Geri Dön

Karaciğer fantomunda farklı hacimlerdeki taklit tümörlerin sintigrafik görüntülerinin değerlendirlmesi

Evaluation of scintigraphic images of simulated tumors with different volumes in a liver phantom

  1. Tez No: 966195
  2. Yazar: MURAT KOZANLILAR
  3. Danışmanlar: PROF. DR. MUSTAFA DEMİR
  4. Tez Türü: Yüksek Lisans
  5. Konular: Radyoloji ve Nükleer Tıp, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: ⁹⁹ᵐTc-MAA sintigrafisi, ⁹⁰Y radyoembolizasyon, ön-dozimetri, görüntü kalitesi, tümör dozu, ⁹⁹ᵐTc-MAA scintigraphy, ⁹⁰Y radioembolization, pre-dosimetry, image quality, tumor doses
  7. Yıl: 2025
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi-Cerrahpaşa
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Nükleer Tıp Ana Bilim Dalı
  12. Bilim Dalı: Sağlık Fiziği Bilim Dalı
  13. Sayfa Sayısı: 86

Özet

Amaç: Yitriyum-90 (⁹⁰Y) ile yapılan radyoembolizasyon ve doz öncesi değerlendirme amacıyla Teknesyum-99m makroagregat albümin (⁹⁹ᵐTc-MAA) kullanımı, rezeksiyon yapılamayan karaciğer tümörlerinin tedavisinde rutin olarak etkili yöntemlerdir. Bu çalışmada, tümör hacmindeki değişikliklerin ve tümörlerin birbirine yakınlıklarının sintigrafik görüntü kalitesi ve dozimetri üzerindeki etkisinin değerlendirilmesi ve bu etkilerin kontrast ve kontrast-gürültü oranı (CNR) parametreleri kullanılarak nesnel biçimde analiz edilmesi amaçlanmıştır. Gereç ve Yöntem: Bu deneysel çalışmada, çapları 1 cm, 2 cm, 3 cm ve 5 cm olan dört simüle tümör içeren özel tasarlanmış bir karaciğer fantomu kullanılmıştır. Tümörler ile çevresindeki karaciğer parankim dokusunu taklit eden bölgeler, ⁹⁹ᵐTc ile 4.88:1 oranında doldurulmuştur. Fantom, bir su tankı içinde hem planar hem de SPECT sintigrafi için standart klinik protokoller kullanılarak görüntülenmiştir. Görüntülerdeki lezyonların üzerine ilgi bölgeleri (ROI) çizilerek kontrast, CNR ve tümör dozları hesaplanmıştır. Bulgular: SPECT görüntülerinde tümör çapı arttıkça, mililitre başına düşen tümör/normal karaciğer oranı (T/N), kontrast, CNR ve tümör dozları da artmıştır. Çapı 1 cm olan lezyon için tümör dozu 6.9 Gy/ml, 5 cm olan için ise 13.43 Gy/ml olarak bulunmuştur. Benzer şekilde, plan görüntülemeden hesaplanan T/N oranları, kontrast ve CNR değerleri de tümör boyutu ile artmıştır; ancak tümör dozundaki artışın nispeten daha düşük olduğu gözlenmiştir. Tartışma ve Sonuç: Bu çalışmada, ⁹⁹ᵐTc-MAA ile yapılan karaciğer tümörü ön-dozimetri değerlendirmelerinde küçük ve çoklu tümörlerin varlığında ROI sayımlarının karşılıklı etkisi analiz edilmiştir. Daha büyük tümörlerin yakınında yer alan küçük tümörlerin (1–3 cm) büyük lezyonlardan kaynaklanan taşma (spillover) etkisinden etkilendiği, bunun da ROI sayımlarında yapay artışa ve dolayısıyla doz hesaplamalarında aşırı tahmine neden olduğu gözlenmiştir. Sonuç olarak, büyük lezyonların varlığı, 1–3 cm çapındaki daha küçük tümörlerin dozimetrik değerlendirmelerini etkileyebilir ve hatalı doz tahminlerine yol açabilir.

