Piston hareketli aktif manyetik rejeneratif soğutucu tasarımı ve performans optimizasyonu

Reciprocating motion active magnetic regenerative refrigerator design and performance optimization

  1. Tez No: 928687
  2. Yazar: ARDA ZAİM
  3. Danışmanlar: PROF. DR. HAYDAR ARAS
  4. Tez Türü: Doktora
  5. Konular: Enerji, Makine Mühendisliği, Energy, Mechanical Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2025
  8. Dil: Türkçe
  9. Üniversite: Eskişehir Osmangazi Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Enerji Termodinamik Bilim Dalı
  13. Sayfa Sayısı: 124

Özet

Manyetik soğutma, temeli manyetokalorik etkiye dayanan yeni bir soğutma teknolojisidir. Manyetokalorik etkinin fiziksel orijini ise malzeme üzerine uygulanan manyetik alanın, malzemenin entropisinde değişiklik meydana getirmesidir. Manyetik soğutma sistemleri; manyetokalorik etki gösteren bir malzemenin manyetik alan kaynağı etkisinde meydana gelen entropi değişiminden kaynaklı ısınma ve soğuma etkisini bir ısı transfer akışkanı kullanarak dış ortamla ısı alışverişi sağlaması prensibiyle çalışmaktadır. Bu tez çalışmasında detaylı literatür araştırması sonucunda oda sıcaklığında çalışabilen, manyetokalorik malzeme olarak rejeneratöründe Gd ve La0.75Ba0.25MnO3 perovskit manganit bileşiği kullanabilen, özgün ve ileri teknoloji prototip piston hareketli aktif manyetik rejeneratif soğutucu tasarlanmış ve imal edilmiştir. Manyetik alan kaynağı ve hareket mekanizması, ısı transfer akışkanı ve hareket mekanizması, rejeneratör ve rejeneretörde yer alan manyetokalorik malzemeler gibi temel bileşenler literatürdeki çalışmalarla karşılaştırılmış ve irdelenmiştir. Prototip manyetik soğutucuyla farklı koşullarda basınç düşüşü, sıcaklık farkı, soğutma gücü ve soğutma tesir katsayılarının belirlenmesi için çeşitli deneysel çalışmalar gerçekleştirilmiş ve optimum parametreler belirlenmiştir. V ̇=0.042 – 4.53 l/h aralığında rejeneratörde ∆P ölçümü gerçekleştirilmiştir. Boş kartuşla V ̇=0.042 l/h durumunda ∆P= 0.020 bar, dolu kartuşla ∆P= 0.029 bar olarak belirlenmiştir. Yüksüz durumda gerçekleştirilen ∆T ölçümlerinde optimum parametreler olarak belirlenen φ=5, V_man 0.10 m/s, V ̇=2.5 l/h durumunda elde edilen maksimum sıcaklık farkları Gd rejeneratörde ∆T=2.197 K ve La0.75Ba0.25MnO3 rejeneratörde ∆T=1.472 K olarak tespit edilmiştir. V ̇=2.5 l/h ve ∆T=1 K gerçekleştirilen soğutma gücü ölçümlerinde Gd rejeneratörde Q_L=3.5 W, La0.75Ba0.25MnO3 rejeneratörde Q_L=1.75 W olarak belirlenmiştir. V ̇=3.0 l/h ve Q_L=5.91 W durumunda Gd rejeneratörde elde edilen maksimum COP=1.32'dir. La0.75Ba0.25MnO3 rejeneratörde ise V ̇=3.0 l/h ve Q_L=4.68 W durumunda maksimum COP= 0.89'dur.

