Yenidoğan yoğun bakım ünitesi için gürültü önleme standardının geliştirilmesi ve sağlık profesyonellerinin uyumu ile yenidoğan konforuna etkisinin belirlenmesi

Developing the noise prevention standard for the neonatal intensive care unit and determining the adaptation of HEALTH professionals and its effect on newborn comfort

  1. Tez No: 788346
  2. Yazar: GÜNAY ARSLAN
  3. Danışmanlar: DOÇ. DR. ÇAĞRI ÇÖVENER ÖZÇELİK
  4. Tez Türü: Doktora
  5. Konular: Çocuk Sağlığı ve Hastalıkları, Hemşirelik, Child Health and Diseases, Nursing
  6. Anahtar Kelimeler: yenidogan, gürültü, yogun bakim, standart, Bebek-yenidoğmuş, Bebek-yenidoğmuş hastalıkları, Gürültü kirliliği, Gürültü yalıtımı, Konfor, Sağlık personeli, Yoğun bakım üniteleri-neonatal, newborn, noise, intensive care, standard, Infant-newborn, Infant-newborn diseases, Noise pollution, Noise isolation, Comfort, Health personnel, Intensive care units-neonatal
  7. Yıl: 2023
  8. Dil: Türkçe
  9. Üniversite: Marmara Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Hemşirelik Ana Bilim Dalı
  12. Bilim Dalı: Çocuk Sağlığı ve Hastalıkları Hemşireliği Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Araştırma, yenidoğan yoğun bakım ünitelerinde ortak bir dil oluşturulması ve her çalışanın bu doğrultuda hareket etmesi için yenidoğan yoğun bakım ünitelerine özgü bir gürültü önleme standartının geliştirilmesi amacıyla yapılmıştır. Yöntem: Tek grupta ön test-son test tasarımında yarı deneysel olarak gerekleştiririlen araştırmanın evrenini yenidoğan yoğun bakım ünitesinde görevli sağlık profesyonelleri (Hemşire, Hekim ve Ebeler) oluşturmuştur (n=42) ile 26 yenidoğan oluşturmuştur. Araştırmada üniteye özgü gürültü önleme standartı geliştirilmiş; konuyla ilgili eğitim verilmiş ve küvözlere gürültü kontrol cihazı yerleştirilmiştir. Eğitim öncesi ve sonrası gürültü önleme standartına uyum değerlendirilmiştir. Planlı ve plansız saatlerde gürültü seviyesi, nedeni ve cihazı uyarı veren küvöz de bulunan yenidoğanın yaşam bulguları ve konfor düzeyi kayıt edilmiştir. Sağlık profesyonelleri ise standarda uyum açısından araştırmacı ve yardımcı araştırmacı tarafından birbirlerinden bağımsız olarak değerlendirilmiştir. Bulgular: Çalışmanın bulgularına göre sağlık profesyonellerinin eğitim öncesi ve eğitim sonrası standarda uyum puanları arasında istatistiksel olarak ileri derecede anlamlı bir fark olduğu görülmektedir (p<0.001). Eğitim sonrası standarda uyum puanları eğitim öncesi puanlarına göre daha yüksek olarak saptanmıştır. Sağlık profesyonellerinin standarta uyumlarının artmasına ve gürültünün azalmasına karşın gürültünün yenidoğanların fizyolojik parametreleri (yenidoğanların kan basıncı, kalp atım hızı, SpO2, solunum sayısı, vücut ısısı) ve konfor puanına etkisi planlı ölçümlerle karşılaştırıldığında istatistiksel olarak anlamlı bir fark yaratmamıştır (p>0,05) ancak ortalama değerlerde düşüş görülmüştür. Plansız ölçümlerde ise eğitim sonrası ünitedeki standarta uyum arttığı ve gürültü azaldığı için yenidoğan fizyolojik parametreleri ve konforu olumlu yönde etkilendiği saptanmıştır. Sonuç: Bu çalışmada sağlık profesyonelleri için gürültü önleme standardı geliştirilmiş; standartın uygulanışı ve gürültü hakkında eğitim verilerek standarda uyum arttırılmış ve gürültü azaltmıştır.

