Femur boyun kırıkları için kullanılan vida tasarımlarının biyomekanik açıdan değerlendirilmesi

Biomechanical evaluation of screw designs used in femoral neck fractures

  1. Tez No: 1029312
  2. Yazar: SEVİL AY
  3. Danışmanlar: PROF. DR. MURAT YAYLACI, DOÇ. DR. YILMAZ GÜVERCİN
  4. Tez Türü: Doktora
  5. Konular: İnşaat Mühendisliği, Civil Engineering
  6. Anahtar Kelimeler: Biyomekanik, Femur boynu kırıkları, Sonlu elemanlar yöntemi, Biomechanics, Femoral neck fractures, Finite element method
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: Recep Tayyip Erdoğan Üniversitesi
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: İnşaat Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: İnşaat Mühendisliği Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu tezde, 70° Pauwels açısına sahip Tip III femur boyun kırıklarında farklı implant malzemeleri ile farklı implant tespit sistemlerinin biyomekanik davranışları sonlu elemanlar yöntemi ile değerlendirilmiştir. Çalışmanın temel amacı, implant malzemesi, implant tespit sistemi ve bağlantı durumunun femur-implant sisteminin mekanik davranışı üzerindeki etkilerini karşılaştırmalı olarak incelemek ve bu parametrelerin yük aktarımı ile mekanik stabilite üzerindeki etkilerini ortaya koymaktır. Bu kapsamda 30 yaşındaki bir hastaya ait BT verilerinden üç boyutlu femur modeli oluşturulmuş ve kırık geometrisi modellenmiştir. Oluşturulan model üzerinde iki farklı karşılaştırmalı sonlu eleman analizi gerçekleştirilmiştir. İlk analizde üçlü kanüllü vida sistemi kullanılarak Al2O3, CoCrMo, ZrO2, 316L paslanmaz çelik, hidroksiapatit, Ti6Al4V, ZM21 ve nadir toprak elementleri ile alaşımlandırılmış magnezyum bazlı malzemelerin (Mg-Sm, Mg-Nd, Mg-La, WE43) gerilme, şekil değiştirme ve yer değiştirme davranışları karşılaştırılmıştır. İkinci analizde ise üçlü kanüllü vida, dinamik kalça vidası ve medial destek plakası ile oluşturulan farklı implant tespit sistemlerinde sağlam ve gevşek vida bağlantı senaryoları oluşturularak bağlantı rijitliğinin sistem davranışı üzerindeki etkileri değerlendirilmiştir. Kırık arası açıklık mesafesi, maksimum şekil değiştirme, maksimum Von Mises gerilmesi ve yer değiştirme değerlerinin değerlendirildiği analizlerde, yüksek elastisite modülüne sahip implant malzemelerinde daha düşük deformasyon ve kırık açıklık mesafesi, buna karşılık daha yüksek Von Mises gerilmeleri elde edilmiştir. Magnezyum esaslı alaşımlar daha düşük gerilme seviyeleri ve daha dengeli yük aktarımı sağlamasına rağmen daha yüksek deformasyon davranışı göstermiştir. İmplant tespit sistemlerinin karşılaştırıldığı analizlerde ise medial destek plakası kullanılan sistemlerde kırık açıklık mesafesi ve maksimum şekil değiştirme değerleri azalırken, vida gevşemesinin bağlantı rijitliğini azaltarak mekanik stabiliteyi olumsuz etkilediği belirlenmiştir. Sonuç olarak, sonlu eleman analizlerinden elde edilen bulgular, implant malzemesi ve tespit sistemi geometrisi ve bağlantı rijitliğinin femur-implant sisteminin mekanik davranışını birlikte belirlediğini göstermiştir. Medial destek plakası ile güçlendirilmiş sistemler daha yüksek mekanik stabilite sağlarken, vida gevşemesi kırık hattındaki göreceli hareketi artırarak sistem davranışını olumsuz etkilemiştir. Bu yönüyle çalışma, femur boyun kırıklarının biyomekanik değerlendirilmesinde yapı mekaniği ilkeleri doğrultusunda bütüncül bir mühendislik yaklaşımı sunmaktadır.

Özet (Çeviri)

In this dissertation, the biomechanical behavior of different implant materials and fixation systems used for Pauwels Type III femoral neck fractures with a fracture angle of 70° was evaluated using the finite element method. The primary objective of this study was to comparatively investigate the effects of implant material, fixation system, and connection condition on the mechanical behavior of the femur–implant system and to reveal the influence of these parameters on load transfer and mechanical stability. Within this scope, a three-dimensional femur model was reconstructed from the CT data of a 30-year-old patient, and a fracture geometry representing a Pauwels Type III femoral neck fracture was created. Two comparative finite element analyses were performed on the developed model. In the first analysis, a three cannulated screw fixation system was used to compare the stress, strain, and displacement behaviors of conventional orthopedic implant materials, including Al2O3, CoCrMo, ZrO2, 316L stainless steel, hydroxyapatite, Ti6Al4V, and ZM21, together with rare earth element-alloyed magnesium-based materials (Mg-Sm, Mg-Nd, Mg-La, and WE43). In the second analysis, different fixation systems consisting of three cannulated screws, a dynamic hip screw, and a medial buttress plate were evaluated under intact and loosened screw connection scenarios to investigate the effect of connection stiffness on the mechanical behavior of the femur-implant system. Crack distance, maximum strain, maximum von Mises stress, and displacement were evaluated to compare the mechanical performance of different implant materials and fixation systems. The analyses demonstrated that implant materials with higher elastic modulus exhibited lower deformation and fracture gap distances but higher von Mises stresses. Although magnesium-based alloys showed greater deformation, they provided lower stress levels and a more homogeneous load transfer. In the comparison of fixation systems, models reinforced with a medial buttress plate exhibited reduced fracture gap distances and lower maximum strain values, whereas screw loosening decreased connection stiffness and adversely affected the mechanical stability of the system. In conclusion, the finite element analyses demonstrated that implant material, fixation system geometry, and connection stiffness collectively govern the mechanical behavior of the femur-implant system. Fixation systems reinforced with a medial buttress plate provided superior mechanical stability, whereas screw loosening increased the relative movement at the fracture site and negatively affected the overall mechanical response. Accordingly, this study presents a comprehensive engineering approach for the biomechanical evaluation of femoral neck fractures based on the fundamental principles of structural mechanics.

Benzer Tezler

  1. Doğuştan kalça çıkıklı hastalarda kalça patolojilerinin bilgisayarlı tomografi ile değerlendirilmesi

    Başlık çevirisi yok

    NECDET ŞÜKRÜ ALTUN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    Gazi Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    Yükleniyor...

  2. Gazi tipi eksternal fiksatörlerle yapılan uygulamalarda kırık hattındaki kompresyonun biyomekanik olarak“strain gage”lerle tayini

    Başlık çevirisi yok

    HÜSEYİN ŞENGÜL

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    Gazi Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    Yükleniyor...

  3. Çinkonun eritrosit membran akışkanlığına etkisi

    Başlık çevirisi yok

    ABDURRAHMAN ŞERMET

    Doktora

    Türkçe

    Türkçe

    1986

    Akdeniz Üniversitesi

    Fizyoloji Ana Bilim Dalı

    Yükleniyor...

  4. Femur boyun bölgesi kırıklarının kompresyonlu ve kayıcı kalça çivileri ile tedavisi

    Başlık çevirisi yok

    OSMAN UĞUR ÇALPUR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1985

    İstanbul Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    Yükleniyor...