Özet (Çeviri)

Magnetic refrigeration is a new technology based on the magnetocaloric effect. The physical origin of the magnetocaloric effect is that the magnetic field applied to the material causes a change in the entropy of the material. Magnetic refrigeration systems work on the principle that a material that exhibits a magnetocaloric effect provides heat exchange with the external environment using a heat transfer fluid, which provides heating and cooling effects due to the entropy change that occurs under the influence of a magnetic field source. In this thesis study, as a result of detailed literature research, an original and high-tech prototype piston-moving active magnetic regenerative refrigerator, which can operate at room temperature and can use Gd and La0.75Ba0.25MnO3 perovskite manganite compounds as magnetocaloric materials in its regenerator, has been designed and manufactured. Basic components such as magnetic field source and movement mechanism, heat transfer fluid and movement mechanism, regenerator and magnetocaloric materials in the regenerator have been compared with the studies in the literature and examined. Various experimental studies have been carried out to determine the pressure drop, temperature difference, cooling power and coefficient of performance under different conditions with the prototype magnetic refrigerator and optimum parameters have been determined. ∆P measurement was carried out in the regenerator in the range of V ̇=0.042 – 4.53 l/h. With an empty cartridge, ∆P= 0.020 bar at V ̇ ̇=0.042 l/h, and ∆P= 0.029 bar with a full cartridge. In the ∆T measurements carried out under no-load condition, the optimum parameters determined as φ=5, V_man=0.10 m/s, V ̇=2.5 l/h, the maximum temperature differences obtained were ∆T =2.197 K in the Gd regenerator and ∆T =1.472 K in the La0.75Ba0.25MnO3 regenerator. V ̇=2.5 l/h and ∆T =1 K the cooling power measurements were determined as Q_L=3.5 W in Gd regenerator and Q_L=1.75 W in La0.75Ba0.25MnO3 regenerator. The maximum COP=1.32 obtained in Gd regenerator for V ̇=3.0 l/h and Q_L=5.91 W. The maximum COP=0.89 in La0.75Ba0.25MnO3 regenerator for V ̇=3.0 l/h and Q_L=4.68 W.

Benzer Tezler

  1. Manyeto-reolojik sıvılı yarı-aktif bir sönümleyici tasarımı ve analizi

    Design and analysis of a semi-active damper with mangnetorheological fluid

    ZEKERİYA PARLAK

    Doktora

    Türkçe

    Türkçe

    2010

    Makine MühendisliğiSakarya Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. İSMAİL ÇALLI

  2. Sedimentary records of active faulting in Kumburgaz basin, sea of Marmara

    Aktif faylanmanın Kumburgaz havzasındaki sedimanter kayıtları, Marmara denizi

    NURETTİN YAKUPOĞLU

    Yüksek Lisans

    İngilizce

    İngilizce

    2017

    Jeoloji Mühendisliğiİstanbul Teknik Üniversitesi

    Jeoloji Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. GÜLSEN UÇARKUŞ

  3. Klasik ve alternatif titreşim yutucuların incelenmesi

    Investigating the classical and alternative vibration absorbers

    RIDVAN DOĞRU

    Yüksek Lisans

    Türkçe

    Türkçe

    2015

    Makine Mühendisliğiİstanbul Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. KENAN YÜCE ŞANLITÜRK

  4. Numerical and experimental study of turbulent jet ignition method on wankel engine with passive pre-chamber

    Türbülanslı jet tutuşturma yönteminin wankel motorunda pasif ön yanma odası ile numerik ve deneysel çalışması

    HARUN DİLLİCE

    Yüksek Lisans

    İngilizce

    İngilizce

    2024

    Makine Mühendisliğiİstanbul Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    DOÇ. DR. OSMAN AKIN KUTLAR

  5. NACA0015 kanat profili üzerinde çift yarıklı koordineli jet aktüatör ile aktif akış kontrolünün deneysel ve sayısal incelenmesi

    Experimental and numerical investigation of active flow control by coordinately jet actuator with dual slot on NACA0015 airfoil

    FATİH SONKAYA

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    Havacılık Mühendisliğiİstanbul Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ SERTAÇ ÇADIRCI

    DR. ÖĞR. ÜYESİ DUYGU ERDEM