Polietereterketon materyalinin teleskobik tutucularda kullanımının incelenmesi

Investigation of the use of polyetereterketone material in telescopic retainers

  1. Tez No: 720209
  2. Yazar: KIYMET ÇALIK
  3. Danışmanlar: DR. ÖĞR. ÜYESİ IŞIL TURP
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Çift kuron, konus kuron, polietereterketon (PEEK), oklüzal aralık, tutuculuk kuvveti, aşınma, Double crown, conus crown, polyetheretherketone (PEEK), occlusal gap, retention force, wear
  7. Yıl: 2022
  8. Dil: Türkçe
  9. Üniversite: Bezm-i Alem Vakıf Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 127

Özet

Bu çalışmanın amacı Polietereterketon (PEEK) materyalinin teleskobik tutucularda kullanımının uzun dönem tutuculuk değerlerini ve yüzey aşınmalarını in vitro olarak incelemektir. Çalışmada 2° konus açısı kullanılmış olup, farklı primer kuron ile sekonder kuron materyalleri ile primer ve sekonder kuron arasında oklüzalde aralık oluşturulması değerlendirilmiştir. Beş grup incelenmiştir; 1-Zirkonya primer kuronAltın sekonder kuron (elektroşekillendirme ile üretilmiş), oklüzalde aralık yok (ZA); 2-Zirkonya primer kuron-PEEK sekonder kuron, oklüzalde aralık yok (ZP); 3- Zirkonya primer kuron-PEEK sekonder kuron, 100 µm oklüzal aralık (ZP100); 4-PEEK primer kuron-PEEK sekonder kuron, oklüzalde aralık yok (PP); 5- PEEK primer kuron-PEEK sekonder kuron, 100 µm oklüzal aralık (PP100) gruplarından toplam 50 örnek hazırlanmıştır (n=10). Tutuculuk ölçümleri başlangıç, 100, 500, 1000, 5000, 10,000 takma-çıkarma döngüsü sonrası değerlendirilen gruplara, 50 N ön yük uygulanmıştır. Tüm takma-çıkarma deneyleri ve tutuculuk kuvveti ölçümleri yapay tükürük içerisinde gerçekleştirilmiştir. Deneyler sonunda her gruptan seçilen bir çift primer ve sekonder kuron ile aynı gruba ait ve hiç deneye girmemiş bir çift primer ve sekonder kuron, yüzeyindeki aşınmaları değerlendirmek için Taramalı Elektron Mikroskobu (SEM) ile incelenmiştir. En yüksek tutuculuk değerleri başlangıçta ve 10,000 döngü sonrasında PP100 grubunda (36,04-35,73 N), en düşük değerler ise ZA (9,05-15,06 N) grubunda saptanmıştır. Primer ve sekonder kuron arasında oklüzalde aralık oluşturulması, PEEK primer kuron ve PEEK sekonder kuron materyal çifti için 10.000 döngü sonunda tutuculuk değerlerini arttırmıştır. Deneyler sonrasında PEEK primer kuronlarda, PEEK sekonder kuronlarda ve altın sekonder kuronlarda aşınmalar gözlenirken zirkonya primer kuronlarda aşınma gözlenmemiştir. Çalışmadaki tutuculuk değerleri, klinik olarak kabul edilebilir 5-10 N değerlerinden yüksek olup sadece ZA ve ZP100 gruplarında başlangıçta elde edilen değerler bu aralıktadır. PP100 grubunda, 10 yıllık klinik kullanımı temsil eden süreç boyunca yeterli ve öngörülebilir tutuculuk kuvveti değerleri elde edilmiştir.

