Geri Dön

Ti ve Ti-500 implant materyallerinde, implantasyon sonrası oluşan TH1/TH2 sitokin yanıtlarının karşılaştırmalı analizi

Comparative analysis of TH1/TH2 cytokine responses after implantation of titanium and titanium-500 implant materials

  1. Tez No: 834465
  2. Yazar: KAAN CENGİZ
  3. Danışmanlar: PROF. DR. SİBEL AKYOL
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizyoloji, Physiology
  6. Anahtar Kelimeler: Biyouyumlu materyaller, Nikel-titanyum alaşımları, Sitokinler, Titanyum, İmmünositokinler, İmplantasyon, İnflamasyon, Biocompatible materials, Nickel-titanium alloys, Cytokines, Titanium, Immunocytokines, Implantation, Inflammation
  7. Yıl: 2023
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi-Cerrahpaşa
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Fizyoloji Ana Bilim Dalı
  12. Bilim Dalı: Fizyoloji Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Titanyum (Ti), klinik olarak birçok avantaja (biyouyumluluk, yüksek mukavemet, dayanıklılık) sahip olması nedeniyle implantasyon operasyonları için önemli bir yere sahiptir. Çalışmamızda Ti ve Titanyum-500 (Ti-500) biyomateryallerin spinal implantasyon sonrası akut dönemde, pro ve anti-inflamatuar sitokin mekanizmalarını nasıl etkilediğini, bununla birlikte bu iki biyomateryalin klinik olarak avantaj ve dezavantajlarını göstemeyi planladık. Araştırmamızda, erkek Wistar-albino soyundan sıçanlar üzerinde spinal bölgeye Ti ve Ti-500 implantlar yerleştirdik. Toplamda 21 adet erkek sıçan kullanıldı. Kontrol (K) (n=7), Ti (Ti) (n=7) ve Ti-500 (Ti 500) (n=7) gruplarına ayrıldı. Biyomateryaller, sıçanların L4 ve L5 arasına (10 mm çapında, 3 mm kalınlığında) implante edildi. 3., 7. ve 14. günlerde periferik kan örnekleri alındı ve IL-1ß, IL-4, IL-6, IL-10, TNF-α ve TGF-ß sitokinleri Multi Analiz yöntemleri (Luminex) kullanılarak analiz edildi. İmmün sistemin inflamasyona yanıtını değerlendirmek için implantasyon sonrası IL-1ß, IL-4, IL-6, IL-10, TNF-α ve TGF-ß sitokin seviyelerini karşılaştırmalı olarak analiz ettik. 3.günde K ile kıyaslandığında, IL-4 Ti grubunda, TGF- ß ise Ti500 gruplarında ise K grubuna kıyasla Ti500 gruplarında çok anlamlı bir düzeyde artış (p <0.001) göstermiştir. 7.günde K ile kıyaslandığında IL-4- ve TGF-ß hem Ti hem Ti500 grubunda çok anlamlı bir artış (p <0.001): IL-10 ise Ti500'de çok anlamlı (p <0.001) bir düşüş göstermiştir. 14.günde IL-4 Ti500 grubunda çok anlamlı artış (p <0.001) gösterirken, IL-10 ve TGF-ß çok anlamlı düşüş (p <0.001) göstermiştir. Sonuçları değerlendirdiğimizde Ti500 grubunun implantasyon sonrası anti-inflamatuar sitokin uyarısını arttırarak inflamasyonu regüle ettiği ve pro-inflamatuar sitokinleri suprese ettiği bulunmuştur. İnflamasyon sürecinin kontrol altına alınması, komplikasyonların engellenebilmesi, iyileşme sürecinin Ti'ye göre daha hızlı olabilmesi açısından Ti500 implant materyalinin daha avantajlı olduğu akut dönem çalışmamızda net olarak ortaya konmuştur.

