Geri Dön

Biyokütle yakıtlı bir termik santralin enerji ve ekserji analizi

Energy and exergy analysis of a biomass fired thermal power plant

  1. Tez No: 793818
  2. Yazar: SULTAN BOYRAZ ÇETİN
  3. Danışmanlar: DR. ÖĞR. ÜYESİ HALİT LUTFİ YÜCEL
  4. Tez Türü: Yüksek Lisans
  5. Konular: Enerji, Energy
  6. Anahtar Kelimeler: Biyokütle, Akışkan yataklı reaktörler, Enerji verimliliği, Buhar kazanı, Termik santraller, Biomass, Fluidized bed reactors, Energy efficiency, Steam boiler, Thermal power plants
  7. Yıl: 2023
  8. Dil: Türkçe
  9. Üniversite: Fırat Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Enerji Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Yapılan bu çalışmada Malatya ilinde bulunan 66 ton/saat kapasiteli kızgın buhar üretimi sağlayarak 15,75 MW elektrik üretimi gerçekleştiren bir biyokütle yakıtlı termik santralin enerji ve ekserji analizi yapılmıştır. Hesaplamaları yapmak için düğüm noktaları belirlenmiştir ve bu noktaların basınç, sıcaklık, debisine göre termodinamik özellikleri tablolarda verilmiştir. Enerji analizi için 21 adet düğüm noktası belirtilerek en çok enerji kaybının 41588096 kW ile kazanda olduğu tespit edilmiştir. Ekserji kaybı için ise 16 adet düğüm noktası oluşturulup toplam ekserji kaybı 31942,5 kW olup, en çok ekserji kaybının 23978,4 kW ile kazanda görüldüğü buda toplam ekserji kaybının % 75 ine denk gelmektedir. Diğer ekipmanların enerji ve ekserji analizi yapılarak tablolar oluşturulmuştur. Santralin ısıl verimi % 68, 2. yasa verimi ise % 55 olarak bulunmuştur.

Özet (Çeviri)

The energy and exergy analysis of a biomass-fired thermal power plant in Malatya province, which produces 66 tons/hour of superheated steam and produces 15.75 MW of electricity, has been made. To make the calculations, nodal points were determined and given in the thermodynamic properties tables according to the pressure, temperature and flow rate of these points. For the energy analysis, it has been determined that the highest energy loss is in the boiler with 41588096 kW, which maintains 21 nodal points. For exergy loss, the formation of 16 nodes, the total exergy loss is 31942.5 kW, and the highest exergy loss is seen in the boiler with 23978.4 kW, which corresponds to 75% of the total exergy loss. Energy and exergy analysis configuration tables of other equipment. The thermal source of the power plant was found to be 68%, and the second source of life was 55%.

Benzer Tezler

  1. Kabarcıklı akışkan yataklı bir multi jenerasyon santralinin sanayide uygulanması ve termodinamik analizinin yapılması

    Thermodynamic analysis of a bubbling fluidized bed multi generation plant for industrial applications

    DUYGU GÜNDÜZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2013

    Gazi Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  2. Kuvvetli atıkların yukarı akışlı havasız filtrelerde arıtım kinetiği

    Kinetics of strong waste treatment by anqerobic upflow filters

    M.ATALAY TİMUR

    Doktora

    Türkçe

    Türkçe

    1986

    İstanbul Teknik Üniversitesi

    Yükleniyor...

  3. Kızılağaç (almus glutinosa geartnsubsp barbata (C.A.Mey) Yalt.) gövde hacim ve biyokütle tablolarının düzenlenmesi

    Başlık çevirisi yok

    NEDİM SARAÇOĞLU

    Doktora

    Türkçe

    Türkçe

    1988

    Karadeniz Teknik Üniversitesi

    Orman Mühendisliği Ana Bilim Dalı

    Yükleniyor...