Özet (Çeviri)

The aim of this study is to evaluation the long-term retention values and surface wear of the Polyetheretherketone (PEEK) material in telescopic retainers in vitro. A conus angle of 2° was used, and the formation of an occlusal gap between the primary and secondary crowns with different primary crown and secondary crown materials was evaluated. Five groups were investigated; 1-Zirconia primary crownGold secondary crown (manufactured by electroforming), no occlusal gap (ZA); 2- Zirconia primary crown-PEEK secondary crown, no occlusal gap (ZP); 3-Zirconia primary crown-PEEK secondary crown, 100 µm occlusal gap (ZP100); 4-PEEK primary crown-PEEK secondary crown, no occlusal gap (PP); 5-PEEK primary crown-PEEK secondary crown, 100 µm occlusal gap (PP100). A total of 50 samples were prepared from the groups (n=10). A preload of 50 N was applied when the retention force measurements were measured initially and after 100, 500, 1000, 5000, 10,000 cycles of insertion-seperation cycles. All insertion-seperation cycles and retention force measurements were carried out in artificial saliva. A pair of primary and secondary crowns selected from each group and double crowns that were not subjected to insertion-seperation cycles were examined by Scanning Electron Microscopy (SEM) to evaluate the wear on their surface. The highest retention values were estimated in the PP100 group (36.04-35.73 N) at the beginning and after 10,000 cycles, and the lowest values were estimated in the ZA (9.05-15.06 N) group. Formation of an occlusal gap between the primary and secondary crowns increased the retention force values after 10,000 cycles for the PEEK primary crown and PEEK secondary crown material couple. After the experiments, wear was observed on PEEK primary crowns, PEEK secondary crowns and gold secondary crowns, while no wear was observed on zirconia primary crowns. The retention values in the study were higher than the clinically acceptable range of 5- 10 N values, and only the values initially obtained in the ZA and ZP100 groups were in this range. In the PP100 group, adequate and predictable retention force values were obtained throughout the period representing 10 years of clinical use.

Benzer Tezler

  1. Polietereterketon polimer yüzeyine farklı yüzey işlemi uygulamalarının kompozit rezin ve rezin siman bağlantısına etkilerinin değerlendirilmesi

    Evaluation of the effect of different surface treatments to polyetereterketone polymer surface on composite resin and resin cement bonding

    AYŞEGÜL HAZIR

    Doktora

    Türkçe

    Türkçe

    2022

    Diş HekimliğiKırıkkale Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. SAADET ATSÜ

    PROF. DR. YASEMİN KESKİN

  2. İki farklı tip peek materyalinin kompozitle bağlanma dayanımının değerlendirilmesi

    Evaluation of bond strength Two different peek and indirect composite resin materials

    ZIYA SAFARLI

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2019

    Diş HekimliğiKocaeli Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. SERKAN SARIDAĞ

  3. Farklı yüzey temizleme işlemi uygulanmış güncel termoplastik kaide materyalinin yüzey pürüzlülüğü ve renk değişiminin incelenmesi

    Investigation of surface roughness and color stability of the current thermoplastic denture base material with different surface cleaning process

    ÜMMÜ HABİBE ERDAĞ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2020

    Diş HekimliğiZonguldak Bülent Ecevit Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. ONUR ŞAHİN

  4. Altyapı materyali olarak kullanılan polietereterketon ve polieterketonketon materyallerinin bükülme dayanıklılığının karşılaştırmalı incelenmesi

    Comparison of flexural strength of polyetheretherketone and polyetherketonketone core materials

    MERAL BAĞKUR

    Doktora

    Türkçe

    Türkçe

    2019

    Diş HekimliğiGazi Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. TURGUT CİHAN AKÇABOY

  5. Lomber TLİF (transforaminal lomber interbody füzyon) uygulamasında PEEK (polietereterketon Kafes ve Otolog Lamina Greftlerinin (OLG), radyolojik ve klinik olarak değerlendirilmesi

    Radiological and Clinical Evaluation of PEEK polyetheretherketone) Cages and Autologous Lamina Grafts (ALG)in Lumbar TLIF (transforaminal lumbar interbody fusion) Technique

    HAKAN DEMİRCİ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2013

    NöroşirürjiSağlık Bakanlığı

    Ruh Sağlığı ve Hastalıkları Ana Bilim Dalı

    DR. ALİ ENDER OFLUOĞLU