Hava hızı, sıcaklığı ve neminin yoğuşma olayına etkisinin farklı soğutucu akışkanlar için deneysel ve sayısal incelenmesi

Experimental and numerical investigation of the effect of air velocity, temperature and humidity on condensation for different refrigerants

  1. Tez No: 914746
  2. Yazar: HAYATİ TÖRE
  3. Danışmanlar: PROF. DR. ALİ KILIÇARSLAN
  4. Tez Türü: Doktora
  5. Konular: Makine Mühendisliği, Mühendislik Bilimleri, Mechanical Engineering, Engineering Sciences
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2024
  8. Dil: Türkçe
  9. Üniversite: Hitit Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 123

Özet

Bu tez çalışmasında, termodinamik analiz, termal kamera görüntüleme ve hesaplamalı akışkanlar dinamiği (HAD) analiz yöntemleri kullanılarak, yoğuşturucu dış tarafından geçen havanın farklı hızları, sıcaklıkları ve bağıl nem değerlerinin, içerisinden R134a, R1234yf, R507a ve R32 gibi güncel soğutucu akışkanların geçtiği, kanatçıklı borulu bir yoğuşturucuda meydana gelen yoğuşma olayı üzerindeki etkileri araştırılmıştır. Yoğuşturucu yüzeyindeki sıcaklık görüntülerini elde etmek amacıyla termal kamera izleme yöntemi kullanılmıştır. Ayrıca, bilgisayar ortamında üç boyutlu geometrisi oluşturulmuş yoğuşturucunun içerisindeki ve dış tarafındaki sıcaklık ve akış dağılımları sürekli rejim şartlarında HAD analizi yapılarak çözümlenmiştir. Tez çalışmasından elde edilen sonuçlara göre; termodinamik analiz ve HAD analizinden elde edilen sonuçlar arasındaki en yüksek sapma miktarının bağıl nem deneyi için %17.34 ile R134a akışkanı için soğutucu akışkan tarafı ortalama taşınım ısı transfer katsayısında olduğu tespit edilmiş, ayrıca, termal kamera izleme yönteminden elde edilen sıcaklık görüntüleri ve HAD analizinden elde edilen konturlerin de iyi bir uyum içerisinde olduğu görülmüştür. Kullanılan soğutucu akışkanlar için, hava hızının ortalama olarak %85 oranında artmasıyla birlikte, ortalama olarak, yoğuşturucu kapasitesinin %10.31 ve soğutucu akışkan tarafı taşınım ısı transfer katsayısının %7.41 oranında arttığı, aynı zamanda kuruluk derecesinin ise %32.56 oranında azalarak, yoğuşma olayının giderek iyileştiği tespit edilmiştir. Hava sıcaklığının %43.75 oranında artmasıyla, yoğuşturucu kapasitesi ve soğutucu akışkan taşınım ısı transfer katsayısında ortalama olarak sırasıyla, %15.06 ve %8.23 azalma olduğu, kuruluk derecesinde ise %17.08'lik artma olduğu tespit edilerek, yoğuşma olayının olumsuz yönde etkilendiği belirlenmiştir. Ayrıca, bağıl nemin %108.33 oranında artması sonucunda, yoğuşturucu kapasitesi ve soğutucu akışkan tarafı taşınım ısı transfer katsayısında ortalama olarak sırasıyla, %11.69 ve %7.08 azalma olduğu, kuruluk derecesinde ise %21.68'lik artma olduğu tespit edilmiştir.

Özet (Çeviri)

In this thesis, it was investigated that the effects of different velocities, temperatures and relative humidities of the air passing through the outside surface of the condenser on the condensation phenomena occurring in a finned tube condenser inside which the refrigerants including R134a, R1234yf, R507a and R32 flow by means of the thermodynamic analysis, thermal camera monitoring and computational fluid dynamics (CFD) analysis methods. Thermal camera monitoring method was used to obtain temperature images on the condenser surface. In addition, the temperature and flow distributions inside and outside the condenser, whose three-dimensional geometry was created in the computer environment, were analyzed by CFD analysis under steady-state conditions. According to the results obtained from the thesis study, the highest deviation between the results obtained from thermodynamic analysis and CFD analysis was found to be in the refrigerant side convection heat transfer coefficient of R134a with 17.34% for the relative humidity experiment, and it was also observed that the temperature images obtained from the thermal camera monitoring method and the contours obtained from CFD analysis were in good agreement. For the refrigerants used, it was found that with an average increase of 85% in air velocity, the condenser capacity increased by 10.31% and the refrigerant side convection heat transfer coefficient increased by 7.41%, while the degree of vapor quality decreased by 32.56% and the condensation phenomena gradually improved. With an increase of 43.75% in air temperature, the condenser capacity and refrigerant side convection heat transfer coefficient decreased by 15.06% and 8.23%, respectively, and the vapor quality increased by 17.08%, negatively affecting the condensation phenomena. In addition, as a result of 108.33% increase in relative humidity, it was determined that there was an average decrease of 11.69% and 7.08% in condenser capacity and refrigerant side concective heat transfer coefficient, respectively, and an increase of 21.68% in the vapor quality.

Benzer Tezler

  1. Kömürlerin kendiliğnden yanmasının teorik ve deneysel incelenmesi

    Theoretical and experimental investigations of spontonequs combustion of coals

    FEHMİ AKGÜN

    Doktora

    Türkçe

    Türkçe

    1994

    Makine Mühendisliğiİstanbul Teknik Üniversitesi

    PROF.DR. AHMET ARISOY

  2. Çukurova Bölgesi'nde iklim faktörlerinin traktör sürücülerine etkileri ve sürücü çalışma ortamlarının değerlendirilmesi üzerine bir araştırma

    A research on the evaluation of operators working places and the effects of the climatic conditions on the operators in Çukurova Region

    ALİ AYBEK

    Doktora

    Türkçe

    Türkçe

    1996

    ZiraatÇukurova Üniversitesi

    PROF.DR. ALAETTİN SABANCI

  3. Havanın soğutulması ve neminin alınması amacıyla kullanılan kanatlı borulu ısı değiştiricilerin kuramsal ve deneysel incelenmesi

    Theoretical and experimental analysis of finned tube wet coils

    ALTAY ARBAK

    Yüksek Lisans

    Türkçe

    Türkçe

    2014

    Makine Mühendisliğiİstanbul Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. ALİ TANER DERBENTLİ

  4. Bir iklimlendirme odasının bulanık mantık yöntemi ile kontrolü

    Fuzzy control of a HVAC system

    HASAN ERDAL

    Doktora

    Türkçe

    Türkçe

    1998

    Elektrik ve Elektronik MühendisliğiMarmara Üniversitesi

    Elektrik Eğitimi Ana Bilim Dalı

    PROF. DR. BURHANETTİN CAN

  5. İklimlendirme sistemlerinin yapı içi hava niteliği üzerindeki olumsuz etkileri

    The negative effects of air conditioning systems on indoor air quality

    AYGÜL CEYLAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2011

    MimarlıkYıldız Teknik Üniversitesi

    Mimarlık Ana Bilim Dalı

    PROF. DR. AYŞE BALANLI