Geri Dön

Koklear implant kullanıcılarında elektrikle uyarılmış akustik değişim kompleksi yanıtları ile işitsel ayırt etme ve gürültüde anlama becerileri arasındaki ilişkinin değerlendirilmesi

Evaluation of the relationship between electrically evoked auditory change complex responses and auditory discrimination and speech understanding abilities in noise in cochlear implant users

  1. Tez No: 1013584
  2. Yazar: SERKAN DURMAZ
  3. Danışmanlar: DR. ÖĞR. ÜYESİ EYYUP KARA
  4. Tez Türü: Doktora
  5. Konular: Kulak Burun ve Boğaz, Odyoloji, Otorhinolaryngology (Ear-Nose-Throat), Audiology
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi-Cerrahpaşa
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Odyoloji Ana Bilim Dalı
  12. Bilim Dalı: Odyoloji Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Giriş ve Amaç: Koklear implant (Kİ) kullanıcılarında geleneksel ölçümler, hastaların gerçek dünyadaki karmaşık konuşma algısını ve dinleme eforunu öngörmede yetersiz kalabilmektedir. Bu çalışmanın amacı, Kİ kullanıcılarında uyaran içi değişime spesifik olarak odaklanan Elektrikle Uyarılmış Akustik Değişim Kompleksi (eADK) yanıtları ile spektral çözünürlük (SMRT) ve gürültüde konuşmayı anlama (HINT) becerileri arasındaki nörofizyolojik ilişkileri değerlendirmektir. Yöntem: Çalışmaya, yaşları 14 ile 30 arasında değişen (Ort: 19±5,69) toplam 20 Kİ kullanıcısı dâhil edilmiştir. Katılımcıların odyolojik değerlendirmelerinde Saf Ses Ortalaması (SSO), Konuşmayı Alma Eşiği (SRT), Konuşmayı Ayırt Etme Skoru (SDS), Hearing in Noise Test (HINT) ve Spectral-Temporally Modulated Ripple Test (SMRT) kullanılmıştır. Elektrofizyolojik ölçümlerde İGP N1-P2 amplitüdü, eADK N1-P2 amplitüdü ve eADK N1-İGP N1 latans farkı analiz edilmiştir. Ayrıca katılımcıların cihaz kullanım alışkanlıkları ve çevresel maruziyetleri objektif olarak kaydedilmiştir. Gruplar arası farklar ve testler arası ilişkiler istatistiksel olarak analiz edilmiştir. Bulgular: Günlük cihaz kullanım süresi fazla olan bireylerin SMRT performanslarının ve eADK N1-P2 amplitüdlerinin istatistiksel olarak daha yüksek olduğu saptanmıştır (p<0,05). Günlük yaşamlarında gürültüye fazla maruz kalan grupta davranışsal testlerde (HINT, SMRT) anlamlı bir fark görülmezken, eADK N1-P2 amplitüdünde anlamlı bir artış izlenmiştir (p<0,05). SMRT performansı yüksek olan bireylerde eADK N1-İGP N1 latans farkının daha uzun olduğu saptanmıştır. Ayrıca, eADK amplitüdü arttıkça gürültüde konuşmayı anlama (HINT SNR) performansının iyileştiği ve cihaz kullanım tecrübesi fazla olan bireylerde eADK genliğinin daha düşük olduğu görülmüştür. Sonuç: Çalışmamız, eADK'nin Kİ kullanıcılarında gürültüde konuşma algısını ve kortikal işlemleme kapasitesini öngörmede duyarlı bir biyobelirteç olduğunu göstermektedir. Günlük yaşamda maruz kalınan akustik çevrenin niteliği büyük önem taşımakta; kontrolsüz gürültü maruziyeti korteksi yorarken, temiz konuşma girdileri bilişsel aşırı yüklenmeyi önlemektedir. Uzun süreli ve aktif cihaz kullanımı, nöral verimliliği ve spektral çözünürlüğü doğrudan desteklemektedir.

