Üç farklı elektronik apeks bulucunun kanal boyu ölçme etkinliğinin çeşitli yıkama solüsyonları varlığında kıyaslanması: Ex Vivo bir çalışma
Comparison of the canal length measurement efficiency of threedifferent electronic apex locators in the presence of various i̇rrigation solutions
- Tez No: 863821
- Danışmanlar: DR. ÖĞR. ÜYESİ MUZAFFER EMİR DİNÇOL
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2024
- Dil: Türkçe
- Üniversite: İstanbul Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Endodonti Ana Bilim Dalı
- Bilim Dalı: Endodonti Bilim Dalı
- Sayfa Sayısı: 113
Özet
Bu tez çalışmasının amacı, çekilmiş dişlerde üç adet farklı elektronik apeks bulucun kök kanalı içerisinde farklı yıkama solüsyonları varlığında ölçüm doğruluğunun değerlendirilmesi ve kıyaslanmasıdır. 55 adet çekilmiş insan üst orta kesici dişler mine-sement seviyesine kadar aljinata gömülerek Root Zx Mini (RTZX), Propex II (PRX) ve Adaptive Apex Locater (OPTCL) elektronik apeks bulucuları test edilmiştir. Kullanılan dişlerin gerçek kök kanalı uzunluğu (GKKU) stereomikroskop altında 15 numaralı K tipi eğenin ucunun apikal foramen noktasında görülünceye kadar iletletilip eğenin lastik ronteli ve ucu arasındaki mesafenin 0,01 mm hassasiyetteki dijital kumpas ile ölçülmesiyle belirlenmiştir. Dişler rastgele beş farklı gruba ayrılmıştır ve her bir grup için farklı yıkama solüsyonları varlığında elektronik apeks bulucu ölçümleri 15 numaralı k tipi eğe ile gerçekleştirilmiştir. Birinci grup hariç kök kanalları kurulanmamıştır. Elektronik apeks bulucu ölçümlerinin gerçekleştirildiği yıkama solüsyonları serum fizyolojik, sodyum hipoklorit (NaOCl), EDTA ve klorheksidin olarak belirlenmiştir. Ölçümler istatistiksel olarak değerlendirilmiştir. Gerçek kök kanalı uzunluğu ile elektronik apeks bulucular ile yapılan ölçümler arasında istatistiksel olarak anlamlı bir fark tespit edilememiştir (p>0.05). Cihazlar arasında ±0.5 mm aralığında, sapma görülme oranlarının sıklığı arasında istatistiksel olarak anlamlı bir farklılık bulunamamıştır (p:0.066; p>0.05). RTZX cihazının ölçümlerinin %83.6'sı, PRX cihazının ölçümlerinin %69.1'i ve OPTCL cihazının ölçümlerinin ise %74.5'i ±0.5 mm aralığındadır. Propex II'nin diğer cihazlara göre kök kanalında %5,25'lik NaOCl solüsyonu varlığında gerçek kök kanalı uzunluğundan ±0,5 mm aralığında istatistiksel olarak anlamlı derecede daha fazla sapma gösterdiği tespit edilmiştir (p:0.001; p
Özet (Çeviri)
The aim of this study is to evaluate and compare the measurement accuracy of three different electronic apex locators in extracted teeth in the presence of different irrigation solutions in the root canal. Fifty-five extracted human maxillar central incisors were embedded in alginate to the enamel-cementum level and the Root Zx Mini (RTZX), Propex II (PRX) and Adaptive Apex Locater (OPTCL) electronic apex locators were tested. The actual canal length was determined by introducing a size #15 k-type file into the canal until its tip became visible at the major apical foramen under a microscope at x10 magnification. A rubber stop was then carefully adjusted to the reference level and the distance between the rubber stop and the file tip was measured with a digital calliper to the nearest 0.01 mm and recorded. The teeth were randomly divided into five different groups and for each group, electronic apex locator measurements were performed with a #15 k-type file in the presence of different irrigation solutions. Root canals were not dried except for the first group. The irrigation solutions in which the electronic apex locator measurements were performed were saline, sodium hypochlorite (NaOCl), EDTA and chlorhexidine (CHX). The measurements were evaluated statistically. There was no statistically significant difference between the actual root canal length and the measurements made with the electronic apex locators (p>0.05). There was no statistically significant difference in the frequency of deviation within ±0.5 mm between the devices (p:0.066; p>0.05). 83.6% of the RTZX, 69.1% of the PRX and 74.5% of the OPTCL measurements were within ±0.5 mm. Propex II showed a statistically significant greater deviation from the true root canal length in the range of ±0.5 mm in the presence of 5.25% NaOCl solution in the root canal than the other devices (p:0.001; p
Benzer Tezler
- Kısmi türevli diferansiyel denklemlerin yeni Jakobi eliptik fonksiyon çözümleri
New Jacobi elliptic function solutions of partial differential equations
NAİL TURHAN
Yüksek Lisans
Türkçe
2015
MatematikBozok ÜniversitesiMatematik Ana Bilim Dalı
YRD. DOÇ. DR. YUSUF PANDIR
- İşletmelerde finansal başarısızlık tahminlemesi ve Borsa İstanbul'da faaliyet gösteren gıda şirketlerinde uygulama
Financial distress forecasting in businesses and application in food companies operating in stock exchange Istanbul
KEREM URAL
- Besinsel liflere bağlı biyoaktif maddelerin antioksidan kapasitesi ve rejenerasyon davranışının quencher metoduyla belirlenmesi
Determination of antioxidant capacity and regeneration behaviour of bioactive materials bound to dietary fibers with quencher procedure
ECEM EVRİM ÇELİK
Yüksek Lisans
Türkçe
2013
Gıda MühendisliğiHacettepe ÜniversitesiGıda Mühendisliği Ana Bilim Dalı
PROF. DR. VURAL GÖKMEN
- Genç bayan ve erkeklerde göz çevresi antropometrik ölçümlerinin karşılaştırılmalı olarak incelenmesi
A comparative study of measurements of the soft orbits in young women and men
MELTEM AÇAR GÜDEK
- Osmanlı İmparatorluğu'nda devlet, iktidar ve meşruiyet
State, power and legitimacy in the Ottoman Empire
ATİLLA ALTUN
Yüksek Lisans
Türkçe
2014
SosyolojiKırıkkale ÜniversitesiSosyoloji Ana Bilim Dalı
DOÇ. DR. İBRAHİM MAZMAN