Geri Dön

Yapı sağlığı izleme sistemi kurulacak betonarme binalarda ivmeölçer sayısı ve yerleşim yeri için pratik bir metot geliştirilmesi

Development of a practical method for determining the number and placement of accelerometers in reinforced concrete buildings with structural health monitoring systems

  1. Tez No: 1028503
  2. Yazar: DEMET UĞUR ERGÜN
  3. Danışmanlar: PROF. DR. KÜRŞAT ESAT ALYAMAÇ
  4. Tez Türü: Yüksek Lisans
  5. Konular: İnşaat Mühendisliği, Civil Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: Fırat Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: İnşaat Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu tez çalışmasında, yapı sağlığı izleme (YSİ) sistemi kurulacak betonarme binalarda ivmeölçer sayısı ve yerleşim yerinin belirlenmesine yönelik pratik bir metot geliştirilmiştir. Mevcut optimizasyon yöntemlerinin (Etkin Bağımsızlık, genetik algoritmalar, Bayesçi yaklaşımlar) sonlu eleman modeli ve özel yazılım gerektirmesi nedeniyle mühendislik pratiğine aktarılmasının güç olması ve AFAD Yapı Sağlığı İzleme Sistemi Uygulama Yönergesi'nin yalnızca 105 m üzerindeki binalarla sınırlı kalması, bu çalışmanın temel motivasyonunu oluşturmuştur. Çalışmada öncelikle YSİ sistemlerinin kavramsal çerçevesi, sensör teknolojileri, veri toplama altyapısı ve analiz yöntemleri kapsamlı biçimde incelenmiştir. Ardından ABD, Japonya, Çin, İtalya, Kanada ve Türkiye'deki YSİ mevzuatı karşılaştırmalı olarak değerlendirilmiştir. Sensör yerleşimi alanındaki literatür 1991'den 2026'ya kadar kronolojik bir perspektifle taranarak beş döneme ayrılmış ve her dönemin temel katkıları, sınırlılıkları ve açık soruları sistematik biçimde tartışılmıştır. Bu birikimin sentezi olarak, yükseklik bandı esaslı beş adımlı bir karar yöntemi önerilmiştir. Yöntemde binalar beş yükseklik bandına (≤15, 15-30, 30-45, 45-60 ve 60-90 m) ve üç taşıyıcı sistem sınıfına (çerçeve, perde-çerçeve, perde) ayrılmakta; her sınıfın mod şekilleri sürekli kayma-eğilme kirişi modeliyle türetilmektedir. Hedef mod sayısı; yüzde 90 etkin kütle katılımı, 20 Hz izlenebilir frekans bandı ve beş katta bir donanımlı seviye uzamsal çözünürlük ölçütlerinin zarfı olarak, bant başına doğrultuda 3 ile 6 mod arasında belirlenmiştir. Donanımlı katlar, Fisher bilgi matrisinin determinantını en büyükleyen kısıtlı tam arama ile seçilmiş ve tüm bant-sistem kombinasyonlarında en büyük çapraz MAC değeri 0.28 sınırında kalarak sayısal olarak doğrulanmıştır. Toplam kanal sayısı düzenli planlı binalarda Sa = 8 + 2 × n_ara (bantlara göre 12-18), düzensiz planlı binalarda Sb = 10 + 3 × n_ara (16-25) formülleriyle hesaplanmaktadır. Yöntem, 90 m yüksekliğe kadar olan betonarme çerçeve, perde-çerçeve ve perde binalara uygulanabilmekte olup sonlu eleman modeli veya özel yazılım gerektirmemektedir. Önerilen kanal sayılarının, AFAD yönergesinin kapsam sınırına komşu 30 katlı bina senaryosunda mevzuat asgarisinin üzerinde kaldığı gösterilmiştir. Plan düzensizliğinin sensör ihtiyacını belirgin biçimde artırdığı tespit edilmiş ve bu etki doğrudan formüle edilmiştir. Ayrıca çerçeve binalarda eşit aralıklı yerleşimin en iyi çözüme yakınsadığı matematiksel olarak gösterilmiş, perde binalarda ise en iyi yerleşimin binanın orta-üst bölgesine kaydığı ortaya konmuştur.

