Kısa segment posterior segmental enstrümantasyonda kırık seviyesine uygulanan vida boyutunun biyomekanik etkisi
The biomechanical effect of screw size applied to the level of fracture in posterior segmental instrumentation
- Tez No: 843209
- Danışmanlar: DOÇ. DR. AHMET KARAKAŞLI
- Tez Türü: Tıpta Uzmanlık
- Konular: Ortopedi ve Travmatoloji, Orthopedics and Traumatology
- Anahtar Kelimeler: Biyomekanik, Biyomekanik analiz, Kemik ve kemikler, Kemik vidaları, Kırıklar-kemik, Omurga, Spinal kırıklar, Biomechanics, Biomechanical analysis, Bone and bones, Bone screws, Fractures-bone, Spine, Spinal fractures
- Yıl: 2023
- Dil: Türkçe
- Üniversite: Dokuz Eylül Üniversitesi
- Enstitü: Tıp Fakültesi
- Ana Bilim Dalı: Ortopedi ve Travmatoloji Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Giriş ve Amaç: Torakolomber bileşke kırıklarının kısa segment posterior segmental entrumentasyon ile tedavisinde kırık seviyesine uygulanan pedikül vidası biyomekanik ve klinik olarak stabiliteye önemli katkı sağlamaktadır. Kırık seviyesine uygulanan ideal vida boyutu hakkında ise literatürde net bir bilgi bulunmamaktadır. Bu çalışmanın amacı torakolomber vertebra kırıklarının cerrahi tedavisinde uygulanan kısa segment posterior enstrumantasyonda kırık vertebraya yerleştirilen pedikül vida boyutunun biyomekanik açıdan stabiliteye etkisini değerlendirmektir. Materyal ve Method: Çalışmada 21 adet taze koyun kadavra torakolomber omurgası kullanılmıştır. 21 kadavra rastgele seçilerek 3 gruba ayrıldı. L1 seviyesinde düşen kütle modeli ile deneysel instabil torakolomber kırık modeli oluşturulmuştur. Her numune T12-L2 seviyesi korunacak şekilde proksimalden ve distalden alçı ile potlanmıştır. 1. Grupta intermediate vidasız, 2. Grupta vertebra korpus uzunluğunun %50'sini geçmeyecek uzunlukta (20mm) intermediate vida, 3. Grupta ise vertebra korpus uzunluğunun %70'ini geçecek uzunlukta (30mm) intermediate vidalı kısa segment posterior segmental enstrumentasyon uygulanmıştır. Fikse edilen her bir numuneye elektromekanik aküatör ile (10 kN AG-X; Shimadzu, Kyoto, Japan) aksiyel nötral yüklenme, fleksiyon/ekstansiyon, lateral bending ve aksiyel rotasyon testi uygulanmış ve uzama miktarları kaydedilmiştir. Verilerin dağılımını değerlendirmek için Shapiro-Wilk testi; bağımsız gruplarda Kruskal Wallis testi ve Mann Whitney U testi; bağımlı gruplarda Wilcoxon İşaretli Sıra testi kullanılmıştır. Bulgular: Stabil olmayan patlama kırıklarından sonra L1'e vida yerleştirilmesinin, sistemin stabilitesini geleneksel kısa segment posterior enstrumantasyon tekniğine kıyasla aksiyel yüklenme, fleksiyon/ekstansiyon, lateral bending ve aksiyel rotasyon yönlerinde anlamlı derecede iyileştirdiği görüldü. L1'e eklenen kısa veya uzun pedikül vidasının kısa segment posterior enstrumante iki sistem arasında ise aksiyel yüklenme, fleksiyon/ekstansiyon, lateral bending ve aksiyel rotasyon yönlerinde ise istatistiksel açıdan anlamlı derecede bir fark gözlenmedi (G1<G2=G3). Grup içi sağ ve sol lateral bending hareketlerinde farklılıklar olmasına rağmen istatistiksel anlamlı bir fark yoktur. Sonuç: Koyun kadavra modelinde kırık seviyesine vida eklenmesi, kısa segment posterior segmental enstrumantasyonda biyomekanik açıdan stabiliteye katkıda bulunmaktadır. Kırık seviyesine uygulanan pedikül vida uzunluğunun vertebra corpusunun %50 sinden daha az kısmına ilerlemesi ile %70'inden daha derine ilerlemesi benzer biyomekanik stabilite sağlamaktadır. Daha uzun boyutta bir pedikül vidasının kırık fragmanlarını deplese etme riski mevcut olup kırık fragmanları içinde biyolojik olmayan bir metaryal iyileşmeyi olumsuz yönde etkileyecektir.
