Geri Dön

Infrazygomatik krest bölgesine uygulanan minividaların farklı yükleme zamanlarına göre stabilitelerinin rezonans frekans analizi ile karşılaştırılması

Comparison of the stability of miniscrews applied to the infrazygomatic crest region according to different loading times using resonance frequency analysis

  1. Tez No: 1007241
  2. Yazar: HATİCE CANSU KIŞ
  3. Danışmanlar: PROF. DR. ALİ ALTUĞ BIÇAKÇI, DR. ÖĞR. ÜYESİ MELİKE ALTINIŞIK
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: Tokat Gaziosmanpaşa Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
  12. Bilim Dalı: Ortodonti Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Bu çalışmanın amacı, infrazygomatik krest (IZC) bölgesine yerleştirilen ortodontik minividaların farklı yükleme zamanlarının stabilite üzerindeki etkisini radyofrekans analizi (RFA) yöntemiyle değerlendirmektir. Gereç ve Yöntem: Bu çalışma, Tokat Gaziosmanpaşa Üniversitesi Diş Hekimliği Fakültesi Ortodonti Anabilim Dalı'nda yürütülen randomize, açık etiketli, split-mouth tasarımlı prospektif klinik bir araştırmadır. Çalışmaya toplam 21 gönüllü birey dâhil edilmiştir. Her bireyin sağ ve sol infrazygomatik krest bölgesine 2×12 mm paslanmaz çelik minivida (Morelli®) yerleştirilmiştir. Split-mouth tasarım gereği, taraflardan biri anında yükleme (yerleştirme anında kuvvet uygulanması), diğer taraf geç yükleme (kuvvetin 4 hafta sonra uygulanması) protokolüne randomize edilmiştir. Minivida stabilitesi, Osstell® cihazı ile rezonans frekans analizi kullanılarak Implant Stability Quotient (ISQ) değerleri üzerinden değerlendirilmiş; ölçümler yerleştirme sonrası, 1., 2. ve 3. aylarda kaydedilmiştir. İstatistiksel değerlendirmede tanımlayıcı istatistiklerin yanı sıra iki faktörlü tekrarlı ölçümler varyans analizi (protokol×zaman) uygulanmış; zaman noktalarına göre protokoller arası karşılaştırmalar eşleştirilmiş (bağımlı) örneklem t-testi ile yapılmış ve çoklu karşılaştırmalar için Bonferroni düzeltmesi kullanılmıştır. Anlamlılık düzeyi p<0,05 olarak kabul edilmiştir. Bulgular: Analiz sonucunda zaman ana etkisi anlamlı bulundu (p<0,001), protokol ana etkisi anlamlı değildi (p=0,257). Buna karşın protokol×zaman etkileşimi anlamlıydı (p=0,003). Ay bazında karşılaştırmalarda yalnızca 2. ölçümde geç protokol, anında protokole göre daha yüksek ISQ değerine sahipti (D−I=2,57; %95 GA: 1,35–3,79; p(Bonf)=0,001); diğer aylarda anlamlı fark saptanmadı (p>0,05). Yaş ve cinsiyet değişkenlerinin protokol ortalamaları üzerinde anlamlı etkisi izlenmedi (erkek katılımcı sayısının düşük olması nedeniyle cinsiyet analizi keşifsel olarak değerlendirildi). Sonuç: Anında ve geç yükleme protokolleri genel stabilite düzeyi açısından benzerdir. Protokoller arasındaki fark özellikle 2. ölçümde geç protokol lehine belirginleşmiş, diğer zaman noktalarında klinik ve istatistiksel açıdan anlamlı bir ayrışma izlenmemiştir. Bunun nedeni ilk ay geç protokol uygulanacak tarafa yükleme yapılmamışken anında yükleme tarafına bir ay boyunca yükleme yapılmış olmasıdır.

