Geri Dön

YOĞUNLUK AYARLI ARK TEDAVİSİ (VMAT) PLANLARINDA DOZ ÇÖZÜNÜRLÜĞÜNÜN KALİTE KONTROL ÜZERİNE ETKİSİ

THE EFFECT OF DOSE RESOLUTION ON QUALITY ASSURANCE IN VOLUMETRİC MODULATED ARC THERAPY (VMAT) PLANS

  1. Tez No: 1005972
  2. Yazar: SEHER KARAMAZI
  3. Danışmanlar: DOÇ. DR. ELİF EBRU ERMİŞ, PROF. DR. LÜTFİYE ZÜMRE ARICAN ALICIKUŞ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Radyasyon Onkolojisi, Radiation Oncology
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: İzmir Tınaztepe Üniversitesi
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Sağlık Fiziği Ana Bilim Dalı
  12. Bilim Dalı: Sağlık Fiziği Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

İzmir Tınaztepe Üniversitesi Sağlık Fiziği Anabilim Dalı'nda yapılan bu tez çalışmasında, Yoğunluk Ayarlı Ark Tedavisi (VMAT) tekniği ile oluşturulan tedavi planlarında, doz çözünürlüğünün kalite kontrol (KK) süreçleri üzerindeki etkisinin, gama (γ) indeksi analizi kullanılarak karşılaştırılması ve değerlendirilmesi amaçlanmıştır. Bu çalışmada kullanılan 10 prostat kanseri hastasına ait tedavi planları 6 MV ve 10 MV enerjili X-ışın demetleri kullanılarak VMAT tekniği ile yapılmıştır. KK aşaması için referans fantomlar yine tedavi planlama sistemi (TPS) üzerinden her bir çözünürlük için ayrı ayrı oluşturulmuştur. Oluşturulan bu KK planlarının ölçümleri MatriXX Evolution Sistemi kullanılarak yapılmıştır. Ölçümler sonucunda elde edilen doz dağılımları, TPS ile oluşturulan referans doz dağılımları ile gama indeksi analizi kullanılarak karşılaştırılmıştır. %2 doz farkı ve 2 mm mesafe kriterleri göz önüne alınarak ölçümler değerlendirilmiştir. 7,62 mm çözünürlük için ortalama gama geçiş oranı %96,2 bulunmuştur. Bu değer 3,81 mm ve 1,0 mm çözünürlükleri için sırasıyla %99,1 ve %99,2 bulunmuştur. Değerlendirme kriterleri sebebiyle rektum ve mesane organlarına ait hacim verileri, kullanılan iki ışın alanı için maksimum alan genişliği, planlara ait normalizasyon yüzdeleri ve doğrusal hızlandırıcıdan çıkan çıkışın bir ölçüsü olan toplam LİNAK monitör ünitesi (MU) değerleri değerlendirilmiştir. Bu çalışmada elde edilen sonuçlar literatür ile uyumlu olup, doz hesaplama grid boyutu küçüldükçe doz dağılımı doğruluğu artmakta ve özellikle VMAT planlarında grid boyutu plan doğruluğunu etkileyen önemli bir parametre olarak ortaya çıkmaktadır. Ayrıca bu çalışma VMAT tekniği ile oluşturulan tedavi planlarında, farklı doz çözünürlüklerine bağlı olarak en optimal doz çözünürlüklerinin ne olması gerektiğinin belirlenmesini sağlayacaktır. Buna ek olarak KK süreçlerinin daha güvenilir ve etkin olarak sonuçlanmasına olanak verirken, hasta güvenliği ve tedavilerin kalitesi bakımından bir artış sağlamayı hedeflemektedir.

