Geri Dön

Spinal anestezi ile seksiyo operasyonu olan gebelerin maternal serebral oksijenizasyonu ve transabdominal fetal oksijenizasyonunun, yenidoğan apgar skoru ve serebral oksijenizasyonu ile ilişkisi

Maternal cerebral oxygenization and transabdominal fetal oxygenization of pregnances with sexio operation under spinal anesthesia relationship with apgar score and cerebral oxygenization in the newborns

  1. Tez No: 663373
  2. Yazar: SÜLEYMAN ÖZKAHRAMAN
  3. Danışmanlar: PROF. DR. AYŞE SURHAN ÇINAR
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Anestezi ve Reanimasyon, Anesthesiology and Reanimation
  6. Anahtar Kelimeler: Sezaryen, serebral oksijenizasyon, fetal oksijenizasyon, APGAR skoru, Cesarean section, cerebral oxygenation, fetal oxygenation, APGAR score
  7. Yıl: 2021
  8. Dil: Türkçe
  9. Üniversite: Sağlık Bilimleri Üniversitesi
  10. Enstitü: İstanbul Şişli Hamidiye Etfal Eğitim ve Araştırma Hastanesi
  11. Ana Bilim Dalı: Anesteziyoloji ve Reanimasyon Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 70

Özet

Giriş ve Amaç: Sezaryen cerrahisi esnasında gebelerde spesifik komplikasyonlar gelişip anne ve bebek sağlığı etkilenebilir. Doğum öncesi dönemde yaşanacak bu hadiselerle plasenta hipoksik hale gelirse, fetüs için ciddi komplikasyonlara yol açabilecek hipoksi, serebral palsi, nörolojik sekeller ve ölüm görülebilir. Böylece fetusun oksijenlenme durumunun değerlendirilmesi için fetal durumun belirlenmesi kritik önemdedir. Yenidoğanlarda APGAR skorunun ve serebral oksijenizasyonun bozulmasının noninvaziv metodlarla erken tanısı ve erken müdahalesi fetal hipoksik hasarı önleyebilir, böylece bu hastalarda yenidoğan yoğun bakım yatışları, yenidoğan entübasyonu olası morbidite ve mortalite azaltılabilir. Çalışmamızda gebe hastalarda spinal anestezi altında Near İnfrared Spectrometry (NIRS) tekniği ile serebral ve transabdominal fetal oksijenizasyon ölçümlerinin yenidoğan APGAR skoru ve yenidoğan serebral oksijenizasyon ölçümleri ile ilişkisini araştırmayı amaçladık. Gereç ve Yöntem: S.B.Ü Şişli Hamidiye Etfal E.A.H Kadın Doğum Kliniğine başvuran ASA I-II grubu 18 yaş üstü, elektif sezaryen planlanan, spinal anestezi altında seksiyo operasyonu olacak hastalar prospektif olarak planlanarak çalışmaya kabul edildi. Power analiz sonucuna göre örneklem büyüklüğü alfa anlamlı seviyesi 0,05, beta 0,90 olarak 111 hasta belirlendi. Operasyon odasına alınan hastaların demografik verileri (yaş, boy, kilo, gebelik haftası) kaydedildi. Rutin monitorizasyonda kalp tepe atımı (KTA), ortalama arter basıncı (OAB), oksijen saturasyonu (SPO2), maternal serebral oksijenasyon (mcRSO2), transabdominal fetal oksijenizasyon (tRSO2) ile monitorize edilerek operasyon sonuna kadar takip edildi ve kaydedildi. Bulgular: Çalışmamızda mcRSO2 1.dk, 5.dk, 10.dk, 15.dk değerleri başlangıç değerine göre anlamlı düşük bulundu, ortalama arter basınç değişimi 1.dk, 5.dk, 10.dk, 15.dk değerleri anlamlı düşüktü, mcRSO2 ve OAB arasında anlamlı pozitif korelasyon (p 0.05) gözlenmemiştir. Sonuç: Spinal anestezi uygulanan gebelerde annede serebral ve transabdominal fetal oksijenizasyon bulgularının yenidoğan serebral oksijenizasyon değişiklikleri ile ilişkisi tespit edilmedi. Transabdominal fetal oksijenizasyon bulguları ile AGAR skoru arasında anlamlı korelasyon tespit edilmiştir.