Özet (Çeviri)

Objective: This study aimed to evaluate the effect of different loading times on the stability of orthodontic mini-implants placed in the infrazygomatic crest (IZC) region using the Resonance Frequency Analysis (RFA) method. Materials and Methods: This study was a randomized, open-label, split-mouth, prospective clinical trial conducted at the Department of Orthodontics, Faculty of Dentistry, Tokat Gaziosmanpaşa University. A total of 21 volunteers were included. In each participant, 2×12 mm stainless-steel minividas (Morelli®) were inserted bilaterally into the infrazygomatic crest region. In accordance with the split-mouth design, one side was randomized to the early loading protocol (force applied at the time of insertion) and the contralateral side to the delayed loading protocol (force applied 4 weeks after insertion). Minivida stability was assessed using the Osstell® device by resonance frequency analysis, and Implant Stability Quotient (ISQ) values were recorded at 1, 2, 3, and 4 months after insertion. In addition to descriptive statistics, a two-way repeated-measures analysis of variance (protocol×time) was performed. Between-protocol comparisons at each time point were conducted using paired-samples t-tests, and Bonferroni correction was applied for multiple comparisons. The level of significance was set at p<0.05. Results: The main effect of time was significant (p<0.001), whereas the main effect of protocol was not (p=0.257). However, the protocol×time interaction was significant (p=0.003). In month-by-month comparisons, only at 2nd measurement did the delayed protocol yield significantly higher ISQ values than the anında protocol (D−I=2.57; 95% CI: 1.35–3.79; p(Bonf)=0.001); no significant differences were found at the other time points (p>0.05). Age and sex did not show a significant effect on protocol mean values (sex-related findings were considered exploratory due to the small number of male participants). Conclusion: Early and delayed loading protocols exhibit comparable overall stability levels. The difference between the protocols becomes particularly pronounced at the 2nd time point in favor of the delayed protocol, whereas no clinically or statistically meaningful divergence is observed at the other assessment time points. This pattern is likely attributable to the fact that, during the first month, no loading was applied on the side assigned to the delayed protocol, while the anında-loading side was subjected to loading throughout that month.

Benzer Tezler

  1. Sınıf III maloklüzyonlu bireylerde alternatif hızlı üst çene genişletmesi ve daraltması sonrası yüz maskesi ve iskeletsel ankraj uygulamalarının etkilerinin karşılaştırılması

    To compare the effects of alternate rapid maxillary expansion and constriction (alt-ramec) after useing face mask (FM) and skeletal anchorage (SA) with inter maxillary elastics in individuals having skeletal class iii anomaly with retrognathic maxilla in children

    SANAZ SADRY

    Doktora

    Türkçe

    Türkçe

    2015

    Süleyman Demirel Üniversitesi

    Ortodonti Ana Bilim Dalı

    Yükleniyor...

  2. Maksiller protraksiyon amacıyla kullanılan iki farklı sistemin sonlu elemanlar analizi ıle incelenmesi

    Evaluation of two different systems used for maxillary protraction by finite element analysis

    MUHAMMED ÇAĞRI ŞİBAL

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2017

    Hacettepe Üniversitesi

    Ortodonti Ana Bilim Dalı

    Yükleniyor...

  3. Üst çeneye farklı tip yüz maskeleri ile farklı açılarda uygulanan protraksiyon kuvvetlerinin dentofasiyal yapılar üzerine etkilerinin sonlu elemanlar yöntemi ile incelenmesi

    Dentofacial effects of varying the force direction on maxillary protraction with different types of face masks: A finite element analysis

    BARAN TALAY

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2016

    Cumhuriyet Üniversitesi

    Ortodonti Ana Bilim Dalı

    Yükleniyor...

  4. Comparison of stainless steel and titanium alloy infrazygomatic crest mini implants by using finite element analysis

    Paslanmaz çelik ve titanyum alaşımlı infrazigomatik mini implantların sonlu elemanlar analizi ile karşılaştırılması

    SARAH FARIS ALSABUNCHI

    Yüksek Lisans

    İngilizce

    İngilizce

    2018

    Gaziantep Üniversitesi

    Ortodonti Ana Bilim Dalı

    Yükleniyor...

  5. 3 farklı distalizasyon mekaniğinin kuvvet uygulama noktalarına göre tüm maksiller dentisyondaki distalizasyon paterninin sonlu elemanlar analizi ile incelenmesi

    Evaluation of 3 different distalization mechanics according to force application points by using finite element analysis of distalization pattern in whole maxillary dentition

    FIRAT GÖK

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2019

    Ordu Üniversitesi

    Ortodonti Ana Bilim Dalı

    Yükleniyor...