Özet (Çeviri)

Objective: Yttrium-90 (⁹⁰Y) radioembolization and the use of Technetium-99m macroaggregated albumin (⁹⁹ᵐTc-MAA) for pre-dosimetry are routinely effective methods in the treatment of unresectable liver tumors. This study aims to evaluate the impact of tumor volume variation and tumor proximity on scintigraphic image quality and dosimetry, and to objectively analyze these effects using contrast and contrast-to-noise ratio (CNR) parameters. Materials and Methods: In this experimental study, a specially designed liver phantom containing four simulated tumors with diameters of 1 cm, 2 cm, 3 cm, and 5 cm was used. The tumors and the surrounding liver parenchyma-mimicking areas were filled with ⁹⁹ᵐTc at a ratio of 4.88:1. The phantom was imaged in a water tank using standard clinical protocols for both planar and SPECT scintigraphy. Regions of interest (ROIs) were drawn over the lesions on the images to calculate contrast, CNR, and tumor doses. Results: In SPECT images, as tumor diameter increased, tumor-to-normal liver ratio (T/N) per milliliter, contrast, CNR, and tumor doses also increased. Tumor doses for 1 cm and 5 cm diameter lesions were found to be 6.9 Gy/ml and 13.43 Gy/ml, respectively. Similarly, T/N ratios, contrast, and CNR values calculated from planar imaging also increased with tumor size; however, the increase in tumor doses was found to be relatively lower. Discussion and Conclusion: This study analyzed the mutual effect of ROI counts in the presence of small and multiple tumors in ⁹⁹ᵐTc-MAA pre-dosimetry for liver tumors. It was observed that smaller tumors (1–3 cm) located near larger tumors were affected by spillover from the larger lesions, resulting in artificially elevated ROI counts and consequently overestimated dose calculations. In conclusion, the presence of larger lesions may influence dosimetric evaluations of smaller (1–3 cm) tumors, potentially leading to inaccurate dose assessments.

Benzer Tezler

  1. Karaciğer tümörlerinde Monte Carlo yöntemi ile radyonüklid dozimetri

    Radionuclide dosimetry with Monte Carlo method in liver tumors

    HANDAN TANYILDIZI KÖKKÜLÜNK

    Doktora

    Türkçe

    Türkçe

    2019

    Fizik ve Fizik Mühendisliğiİstanbul Üniversitesi

    Fizik Ana Bilim Dalı

    PROF. DR. BAKİ AKKUŞ

    PROF. DR. MUSTAFA DEMİR

  2. Cr-51 kullanılarak yapılan karaciğer sintigrafisi için üç kritik organa ilişkin dozların belirlenmesi ve mırd metodu ile karşılaştırılmalı değerlendirmesi

    Dose assesment of three critical organs for liver scintigraphy with using Cr-51 and the comparison with mird method

    ÖZLEM MARANCİ

    Yüksek Lisans

    Türkçe

    Türkçe

    2016

    Radyoloji ve Nükleer Tıpİstanbul Teknik Üniversitesi

    Nükleer Araştırmalar Ana Bilim Dalı

    PROF. DR. ASİYE BERİL TUĞRUL

  3. Characterization of temperature dependent dielectric properties of biological tissue phantoms using an open-ended coaxial probe

    Vücut dokularını taklit eden fantomların ısıya bağımlı dielektrik özelliklerinin aukp yardımıyla ölçülmei

    TUĞÇE TUTUK

    Yüksek Lisans

    İngilizce

    İngilizce

    2024

    Biyolojiİstanbul Teknik Üniversitesi

    Elektronik ve Haberleşme Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ CEMANUR AYDINALP

  4. İnsan eşdeğeri tümörlü bir karaciğer fantomunun sintigrafik görüntülerinde kısmi hacim etkisinin incelenmesi

    Investigation of partial volume effect on scintigraphic images of a human equivalent tumor liver phantom

    AYŞE DİLAVER AKAR

    Yüksek Lisans

    Türkçe

    Türkçe

    2025

    Sağlık Eğitimiİstanbul Aydın Üniversitesi

    Sağlık Bilimleri Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ EYLEM GÜLCE ÇOKER

    PROF. DR. MUSTAFA DEMİR

  5. Karaciğer için fizyolojik ve patolojik ultrasound görüntülemeye yönelik ISO17043 ve ISO 13485 kapsamında fantom tasarımı

    DESIGN OF A PHANTOM FOR PHYSIOLOGICAL AND PATHOLOGICAL ULTRASOUND IMAGING OF THE LIVER IN ACCORDANCE WITH ISO 17043 AND ISO 13485

    ERKAN KOLCU

    Yüksek Lisans

    Türkçe

    Türkçe

    2025

    BiyoteknolojiPamukkale Üniversitesi

    Biyomedikal Mühendisliği Ana Bilim Dalı

    PROF. DR. AHMET KOLUMAN