Çevrimsel (run around) ısı geri kazanım sistemlerindekullanılan serpantinlerdeki boru dizilim çeşitlerinin toplamverime etkisinin incelenmesi
Investigation of the effect coil's pipe arrangement typeson total thermal efficiency in run around heat recovery system
- Tez No: 659749
- Danışmanlar: PROF. DR. MUSTAFA ATMACA
- Tez Türü: Yüksek Lisans
- Konular: Enerji, Energy
- Anahtar Kelimeler: İklimlendirme, Çevrimsel (Run Around) Isı Geri Kazanım Sistemi, Isıl Verimlilik, Serpantin Tasarım Parametreleri, Air Conditioning, Run Around Heat Recovery System, Thermal Efficiency, Coil's Design Parameters
- Yıl: 2021
- Dil: Türkçe
- Üniversite: Marmara Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 62
Özet
Hastane, temiz oda, laboratuvar gibi özel hijyen şartları gereken uygulamalarda üfleme ve emiş hatlarının birbirinden bağımsız olması sebebi ile çevrimsel (run around) ısı geri kazanım sistemleri sıkça tercih edilmektedir. İlk yatırım ve işletme maliyeti diğer ısı geri kazanım sistemlerine oranla daha yüksek olan bu sistemlerin ısıl verimlilik oranları ülkemizde son derece düşüktür. Bu çalışmada sistem verimini arttırmak amacı ile ısıl verimi doğrudan etkileyen serpantin boru dizilim şekilleri farklı coğrafik bölgelerde bulunan iller için incelenmiştir. Çalışma için özel olarak üretilen serpantinler deneysel olarak test edilip elde edilen sonuçlar ampirik ısı transferi formülleri yardımı ile özel olarak geliştirilen bir yazılım programına aktarılmıştır. Kullanılan programının ticari kaygı gütmeyen bağımsız kuruluşlarca test edilip sertifikalandırılmış olması çalışmada elde edilen bulguların teoriden çok gerçeklik olgusuna yakınlığının ispatı niteliğindedir. Yazılım programı aracılığı ile elde edilen bulgular grafiksel olarak karşılaştırılıp yorumlanmıştır. Çalışma kapsamındaki serpantinlerden ısıl verimlilikleri en yüksek olanlar her bir şehir için tespit edilmiştir. Bu vesile ile farklı şehirler için kullanılması önerilen serpantin tasarımlarının daha verimli sistemlerin hayata geçirilmesi adına bir katkı sunması amaçlanmaktadır.
Özet (Çeviri)
In ventilation and air conditioning applications which requiring special hygiene conditions such as hospitals, clean rooms and laboratories, run around heat recovery systems are frequently preferred due to the fact that the blowing and suction lines are independent from each other. The thermal efficiency rates of these systems, whose investment and operating costs are higher than the other heat recovery systems, are extremely low in our country. In this study, in order to increase the efficiency of the system, coil pipe alignment patterns that directly affect the thermal efficiency have been examined for cities where located in different geographical regions. Coils which specially produced for the study were tested experimentally and the results obtained were transferred to a specially developed software program with the help of empirical heat transfer formulas. The fact that the program used has been tested and certified by independent non-commercial organizations is a proof that the results used in the study are closer to reality rather than theory. The results which gain through the software program were compared graphically and interpreted. Among the coils in the study, the ones with the highest thermal efficiency were determined for each city. On this occasion, it is aimed to make contribution to the realization of more efficient systems with the coil designs recommended for use in different cities.
Benzer Tezler
- Treatability of aircraft deicing fluids (ADFs) by high-rate anaerobic systems: An investigation on biogas potential and energy recovery
Havalimanlarında ortaya çıkan buz çözücü sıvıların yüksek-hızlı anaerobik sistemlerde arıtılabilirliği: Biyogaz potansiyeli ve enerji geri kazanımının araştırılması
GİZEM ENGİZ
Yüksek Lisans
İngilizce
2018
Çevre Mühendisliğiİstanbul Teknik ÜniversitesiÇevre Mühendisliği Ana Bilim Dalı
DOÇ. DR. ÇİĞDEM GÖMEÇ
- Urbanization's role in shaping temperature records: Insights from İzmir, Türkiye
Sıcaklık rekorlarının şekillenmesinde kentleşmenin rolü: Türkiye, İzmir'den çıkarımlar
FATMA BAŞAK SAKA
Yüksek Lisans
İngilizce
2024
Meteorolojiİstanbul Teknik ÜniversitesiMeteoroloji Mühendisliği Ana Bilim Dalı
PROF. DR. YURDANUR ÜNAL
- Reconciling energy and carbon emission performance for sustainability
Sürdürülebilirlik için enerji ve karbon emisyon performansının değerlendirilmesi
EBRU TAŞTAN KESERCİ
Yüksek Lisans
İngilizce
2016
EkonomiTOBB Ekonomi ve Teknoloji Üniversitesiİktisat Ana Bilim Dalı
DOÇ. DR. BAHAR ÇELİKKOL ERBAŞ
- Sıfır enerjili konut binalarında ısı pompası ve PV uygulamalarının enerji performans yaşam döngüsü ve maliyet analizleri
Energy performance life cycle and cost analysis of heat pump and pv applications in zero energy residential buildings
MEHMET YILMAZ
Yüksek Lisans
Türkçe
2021
Enerjiİstanbul Teknik ÜniversitesiEnerji Bilim ve Teknoloji Ana Bilim Dalı
PROF. DR. HATİCE SÖZER
- Sürüdürülebilir mimarlıkta yenilenebilir enerji kaynaklarının kullanımı, kamu binalarında uygulama yöntemleri ve örneklerinin incelenmesi
Use of renewable energy resources in sustainable architecture, investigation of application methods and eample in public buildings
GÖKHAN TEKBIYIK
Yüksek Lisans
Türkçe
2018
EnerjiFatih Sultan Mehmet Vakıf ÜniversitesiMimarlık Ana Bilim Dalı
DR. ÖĞR. ÜYESİ UĞUR ÖZCAN