Özet (Çeviri)

Program Name: Marmara University Health Sciences Institute Nursing Doctorate Program Objective: The research was carried out in order to create a common language in neonatal intensive care units and to develop a noise prevention standard specific to neonatal intensive care units in order for each employee to act in this direction. Material and Method: The population of the study, which was carried out as a quasi-experimental in the pre-test-post-test design in a single group, consisted of health professionals (Nurses, Physicians and Midwives) working in the neonatal intensive care unit (n=42) and 26 newborns. In the research, a unit-specific noise prevention standard was developed; training was given on the subject and a noise control device was placed in the incubators. Compliance with the noise prevention standard was evaluated before and after the training.The vital signs and comfort level of the newborn, who was in the incubator with the noise level, cause and device warning during scheduled and unplanned hours, were recorded. Health professionals, on the other hand, were evaluated independently by the researcher and the assistant researcher in terms of compliance with the standard. Results: According to the results of the study, it was seen that there was a statistically significant difference between the standard compliance scores of health professionals before and after education (p<0.001). The scores of compliance with the standard after the training were found to be higher than the scores before the training. Despite the increase in the compliance of health professionals with the standard and the decrease in noise, the effect of noise on the physiological parameters of newborns (newborns' blood pressure, heart rate, SpO2, respiratory rate, body temperature) and comfort score did not make a statistically significant difference when compared with planned measurements (p>0.05). However, a decrease was observed in the mean values. In the unplanned measurements, it was determined that the newborn's physiological parameters and comfort were positively affected as the compliance with the standard in the unit increased and the noise decreased after the training. Conclusion: In this study, a noise prevention standard was developed for healthcare professionals; compliance with the standard was increased and noise was reduced by providing training on the implementation of the standard and noise.

Benzer Tezler

  1. Yenidoğan yoğun bakım ünitesinde verilen eğitimin ünitenin gürültü düzeyine ve hemşirelerin farkındalık düzeylerine etkisi

    The effect of education given to nurses in the neonatal intensive care unit on the noise level of the unit and nurses' awareness levels

    CEREN KOLTAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    HemşirelikEge Üniversitesi

    Çocuk Sağlığı ve Hastalıkları Hemşireliği Ana Bilim Dalı

    PROF. DR. DİDAR ZÜMRÜT BAŞBAKKAL

  2. Yenidoğan yoğun bakım ortamında gürültü ve aydınlatma durumunun incelenmesi

    Examination of noise and lighting conditions in neonatal intensive care unit

    FADİME GAMZE TEKİN

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    HemşirelikAkdeniz Üniversitesi

    Hemşirelik Ana Bilim Dalı

    DOÇ. DR. EMİNE KOL

  3. Gürültü ve ışığı azaltmak için geliştirilen şapkanın, preterm yenidoğanın konforu üzerine etkisi

    Effect of the hat developed to reduce noise and light on the comfort of preterm newborn

    ÖZLEM AKARSU

    Doktora

    Türkçe

    Türkçe

    2020

    Çocuk Sağlığı ve Hastalıklarıİstanbul Üniversitesi-Cerrahpaşa

    Çocuk Sağlığı ve Hastalıkları Hemşireliği Ana Bilim Dalı

    DOÇ. DR. SERAP BALCI

  4. Prematüre yenidoğanlarda topuktan kan alma işlemi sırasında anne sütü kokusu ve beyaz gürültü kullanımının ağrı yönetimine etkisinin değerlendirilmesi: Randomize kontrollü çalışma

    Evaluation of the effect of use of breast milk odor and white noise on pain management during heel lance in premature newborns: A randomized controlled study

    BURCU OTLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2023

    HemşirelikAnkara Üniversitesi

    Hemşirelik Ana Bilim Dalı

    DOÇ. DR. FİGEN IŞIK ESENAY

  5. Gürültüyü azaltan oksijen başlığı kullanımının pretermin oksijen satürasyonu, kalp tepe atımı ve uyku durumuna etkisi

    The effect of using noise reduction hood on oxygen saturation, heart rate and sleep state of preterm

    MÜJDE ÇALIKUŞU İNCEKAR

    Doktora

    Türkçe

    Türkçe

    2018

    Hemşirelikİstanbul Üniversitesi-Cerrahpaşa

    Çocuk Sağlığı ve Hastalıkları Hemşireliği Ana Bilim Dalı

    DOÇ. DR. DUYGU GÖZEN