Geri Dön

Karaciğer metastazlarına stereotaktik beden radyoterapisi uygulanan hastalarda, Monaco Tedavi Planlama Sisteminde Monte Carlo algoritması ile grid aralığı ve istatistiksel belirsizlik parametrelerinin doz hesaplamalarına etkisi

The effect of grid size and statistical uncertainty parameters on dose calculations using the Monte Carlo algorithm in the Monaco Treatment Planning System for patients undergoing stereotactic body radiotherapy for liver metastases

  1. Tez No: 1026072
  2. Yazar: YUNUS BAYRAM
  3. Danışmanlar: PROF. DR. MERT SAYNAK
  4. Tez Türü: Yüksek Lisans
  5. Konular: Radyasyon Onkolojisi, Radiation Oncology
  6. Anahtar Kelimeler: Stereotaktik beden radyoterapisi, monte carlo algoritması, monaco tedavi planlama sistemi, grid aralığı, istatistiksel belirsizlik, Stereotactic body radiotherapy, monte carlo algorithm, monaco treatment planning system, grid size, statistical uncertainty
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: Trakya Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Sağlık Fiziği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Giriş ve Amaç: Radyoterapide kullanılan tedavi planlama sistemlerinin doğruluğu ve verimliliği büyük önem taşımaktadır. Stereotaktik beden radyoterapisi (SBRT), karaciğer metastazları gibi küçük hacimli lezyonlarda yüksek dozların az sayıda fraksiyonda uygulanmasına olanak sağlamaktadır. Doz hesaplama doğruluğu açısından en güvenilir yöntemlerden biri olan Monte Carlo (MC) algoritması, foton etkileşimlerini fiziksel olarak modelleyerek tedavi planlarının güvenilirliğini artırmaktadır. Ancak MC hesaplamalarında kullanılan grid aralığı (GS) ve istatistiksel belirsizlik (SU) parametreleri hem hesaplama süresini hem de doz doğruluğunu etkilemektedir. Bu çalışmanın amacı, karaciğer SBRT planlarında farklı grid aralıkları (2 mm ve 3 mm) ile istatistiksel belirsizlik değerlerinin (%1 ve %2) doz hesaplamaları ve plan kalitesi üzerindeki etkilerini araştırmaktır. Gereç ve Yöntemler: Çalışma, retrospektif olarak seçilen karaciğer metastazlı hastaların SBRT planları üzerinde gerçekleştirilmiştir. Tüm planlar Monaco Tedavi Planlama Sistemi (Elekta AB, Stockholm, Sweden) kullanılarak oluşturulmuş ve Monte Carlo algoritması ile farklı grid aralığı ve istatistiksel belirsizlik kombinasyonlarında yeniden hesaplanmıştır. Hedef hacimler ve risk altındaki organlar klinik protokollere uygun şekilde tanımlanmış, optimizasyon koşulları sabit tutularak yalnızca GS ve SU parametreleri değiştirilmiştir. Planlar; doz-hacim histogramları, ortalama doz, maksimum doz, minimum doz, konformite indeksi (CI), homojenite indeksi (HI) ve hesaplama süresi açısından değerlendirilmiştir. Bulgular: Hesaplama süresinin, grid aralığı ve istatistiksel belirsizlik artışıyla birlikte istatistiksel olarak ileri düzeyde anlamlı şekilde kısaldığı saptandı (p<0,001). Grid aralığının 2 mm'den 3 mm'ye çıkarılması, hacim ortalama etkisi nedeniyle hedef hacim sarımında ve doz konformitesinde anlamlı bozulmaya neden oldu (p<0,05). Doz düşüş hızı (R50) parametresi temel olarak grid aralığındaki değişimden etkilenirken, D2cm parametresindeki bozulmanın ana kaynağının istatistiksel belirsizlik artışı olduğu gösterildi (p<0,05). Sağlam karaciğer ortalama dozları ve tüm vücut sızıntı dozlarında (V20Gy) anlamlı artışlar gözlendi (p<0,05). Gamma Passing Rate sonuçlarında ise planlar arasında anlamlı fark bulunmadı (p>0,05).Sonuç: Karaciğer SBRT planlamalarında dozimetrik hassasiyet ve hedef sarımı açısından 2 mm grid aralığı ve %1 istatistiksel belirsizlik parametreleri altın standarttır. Parametrelerin esnetilmesi (3 mm/%2) hesaplama süresini azaltmakla birlikte hedef dışı dozlarda ve sağlam karaciğer dozimetrisinde artışlara neden olmaktadır. Bununla birlikte, tüm parametre kombinasyonlarında QA başarısının benzer olması, uygun vakalarda hesaplama süresinden tasarruf amacıyla bu parametrelerin kontrollü şekilde kullanılabileceğini göstermektedir.