Özet (Çeviri)

This thesis study, conducted in the Department of Health Physics at İzmir Tınaztepe University, aimed to investigate and compare the effect of dose calculation grid resolution on quality assurance (QA) processes in treatment plans generated using the Volumetric Modulated Arc Therapy (VMAT) technique by means of gamma (γ) index analysis. In this study, VMAT treatment plans were created for 10 prostate cancer patients using 6 MV and 10 MV photon beams. For the QA procedure, reference phantoms were generated separately for each dose resolution within the treatment planning system (TPS). Quality assurance measurements were performed using the MatriXX Evolution system. The measured dose distributions were compared with the TPS-calculated reference dose distributions using gamma index analysis. The evaluation was performed using 2% dose difference and 2 mm distance-to-agreement criteria. The average gamma passing rate was found to be 96.2% for 7.62 mm resolution, while it was 99.1% and 99.2% for 3.81 mm and 1.0 mm resolutions, respectively. Additionally, rectum and bladder volume data, maximum field width for the two beam fields used, plan normalization percentages, and total monitor unit (MU) values were also evaluated. The results of this study are consistent with the literature, indicating that decreasing the dose calculation grid size improves dose distribution accuracy, and grid resolution is an important parameter affecting plan accuracy, especially in VMAT plans. Furthermore, this study contributes to determining the optimal dose resolution for VMAT treatment planning. In addition, improving QA reliability and efficiency may contribute to increased patient safety and overall treatment quality.

Benzer Tezler

  1. Meme kanseri radyoterapisinde hacimsel yoğunluk ayarlı ark tekniğiyle segment genişliklerinin tedavi kalitesine ve organ korunmasına etkisi

    The effect of segment widths on treatment quality and organ sparing with the volumetric modulated arc therapy technique in breast cancer radiotherapy

    ASİYE GÜROL

    Yüksek Lisans

    Türkçe

    Türkçe

    2026

    Radyasyon OnkolojisiAkdeniz Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    PROF. DR. NİNA TUNÇEL

  2. Radyoterapide volümetrik modüle edilmiş ark tedavisi planlarının optimizasyonunda“photon optimizer”algoritmasının“aperture shape controller”özelliğinin kullanımının etkileri

    The effects of using the aperture shape controller feature of photon optimizer algorithm in optimization of volumetric modulated ARC therapy plans in radiotherapy

    BAŞAK GÖKSEL

    Yüksek Lisans

    Türkçe

    Türkçe

    2020

    Fizik ve Fizik MühendisliğiDokuz Eylül Üniversitesi

    Medikal Fizik Ana Bilim Dalı

    PROF. DR. AYŞE NUR DEMİRAL

    DR. ÖĞR. ÜYESİ HAKAN EPİK

  3. Akut lenfoblastik lösemili (ALL) 5 yaşından küçük çocuk hastalarda kranial ışınlamalarda hedef hacmin (beyin dokusunun) aldığı dozun farklı tedavi planlama teknikleriyle karşılaştırılması

    Comparison of the target volume dose in cranial irradiation with different treatment planning techniques in children under 5 years of age with acute lymphoblastic leukemia

    CEREN GENÇALİOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    OnkolojiEge Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    PROF. DR. EMİNE SERRA KAMER

  4. Prostat kanseri radyoterapi tedavi planlarında hacimsel yoğunluk ayarlı ark tedavisi ve dinamik yoğunluk ayarlı radyoterapi tekniklerinin karşılaştırılması

    Comparison of volumetric modulated arc therapy and dynamic intensity modulated radiation therapy techniques in prostate cancer radiotherapy treatment plans

    YILMAZ BİLEK

    Yüksek Lisans

    Türkçe

    Türkçe

    2018

    OnkolojiAkdeniz Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    PROF. DR. AYLİN FİDAN KORCUM ŞAHİN

  5. Prostat kanserlerinin hacim modülasyonlu ark terapisinde filtreli ve filtresiz ışınların ve PTV boyutunun tedavi planına etkilerinin karşılaştırılması

    Comparison of the effects of filtered and unfiltered X-RAY beams and ptv size on the treatment plan in volumetric modulated ARC therapy of prostate cancers

    ÇAĞLAR NEBOL

    Yüksek Lisans

    Türkçe

    Türkçe

    2020

    Onkolojiİstanbul Üniversitesi

    Temel Onkoloji Ana Bilim Dalı

    PROF. DR. HATİCE BİLGE BECERİR