Özet (Çeviri)
Introduction and Purpose: In the treatment of thoracolumbar junction fractures using short segment posterior segmental instrumentation, the pedicle screw applied to the fracture level significantly enhances biomechanical and clinical stability. There is no clear information in the literature about the ideal screw size applied to the fracture level. The aim of this study is to evaluate the effect of the pedicle screw size placed on the fractured vertebra on biomechanical stability in short segment posterior instrumentation applied in the surgical treatment of thoracolumbar vertebral fractures. Material and Method: 21 fresh sheep cadaver thoracolumbar spines were used in the study. 21 cadavers were randomly selected and divided into 3 groups. An experimental unstable thoracolumbar fracture model was created with the falling mass model at the L1 level. Each sample was cast proximally and distally to preserve the T12-L2 level. Short segment posterior segmental instrumentation was applied in 3 different ways. Separate groups comprised the study: in the 1st group, without intermediate screws, in the 2nd group, with an intermediate screw of a length not exceeding 50% of the vertebral body length (20 mm), and in the 3rd group, with an intermediate screw of a length not exceeding 70% of the vertebral body length (30 mm). Axial neutral loading, flexion/extension, lateral bending and axial rotation tests were applied to each fixed sample with an electromechanical actuator (10 kN AG-X; Shimadzu, Kyoto, Japan) and the results were recorded. Shapiro-Wilk test to evaluate the distribution of data; Kruskal Wallis test and Mann Whitney U test in independent groups and Wilcoxon Signed Rank test in dependent groups was used. Results: It was observed that screw placement in L1 after unstable burst fractures significantly improved the stability of the system in axial loading, flexion/extension, lateral bending and axial rotation directions compared to the traditional short segment posterior instrumentation technique. No statistically significant difference was observed between the two systems in the axial load, flexion/extension, lateral bending and axial rotation directions of the short or long pedicle screw added to L1 and the short segment posterior instrument (G1<G2=G3). Although there are differences in right and left lateral bending movements within the group, there is no statistically significant difference. Conclusion: Adding screws to the fracture level in the sheep cadaver model contributes to biomechanical stability in short segment posterior segmental instrumentation. Proceeding the length of the pedicle screw applied to the fracture level into shorter than 50% or longer than 70% of vertebral corpus provides similar biomechanical stability. Also, there is a risk that a longer pedicle screw will displace the fracture fragments and a non-biological material within the fracture fragments will negatively affect healing.
Benzer Tezler
- Kuyruk modelleri ve analizi üzerine bir uygulama
Başlık çevirisi yok
DİDEM ÖZPULAT
Yüksek Lisans
Türkçe
1985
Ege ÜniversitesiBilgisayar Bilimleri ve Mühendisliği Ana Bilim Dalı
Yükleniyor...
- Adolesan intihar girişimlerinin psiko-sosyal nedenleriyle ilgili araştırma
Başlık çevirisi yok
NAZMİYE YÜKSEL
- Çocuklarda akut stres hiperglisemisinde hormonal değişikliklerin ve kısa süreli prognozun incelenmesi
Başlık çevirisi yok
AYGÜN DİNDAR
Tıpta Uzmanlık
Türkçe
1987
İstanbul ÜniversitesiÇocuk Sağlığı ve Hastalıkları Hemşireliği Ana Bilim Dalı
Yükleniyor...
- Manisa yöresinde domateste anlaşmalı tarım ve karşılaşılan sorunlar
Başlık çevirisi yok
OSMAN MURAT KOÇTÜRK