Geri Dön

Petrol rafinerisi fenolik atıksularının foto-fenton prosesi ile arıtılabilirliği

Removal of phenol from oil refinery phenolic wastewater with photo-fenton-uvc254 process

  1. Tez No: 760086
  2. Yazar: FATİH GÜLMEZ
  3. Danışmanlar: DOÇ. DR. ESRA CAN DOĞAN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Çevre Mühendisliği, Environmental Engineering
  6. Anahtar Kelimeler: Atık su, Fenolik bileşikler, Petrol rafinerileri, Su kirliliği, Taguchi deneyleri, Waste water, Phenolic compounds, Petroleum rafineries, Water pollution, Taguchi experiments
  7. Yıl: 2022
  8. Dil: Türkçe
  9. Üniversite: Kocaeli Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Çevre Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Çevre Mühendisliği Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Petrol rafineri endüstrisinde bir birim ham petrolün rafinajı için 0,4 ile 1,6 birim arasında değişen miktarlarda proses suyu kullanılmaktadır ve bu oranda atık su oluşmaktadır. Geciktirilmiş koklaştırma ünitesinden gönderilen yüksek fenol içerikli atıksulara mikrobiyolojik aktivite üzerindeki inhibe edici etkisi sebebiyle 1/10 oranında yağlı atık su ile seyreltme uygulanmaktadır. Bu çalışmada; pH: 10,2, fenol: 80,6 mg/L, KOİ: 1682 mg/L, toplam siyanür: 6 mg/L, yağ ve gres: 12,2 mg/L, S-2: 0,172 mg/L and NH4-N: 360 mg/L karakterizasyonuna sahip gerçek bir petrol rafinerisi fenolik sıyrılmış atıksularından foto-Fenton-UVC254 prosesi ile fenol giderimi performansı laboratuvar ölçekli olarak araştırılmıştır. Taguchi deneysel tasarımı kullanılarak reaksiyon süresi (60, 90, 120 dak), H2O2/Fenol oranı (5, 7,5, 10), H2O2/Fe+2 oranı (5, 10, 15) ve ışık şiddeti (UVC lamba sayısı: 2, 3, 4) parametrelerinin fenol giderim performansı üzerine etkisi incelenmiş, fenol giderim performansı sonuçları cevap yüzey yöntemi ile değerlendirilmiştir. Optimum koşullarda (reaksiyon süresi: 120 dak; H2O2/Fenol: 10; H2O2/Fe+2: 5 ve lamba sayısı: 4) yürütülen foto-Fenton prosesi sonucu arıtılmış su fenol değeri 4,89 mg/L değerine düşürülerek %94'lük giderim verimi elde edilmiştir. Sonuç olarak, foto-Fenton prosesinin fenol, sülfür, siyanür, yağ ve gres gideriminde etkili olduğuna karar verilmiş ve arıtılmış suyun pH ayarlaması (6-9) yapıldıktan sonra seyreltme ihtiyacı olmadan aktif çamur sistemine beslenebileceği tespit edilmiştir. İlave olarak, daha yüksek Fe+2 ve H2O2 konsantrasyonları ve daha uzun reaksiyon süreli foto-Fenton uygulamaları ya da foto-Fenton prosesinden sonra membran prosesi kullanımı gibi alternatif uygulamalarla da arıtılmış suyun doğrudan deniz deşarjı ya da atık su geri kazanım ünitesi beslemesi için değerlendirilebileceği görülmüştür.

Özet (Çeviri)

In oil refining industry; for one unit of crude oil refining, between 0.4 and 1.6 units of process water is needed. Wastewater with high phenol concentration, formed in the delayed coker units, causes a high inhibition effect on microbiological activity. Therefore, it is diluted 1/10 with oily wastewater to treat in the activated sludge system. In this study; phenol removal performance of photo-Fenton-UVC254 process from phenolic stripped real refinery wastewater having characteristics of pH: 10.2, phenol: 80.6 mg/L, COD: 1682 mg/L, total cyanide: 6 mg/L, oil-grease: 12.2 mg/L, S-2: 0.172 mg/L and NH4+-N: 360 mg/L has been investigated at laboratory scale. Experiments were planned with Taguchi experimental design and process time (60, 90, 120 min), H2O2/Phenol rate (5, 7.5, 10), H2O2/Fe+2 rate (5, 10, 15) and light intensity (number of UVC lamps: 2, 3, 4) parameters on phenol removal were investigated, then evaluated by response surface methodology. The effluent phenol value was reduced to 4.89 mg/L with 94% removal efficiency with photo-Fenton process under optimum conditions (process time: 120 minutes; H2O2/Phenol: 10; H2O2/Fe+2: 5 and number of lights: 4). Consequencely, it was determined the photo-Fenton process is very effective in removing phenol, sulfur, cyanide and oil-grease and the effluent can be fed into the activated sludge system without dilution after adjusting pH to 6-9. Additionally, with alternative applications such as longer-term photo-Fenton application with higher iron and H2O2 or the use of membrane processes after photo-Fenton, the treated water can be sent to the wastewater recovery unit or deep sea discharge.

Benzer Tezler

  1. Şırnak asfaltitleri külünde nikel ve molibdenin spektrofotometrik tayini

    Spectrophotometric determination of nickel and molybdenum in Şırnak asphaltites ash

    OLCAY ŞİMŞEK

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Petrol ve Doğal Gaz MühendisliğiGazi Üniversitesi

    YRD. DOÇ. DR. ALİ REHBER TÜRKER

  2. Türkiye'de planlı dönemde çiftçinin satın alma gücündeki değişimler, bu değişmelerin nedenleri ve konu ile ilgili bazı görüşler

    Başlık çevirisi yok

    FULYA DUYAN

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    ZiraatEge Üniversitesi

    Tarım Ekonomisi Ana Bilim Dalı

    DOÇ. DR. LATİF ÇAĞLAYAN

  3. Isı değiştirgeç ağlarının optimum sentezi

    Başlık çevirisi yok

    SERAP CESUR

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Kimya MühendisliğiEge Üniversitesi

    Kimya Mühendisliği Ana Bilim Dalı

    DOÇ. DR. BENO KURYEL

  4. İran ekonomisi (1973-1983)

    Başlık çevirisi yok

    ABDULLAH GİTİ BOSTANABAD

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    EkonomiGazi Üniversitesi
  5. Antalya-Korkuteli yöresinde gübresiz ve sulamasız koşullarda yetiştirilen altunbaş kavun çeşidinde bitki besin maddelerinin ve jetasyon süresince değişimleri ve verim ile kaliteye etkileri

    Seasonal variations and the effects of nutrients on yield and guality characteristics of sugar melon in Antalya-Korkuteli Region

    ATİLA ÜNAL

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    ZiraatEge Üniversitesi

    YRD. DOÇ. DR. MÜZEYYEN SEÇER

  6. Petrol ihraç eden Arap ülkelerine bir örnek Libya

    Başlık çevirisi yok

    HÜSEYİN AHMET ALİ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    EkonomiGazi Üniversitesi