Özet (Çeviri)

In this thesis, a practical method was developed for determining the number and placement of accelerometers in reinforced concrete buildings where structural health monitoring (SHM) systems are to be installed. The primary motivation of this study stems from the difficulty of transferring existing optimization methods (Effective Independence, genetic algorithms, Bayesian approaches) to engineering practice due to their requirements for finite element models and specialized software, combined with the limited scope of the AFAD Structural Health Monitoring System Application Directive, which applies only to buildings taller than 105 meters. The study first comprehensively examined the conceptual framework of SHM systems, sensor technologies, data acquisition infrastructure, and analysis methods. Subsequently, SHM regulations in the United States, Japan, China, Italy, Canada, and Turkey were comparatively evaluated. The literature on sensor placement was chronologically reviewed from 1991 to 2026, divided into five periods, and the key contributions, limitations, and open questions of each period were systematically discussed. As a synthesis of this body of knowledge, a height-band based five-step decision method was proposed. Buildings are classified into five height bands (≤15, 15-30, 30-45, 45-60 and 60-90 m) and three structural system classes (frame, wall-frame, wall), and the mode shapes of each class are derived from a continuous shear-flexure cantilever model. The target number of modes per band and direction (3 to 6) is defined as the envelope of three independent criteria: 90 percent effective modal mass participation, a 20 Hz identifiable frequency band, and a spatial resolution rule of one instrumented level per five storeys. Instrumented floors are selected by a constrained exhaustive search maximizing the determinant of the Fisher information matrix, and all band-system templates are verified numerically with maximum off-diagonal MAC values not exceeding 0.28. Channel counts are computed as Sa = 8 + 2 × n_int (12-18 across bands) for regular-plan buildings and Sb = 10 + 3 × n_int (16-25) for irregular-plan buildings. The method is applicable to reinforced concrete frame, wall-frame and wall buildings up to 90 m in height and does not require finite element modeling or specialized software. The proposed channel counts were shown to remain above the regulatory minimum at the 30-story scenario adjacent to the scope boundary of the AFAD directive. Plan irregularity was found to significantly increase sensor requirements, and this effect was formulated directly. Furthermore, equally spaced layouts were shown to be near-optimal for frame buildings, whereas the optimal layouts of wall buildings shift toward the mid-upper region.

Benzer Tezler

  1. Guidelines for structural health monitoring systems on tall buildings and a case study

    Yüksek binalarda kurulacak yapı sağlığı izleme sistemi standardının belirlenmesi ve örnek uygulaması

    OĞUZHAN GÜMÜŞ

    Yüksek Lisans

    İngilizce

    İngilizce

    2021

    Orta Doğu Teknik Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  2. Structural damage detection with transfer function parameter changes

    Transfer fonksiyonu parametre değişimleri ile yapısal hasar tespiti

    GÜRALP AYDEMİR

    Yüksek Lisans

    İngilizce

    İngilizce

    2021

    İstanbul Teknik Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  3. Türkiye'de su hakkı

    The right to water in Turkey

    YILDIZ AKEL ÜNAL

    Doktora

    Türkçe

    Türkçe

    2021

    Galatasaray Üniversitesi

    Kamu Hukuku Ana Bilim Dalı

    Yükleniyor...

  4. Kahverengi alanlardaki yapıların kirlenmişlik ve bozulmuşluk bağlamında yenilenmesine yönelik çevresel risk tabanlı yaklaşım önerisi

    Environmental risk based approach proposal forrenovation of buildings on brownfields in the context ofcontamination and deterioration

    HANDE APAK

    Doktora

    Türkçe

    Türkçe

    2022

    Yıldız Teknik Üniversitesi

    Mimarlık Ana Bilim Dalı

    Yükleniyor...

  5. Kimyasal ve radyolojik olaylara yönelik olarak büyükşehir raylı sistemlerinde acil durum yönetiminin modellenmesi

    Modeling of emergency management in metropolitan rail systems for chemical and radi̇ological incidents

    ENGİN KURNAZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2022

    Sağlık Bilimleri Üniversitesi

    Tıbbi Kbrn Ana Bilim Dalı

    Yükleniyor...