Özet (Çeviri)

Introduction and Objective: Traditional measures in cochlear implant (CI) users may fall short in predicting complex speech perception and listening effort in the real world. This study aims to evaluate the neurophysiological relationships between the Electrically Evoked Auditory Change Complex (eACC) responses which specifically focus on within-stimulus changes and spectral resolution (SMRT) and speech understanding in noise (HINT) abilities in CI users. Method: A total of 20 CI users aged between 14 and 30 years (Mean: 19±5.69) were included in the study. Audiological evaluations included Pure Tone Average (PTA), Speech Reception Threshold (SRT), Speech Discrimination Score (SDS), Hearing in Noise Test (HINT), and Spectral-Temporally Modulated Ripple Test (SMRT). In electrophysiological measurements, CAEP N1-P2 amplitude, eACC N1-P2 amplitude, and eACC N1-CAEP N1 latency difference were analyzed. Additionally, participants' device usage habits and environmental acoustic exposures were objectively recorded. Inter-group differences and relationships between tests were statistically analyzed. Results: Individuals with higher daily device use time had statistically higher SMRT performances and eACC N1-P2 amplitudes (p<0.05). While no significant difference was observed in behavioral tests (HINT, SMRT) in the group highly exposed to noise in daily life, a significant increase was observed in the eACC N1-P2 amplitude (p<0.05). In individuals with high SMRT performance, the eACC N1-CAEP N1 latency difference was found to be prolonged. Furthermore, as the eACC amplitude increased, speech understanding in noise (HINT SNR) performance improved, and individuals with more device experience exhibited lower eACC amplitudes. Conclusion: Our study demonstrates that eACC is a sensitive biomarker for predicting speech perception in noise and cortical processing capacity in CI users. The quality of the acoustic environment exposed to in daily life is of great importance; while uncontrolled noise exposure fatigues the cortex, clear speech inputs prevent cognitive overload. Long-term and active device use directly supports neural efficiency and spectral resolution.

Benzer Tezler

  1. Koklear implant kullanıcılarında neural response telemetry (NRT) yöntemiyle tone decay'in değerlendirilmesi

    The evaluation of tone decay in cochlear implant users with neural response telemetry (NRT)

    FİGEN BAŞAR

    Doktora

    Türkçe

    Türkçe

    2003

    Kulak Burun ve BoğazHacettepe Üniversitesi

    Odyoloji ve Konuşma Bozuklukları Ana Bilim Dalı

    PROF.DR. EROL BELGİN

  2. Koklear implantlı hastalarda objektif ve subjektif test yöntemlerinin karşılaştırılması.

    Comparison of objective and subjective evaluation methods in cochlear implant users.

    ASLI BÖRÜ BÜLBÜL

    Yüksek Lisans

    Türkçe

    Türkçe

    2008

    Kulak Burun ve BoğazHacettepe Üniversitesi

    Odyoloji ve Konuşma Bozuklukları Ana Bilim Dalı

    DOÇ. DR. GONCA SENNAROĞLU

  3. Koklear implant kullanıcılarında elektriksel uyarılmış kortikal yanıtların araştırılması

    Investigation of electrical stimulated cortical responses in cochlear implant users

    RIŞVAN DENİZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    Kulak Burun ve Boğazİstanbul Üniversitesi-Cerrahpaşa

    Odyoloji Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ EYYUP KARA

  4. Koklear sinir anomalilerinde elektriksel uyarılmış işitsel beyin sapı yanıtları ve işitsel-sözel performansın değerlendirilmesi

    Evaluation of electrically evoked auditory brainstem responses and auditory–verbal performance in cochlear nerve anomalies

    ECEM KARTAL ÖZCAN

    Doktora

    Türkçe

    Türkçe

    2025

    Kulak Burun ve BoğazHacettepe Üniversitesi

    Odyoloji Ana Bilim Dalı

    PROF. DR. GONCA SENNAROĞLU

  5. Fasiyal sinir uyarımı (FNS) görülen koklear implant kullanıcılarında trifazik uyarım ile programlamanın incelenmesi

    Investigation of programming with triphasic stimulation in cochlear implant users with facial nerve stimulation (FNS)

    MUHAMMED EMİN GÜRKAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2022

    Kulak Burun ve Boğazİstanbul Medipol Üniversitesi

    Odyoloji Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ OĞUZ YILMAZ