migrasyonda anlamlı bir iyileşme saptanmadı. 0.5 Watt/cm2 yoğunlukta ve 2.5, 5, 7.5 ve 10 dakikalık sürelerle yapılan uygulamada, 10 dakikalık uygulama sonrası tüm saatlerde, 7.5 dakikalık uygulama sonrasında ise sadece 48. saatte proliferasyonda istatistiksel olarak anlamlı bir şekilde artış olduğu gözlendi. Ancak migrasyonda tüm sürelerde istatistiksel olarak anlamlı bir iyileşme saptanmadı. Sonuç: Çalışmamızda 0.5 Watt/cm2 yoğunlukta kesikli ultrason uygulamasının kondrosit proliferasyonunda etkili olduğu ve bu etkinin beş dakikadan uzun süreli uygulamada belirgin hale geldiği görülmüştür. Tüm doz ve sürelerde ise kondrosit migrasyonunda olumlu bir etki gösterilememiştir.
Özet (Çeviri)
THE EFFECTIVENESS OF THERAPEUTIC ULTRASOUND TO THE MECHANICALLY DAMAGED CHONDROCYTE CULTURE Purpose: The aim of this study was to evaluate the efficacy of low density pulsed ultrasound on chondrocyte proliferation and migration by applying different ultrasound intensities and durations to the mechanically damaged chondrocyte cells. Materials and Methods: Human source chondrocyte (CHON-001 ATCC CRL-2846) cell was used in the study. Chondrocyte cells were produced in appropriate medium and cultured in cell culture petri dish. Then, mechanical damage was applied and ultrasound application was started. In the first phase of the study, pulsed ultrasound was performed at different intensities for five minutes. Afterwards, to determine the most appropriate implementation period, it was passed to the second phase. The change in the migration and proliferation rates of the chondrocyte cells in the damaged area was compared with six control groups which were only given damage but not ultrasound. Cell migration was monitored at 0, 4, 24 and 48 hours at x4 magnification in inverted microscope. Wound healing was photographed and migration intervals and proliferation rates were determined quantitatively by using Matlab. Results: In the study, after the administration of low intensity pulsed ultrasound for five minutes at 0.1, 0.2, 0.3, 0.4, and 0.5 Watt/cm2 intensities, a statistically significant increase in proliferation compared to the control group at 48 hours was observed in the damaged area only at 0.5 watt/cm2 intensity. There was no significant improvement in proliferation and migration at other intensities. By applying 0.5 Watt/cm2 intensity for 2.5, 5, 7.5 and 10 minute periods of time, it was observed that there was a statistically significant increase in proliferation at all hours for 10 minutes of application, and only at 48 hours for 7.5 minutes of application. However, no statistically significant improvement was found in migration for all periods of time. Conclusion: In our study, it was observed that ultrasound application with 0.5 Watt/cm2 intensity was effective in chondrocyte proliferation and this effect became apparent in the application lasting more than five minutes. No positive effect on chondrocyte migration was observed in all intensities and durations.
Benzer Tezler
- Travmatik kalça çıkığı modeli oluşturulan sıçanlarda trombositden zengin plazmanın kondrosit iyileşmesi üzerine etkisi
The effect of platelet-rich plasma on chondrocyte healing traumatic dislocation of the hip in the rat model
TOKTAMIŞ SAVAŞ
Tıpta Uzmanlık
Türkçe
2020
Ortopedi ve TravmatolojiGaziantep ÜniversitesiOrtopedi ve Travmatoloji Ana Bilim Dalı
PROF. DR. ORHAN BÜYÜKBEBECİ
- Dekorin protein uygulamasının sıçan siyatik sinir iyileşmesi üzerine etkisi
Effect of decorin protein application on rat sciatic nerve healing
ALPER GEYİK
Tıpta Uzmanlık
Türkçe
2020
Plastik ve Rekonstrüktif CerrahiDokuz Eylül ÜniversitesiPlastik Rekonstrüktif ve Estetik Cerrahi Ana Bilim Dalı
PROF. DR. HALUK VAYVADA
- Trombositten zengin plazma uygulamasının dejenere olmuş kıkırdağa etkisi: İn vitro deneysel bir çalışma
The effect of platelet rich plasma on dejenerated cartilage: In vitro an experimental study
KEVSER BAYRAKTAR
Tıpta Uzmanlık
Türkçe
2014
Fiziksel Tıp ve RehabilitasyonAdnan Menderes ÜniversitesiFiziksel Tıp ve Rehabilitasyon Ana Bilim Dalı
PROF. DR. ÖMER FARUK ŞENDUR
- Tavşan rotator cuff yırtığı modelinde enjekte edilebilen trombositten zengin fibrin (I-PRF) ve konsantre büyüme faktörü (CGF) uygulamasının kemik-tendon iyileşmesine olan etkilerinin karşılaştırılması
Comparison of the effects of injectable platelet rich-fibrin (i-PRF) and concentrated growth factor (CGF) on bone and tendon healing in rabbit rotator cuff tear model
MEHMET EREN SÖZGEN
Tıpta Uzmanlık
Türkçe
2023
Ortopedi ve TravmatolojiPamukkale ÜniversitesiOrtopedi ve Travmatoloji Ana Bilim Dalı
DOÇ. DR. ALİ ÇAĞDAŞ YÖRÜKOĞLU
YRD. DOÇ. DR. MURAT SERKANT ÜNAL
- Ratlarda deneysel oluşturulan postoperatif intraabdominal ve peritoneal adezyon modelinde adezyonların önlenmesine intraperitoneal honokiol ve hiyaluronik asit/karboksimetil selüloz (Seprafilm® ) kullanımının karşılaştırmalı etkilerinin araştırılması
Comparative comparison of the use of intraperitoneal honokiol and hyaluronic acid/carboxymethyl cellulose (Seprafilm®) for the prevention of adhesions in the experimental postoperative intraabominal and peritoneal adhesion model in rats
İSMAİL İSLAM ÇOLAK
Tıpta Uzmanlık
Türkçe
2023
Genel CerrahiKahramanmaraş Sütçü İmam ÜniversitesiGenel Cerrahi Ana Bilim Dalı
DOÇ. DR. ARİF EMRE