Özet (Çeviri)

Introduction and objective: During the cesarian section, specific complications may develop in pregnant women, affecting both maternal and infant health. Hypoxia, cerebral palsy and neurological sequelae, which may lead to serious complications for the fetus, and death may occur if the placenta becomes hypoxic due to the complications in the prenatal period. Therefore, in order to evaluate the oxygenation status of the fetus determination of fetal status has critical importance. Early diagnosis and early intervention of APGAR score and impairment of cerebral oxygenation with noninvasive methods in newborns can prevent fetal hypoxic damage, thereby reducing neonatal intensive care admissions, neonatal intubation, possible morbidity and mortality in these patients. In our study, we aimed to investigate the relationship between the cerebral and transabdominal fetal oxygenation measurements by NIRS technique under spinal anesthesia and the measurements of APGAR score and cerebral oxygenation in the newborns. Materials and Methods: Patients in ASA I-II group, who were over 18 years of age, were planned for the elective cesarian section under spinal anesthesia, and who presented to the Health Sciences University, Sisli Hamidiye Etfal Training and Research Hospital Obstetrics and Gynecology Clinic, were planned prospectively and included in the study. According to the results of the power analysis, 111 patients were determined with the sample size alpha significant level of 0,05 and beta level as 0,90. The demographic data (age, height, weight, gestational week) of the patients taken to the operation room were recorded. In routine monitoring, peak heart rate (PHR), mean arterial pressure (MAP), oxygen saturation (SPO2), maternal cerebral oxygenation (mcRSO2) and transabdominal fetal oxygenation (tRSO2) were monitored until the end of the operation, and they were recorded. Results: In our study, the values of mcRSO2 at 1 min, 5 min, 10 min, 15 min were found to be significantly lower compared to the initial value. The mean arterial pressure change values at 1. min, 5 min, 10 min, 15 min were significantly lower. A significant positive correlation was observed between mcRSO2 and MAP (p 0.05). Conclusion: It was observed that the cerebral and transabdominal fetal oxygenation findings in mothers, who underwent spinal anesthesia, had no relationship with the cerebral oxygenation changes in the newborns. A significant correlation was found between transabdominal fetal oxygenation findings and the AGAR score.

Benzer Tezler

  1. Elektif sezaryen uygulanan hastalarda kardiyak parametreleri etkileyen faktörlerin araştırılması

    Investigation of factors affecting cardiac parameters in patients WHO undergoing elective cesarean section

    SERHAT TAŞKIN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2021

    Anestezi ve ReanimasyonFırat Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    DOÇ. DR. SİBEL ÖZCAN

  2. Sezaryen seksiyo operasyonu sonunda uygulanan transversali̇s fasya plan bloğu ve transversus abdomi̇ni̇s plan bloğunun postoperati̇f derlenme kali̇tesi̇ üzeri̇ne etki̇leri̇ni̇n karşılaştırılması

    Comparison between transversalis fascia plane block and transversus abdominis plane block on postoperative recovery in patients undergoing cesarean section surgery

    AHMET PINARBAŞI

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2023

    Anestezi ve ReanimasyonMuğla Sıtkı Koçman Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    DOÇ. DR. MELİKE KORKMAZ TOKER

  3. Elektif sezaryen seksiyo vakalarında genel ve spinal anestezinin hasta memnuniyeti açısından karşılaştırılması

    Comparing general and spinal anesthesia in terms of patient satisfaction in elective cesarean surgery

    CENGİZHAN YAVUZ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2015

    Anestezi ve ReanimasyonKahramanmaraş Sütçü İmam Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    YRD. DOÇ. DR. GÖKÇE GİŞİ

  4. Preeklamptik gebeliklerde beyin omurilik sıvısı nitrik oksit düzey değişiklikleri

    Başlık çevirisi yok

    ŞEYMA HASÇALIK

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2001

    Kadın Hastalıkları ve Doğumİnönü Üniversitesi

    Kadın Hastalıkları ve Doğum Ana Bilim Dalı

    YRD. DOÇ. DR. REMZİ GÖKDENİZ

  5. Spinal anestezi ile yapılan sezaryen operasyonlarında intratekal artikaine morfin eklenmesinin anestezi ve postoperatif analjezi üzerine etkisi

    The effects of morphine in addition to spinal articaine in caesarean section

    ADNAN YALDIZ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2012

    Anestezi ve ReanimasyonFatih Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    DOÇ. DR. MUHAMMET GÖZDEMİR