Özet (Çeviri)

Titanium (Ti) has an important place for implantation operations because it has many clinical advantages (biocompatibility, high strength, durability). In our study, we planned to show how Ti and Ti500 biomaterials affect pro- and anti-inflammatory cytokine mechanisms in the acute period after spinal implantation, as well as the clinical advantages and disadvantages of these two biomaterials. In our research, we placed Ti and Titanium-500 (Ti-500) implants in the spinal region on male Wistar-albino rats. A total of 21 male Wistar-albino rats were used. They were divided into control (K) (n=7), Titanium (Ti) (n=7) and Titanium-500 (Ti 500) (n=7) groups. Biomaterials were implanted between L4 and L5 (10 mm in diameter, 3 mm in thickness) of rats. Peripheral blood samples were taken on the 3rd, 7th and 14th days and the cytokines IL-1ß, IL-4, IL-6, IL-10, TNF-α and TGF-ß were analyzed using Multi Analysis methods (Luminex). To evaluate the immune system's response to inflammation, we comparatively analyzed the cytokine levels of IL-1ß, IL-4, IL-6, IL-10, TNF-α and TGF-ß after implantation. When compared with K on the 3rd day, IL-4 in Ti group and TGF-ß in Ti500 groups showed a very significant increase (p <0.001) in Ti500 groups compared to K group.Compared with K at day 7, IL-4- and TGF-ß showed a very significant increase (p < 0.001) in both Ti and Ti500 groups: IL-10 showed a very significant (p <0.001) decrease in Ti500. On day 14, IL-4 showed a very significant increase (p <0.001) in the Ti500 group, while IL-10 and TGF-ß showed a very significant decrease (p <0.001). When we evaluated the results, it was found that the Ti500 group regulated inflammation and suppressed pro-inflammatory cytokines by increasing the anti-inflammatory cytokine stimulation after implantation. In our acute period study, it has been clearly demonstrated that the Ti500 implant material is more advantageous in terms of controlling the inflammation process, preventing complications, and speeding up the healing process compared to Ti.

Benzer Tezler

  1. Farklı dental implant materyallerinde termal siklusun yüzey özellikleri ve iyon salınımına etkisi

    Effect of thermal cycling on surface characteristics and ion release in different dental implant materials

    EFE DENİZ COŞGUNER

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2026

    Diş HekimliğiMarmara Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    DOÇ. DR. ONUR ATALI

  2. Ti-Base restorasyonlarda kullanılan materyallerin diş eti hücrelerine bağlantılarının in-vitro değerlendirilmesi

    The in-vitro evaluation of the adhesion of gingival cells to materials used for Ti-Base restorations

    DORUK ALTIOK

    Doktora

    Türkçe

    Türkçe

    2025

    Diş HekimliğiBaşkent Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. SELİM ERKUT

    DR. ÖĞR. ÜYESİ PELİN KILIÇ

  3. Tam dişsiz üst çenede all-on-4 protezlerde kullanılan farklı altyapı materyallerinin travmatik kuvvetler altında oluşan stresinin sonlu elemanlar stres analizi ile değerlendirilmesi

    Evaluation of stress generated under traumatic forces in different substructure materials used in all-on-4 prostheses in the fully edentulous upper jaw using finite element analysis

    SEVGİ ÇETİNTAŞ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2025

    Diş HekimliğiEskişehir Osmangazi Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. SEÇİL ÖZKAN ATA

  4. CAD/CAM sistemi ile üretilen hibrit abutment destekli anterior restorasyonda kemik rezorpsiyon riskinin ve stres dağılımının sonlu elamanlar analizi ile incelenmesi

    Investigation of bone resorption risk and stress distribution in hybrid abutment supported anterior restoration produced with CAD/CAM system by finite element analysis

    CİHAN AKDOĞAN

    Doktora

    Türkçe

    Türkçe

    2024

    Diş HekimliğiAtatürk Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. HATİCE ÖZDEMİR

  5. Farklı abutment materyallerinin siklik yükleme sonucundaki vertikal uyumunun ve tork kaybının İn Vitro olarak değerlendirilmesi

    In Vitro evaluation of vertical compliance and torque loss of different abutment materials after cyclic loading

    ULVİYE SEDA GÜL YÜCE

    Doktora

    Türkçe

    Türkçe

    2024

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. TAYFUN BİLGİN