Özet (Çeviri)

Background and Aim: The accuracy and efficiency of radiotherapy treatment planning systems are critical for high-quality patient care. Stereotactic body radiotherapy (SBRT) enables the delivery of high radiation doses to small-volume lesions, such as liver metastases, in a limited number of fractions. The Monte Carlo (MC) algorithm is considered one of the most reliable dose calculation methods because it accurately models photon interactions. However, grid spacing (GS) and statistical uncertainty (SU) parameters affect both calculation time and dose accuracy. This study investigated the effects of different GS values (2 mm and 3 mm) and SU levels (1% and 2%) on dose calculations and plan quality in liver SBRT. Material and Methods: This retrospective study included SBRT treatment plans of patients with liver metastases. All plans were generated using the Monaco Treatment Planning System (Elekta AB, Stockholm, Sweden) and recalculated with the MC algorithm using different GS and SU combinations. Target volumes and organs at risk were delineated according to clinical protocols. Optimization settings remained unchanged, and only GS and SU parameters were varied. Plans were evaluated using dose-volume histogram parameters, conformity index (CI), homogeneity index (HI), and calculation time. Results: Calculation time decreased significantly with increasing GS and SU values (p<0.001). Increasing GS from 2 mm to 3 mm caused significant deterioration in target coverage and dose conformity because of the volume-averaging effect (p<0.05). The dose fall-off parameter (R50) was mainly influenced by GS, whereas deterioration in the D2cm parameter was primarily associated with increased SU (p<0.05). Significant increases were observed in mean healthy liver dose and whole-body leakage dose (V20Gy) when both parameters were increased (p<0.05). No statistically significant differences were found among plan combinations in Gamma Passing Rate results (p>0.05). Conclusion: A 2 mm GS and 1% SU provide the highest dosimetric accuracy and target coverage in liver SBRT planning. Although the 3 mm/2% setting reduces calculation time, it increases out-of-target doses and healthy liver exposure. Nevertheless, similar quality assurance performance among all plan combinations indicates that moderate parameter relaxation may be acceptable in selected clinical situations to reduce calculation time.

Benzer Tezler

  1. Effect of chymotrypsin on M1 type pyruvate kinase from rabbit muscle and L-type from sheep liver

    Başlık çevirisi yok

    NİLAY BAŞARAN

    Yüksek Lisans

    İngilizce

    İngilizce

    1987

    Orta Doğu Teknik Üniversitesi

    Biyokimya Ana Bilim Dalı

    Yükleniyor...

  2. Kobaylarda splenik ototransplantasyon ve postsplenektomi sepsisi

    Başlık çevirisi yok

    S.ÇAĞATAY ÇİFTER

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    Gazi Üniversitesi

    Genel Cerrahi Ana Bilim Dalı

    Yükleniyor...

  3. Bazı baharat ve ekstraktlarının gıda zehirlenmesi yapan bakteriler üzerine antimikrobiyal etkileri

    Başlık çevirisi yok

    ŞAHİKA AKTUĞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Ege Üniversitesi

    Gıda Bilimi ve Teknolojisi Ana Bilim Dalı

    Yükleniyor...

  4. Tavuk karaciğer gama-glutamil transferazının saflaştırılması ve bazı kinetik özelliklerinin araştırılması

    The Purification of the chicken liver a gamma-glutamyl transferase and the research of some kinetic properties

    FİLİZ TARCAN

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Gazi Üniversitesi

    Biyoloji Ana Bilim Dalı

    Yükleniyor...

  5. Effect of membrane fluidity on binding of 125I-Insulin to sheep liver membrane receptors

    Başlık çevirisi yok

    HÜSEYİN AVNİ ÖKTEM

    Yüksek Lisans

    İngilizce

    İngilizce

    1987

    Orta Doğu Teknik Üniversitesi

    Yükleniyor...