Sıcaklığın akışkan kompozit rezin restoratif materyalin polimerizasyon büzülmesine etkisinin mikro bilgisayarlı tomografi ile incelenmesi
Investiation of the effect of temperature on polymerization shrinkage of flowable composite resin restorative material with micro computed tomography
- Tez No: 828443
- Danışmanlar: PROF. DR. PERİHAN ÖZYURT
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2023
- Dil: Türkçe
- Üniversite: Ankara Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Diş Hastalıkları ve Tedavisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 91
Özet
Bu çalışmanın amacı; farklı sıcaklıklarda bekletilen yeni geliştirilmiş bir akışkan kompozitte meydana gelen polimerizasyon büzülmesinin son model mikro bilgisayarlı tomografi (micro-CT) kullanılarak in vitro değerlendirilmesi sonucunda hangi sıcaklığın polimerizasyon büzülmesine daha fazla etkiliği olacağının saptanmasıdır. Aynı zamanda akışkan kompozit rezinlerin özellikleri hakkında literatüre bilgi aktarılması, bulguların bundan sonra yapılacak klinik uygulama ve çalışmalara katkı sağlaması amaçlanmıştır. Bu çalışmada kullanılan akışkan kompozit rezin (Clearfıl Majesty Flow, Kuraray Noritake Dental INC, Okuyama JAPAN) örnekler 4 farklı sıcaklıklarda (4°C ,20°C ,37°C ,55°C) değerlendirilmiştir. Akışkan kompozit materyali 4°C ,20°C ,37°C ,55°C lerde 30 dakika bekletildikten sonra 2mm derinlikte standart politetrafloroetilen (PTFE) kalıplar içine yerleştirilen 25şer örnek, ikişer dakika bulundukları sıcaklıklarda karanlık ortamda bekletilmiş ve polimerize edilmeden örnekler micro-CT (Skyscan 1275, Bruker USA) cihazında taranmıştır. Daha sonra örnekler, tarama sırasında oluşan ısı kaybını telafi etmek için tekrar ikişer dakika bulundukları sıcaklıkta karanlıkta bekletilmiş ve 20şer saniye ışık cihazı (BlueLEX GT-1200, Monitex Industrial Co., LTD, TAIWAN) kullanılarak polimerize edilmiştir. Polimerize edilen örnekler tekrar micro-CT'de taranmıştır. Veriler istatistiksel olarak değerlendirilmiştir. Tüm grupların polimerizasyon öncesi ve polimerizasyon sonrası ortalama hacim verileri karşılaştırıldığında 4°C en az polimerizasyon büzülmesi gözlemlenmiştir. Çalışmamızda 4°C en az polimerizasyon büzülmesi gösterirken bunu 20°C ve 37°C takip etmiştir. En fazla poimerizasyon büzülmesi ise 55°C'de gözlenmiştir. Polimerizasyon büzülmesine ilişkin ortalamalar arası farklılıkların araştırılması için yapılan testlerde polimerizasyon büzülmeleri açısından tüm sıcaklık dereceleri arasında istatistiksel olarak anlamlı bir fark saptanmamıştır (p > 0.05).
Özet (Çeviri)
The aim of this study is to determine which temperature will have more effect on polymerization shrinkage as a result of in vitro evaluation of polymerization shrinkage occurring in a newly developed flowable composite kept at different temperatures using the latest micro-computed tomography (micro-CT). At the same time, it is aimed to convey information about the properties of flowable composite resins to the literature and to contribute to the clinical applications and studies to be made from now on. The flowable composite resin (Clearfil Majesty Flow, Kuraray Noritake Dental INC, Okuyama JAPAN) samples used in this study were evaluated at 4 different temperatures (4°C ,20°C ,37°C ,55°C). After the flowable composites were kept at 4°C, 20°C, 37°C and 55°C for 30 minutes, 25 samples placed in standard polytetrafluoroethylene (PTFE) molds at a depth of 2mm were kept in the dark for two minutes at the same temperature and the samples were scanned in a micro-CT (Skyscan 1275, Bruker USA) device without polymerization. Then, to compensate for the heat loss during scanning, the samples were kept in the dark for two minutes at their current temperature and polymerized using a light device (BlueLEX GT-1200, Monitex Industrial Co., LTD, TAIWAN) for 20 seconds. The polymerized samples were scanned again in micro-CT. Data were statistically evaluated. When the average volume data of all groups before and after polymerization were compared, the least polymerization shrinkage at 4°C was observed. In our study, 4°C showed the least polymerization shrinkage, followed by 20°C and 37°C. The highest polymerization shrinkage was observed at 55 °C. In the tests performed to investigate the differences between the averages of polymerization shrinkage, no statistically significant difference was found between all temperatures in terms of polymerization shrinkage (p > 0.05).
Benzer Tezler
- Farklı restoratif materyallerin ozon gazı ve geleneksel kavite dezenfektanı uygulanmış dişlerde mikrosızıntıya olan etkisinin incelenmesi
Investigation of the effects on microleakage of ozone gas and traditional cavity disinfectant at teeth which are restorated with different restorative materials
ÖMER ÇELLİK
Diş Hekimliği Uzmanlık
Türkçe
2015
Diş HekimliğiDicle ÜniversitesiRestoratif Diş Tedavisi ve Endodonti Ana Bilim Dalı
DOÇ. DR. EMRULLAH BAHŞİ
- Endodontik tedavi sonrası aşırı harabiyete uğramış dişlerde kök kısımlarının değerlendirilmesi
Evaluation of root fractures in teeth that have suffered extreme damage after endodontic treatment
HALUK KURTULMUŞ
Doktora
Türkçe
2014
Diş Hekimliğiİstanbul ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. İBRAHİM BÜLENT ŞERMET
- Advanced thermosets from sulfur, renewable benzoxazine and ionones via inverse vulcanization
Ters vulkanizasyon yoluyla sulfur, yenilenebilir benzoksazin ve iyonon'dan gelişmiş termosetler
OZAN BAYRAM
Yüksek Lisans
İngilizce
2020
Kimyaİstanbul Teknik ÜniversitesiKimya Ana Bilim Dalı
DOÇ. DR. BARIŞ KIŞKAN
- Kompozit malzemelerin mekanik özelliklerine yaşlandırma parametrelerinin etkisinin araştırılması ve yanıt yüzey metodu ile optimizasyonu
Investigation of the effect of aging parameters on the mechanical properties of composite materials and optimization by response surface methodology
RAMAZAN ÖZTÜRK
Yüksek Lisans
Türkçe
2023
Makine MühendisliğiManisa Celal Bayar ÜniversitesiMakine ve İmalat Mühendisliği Ana Bilim Dalı
DR. ÖĞR. ÜYESİ HAMZA TAŞ
DOÇ. DR. İBRAHİM FADIL SOYKÖK
- Biyo-reçine esaslı tekstil kompozitlerinin performans özelliklerinin incelenmesi
Investigation of performance characteristics of bio-resin based textile composites
SEMİH ÖZKÜR
Yüksek Lisans
Türkçe
2021
Tekstil ve Tekstil Mühendisliğiİstanbul Teknik ÜniversitesiTekstil Mühendisliği Ana Bilim Dalı
DR. ÖĞR. ÜYESİ İPEK YALÇIN ENİŞ