Kedilerde kan hemoglobin konsantrasyonu ve hematokrit değer ölçümünde bir el analizatörünün kullanılabilirliği
Usability of a handheld analyzer for the measurement of blood hemoglobin concentration and hematocrit value in cats
- Tez No: 1029366
- Danışmanlar: PROF. DR. HÜSEYİN VOYVODA
- Tez Türü: Yüksek Lisans
- Konular: Veteriner Hekimliği, Veterinary Medicine
- Anahtar Kelimeler: Bakım noktası testi, hematokrit, hemoglobin, kedi, Cat, hematocrit, hemoglobin, point-of-care testing
- Yıl: 2026
- Dil: Türkçe
- Üniversite: Aydın Adnan Menderes Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Veterinerlik İç Hastalıkları Ana Bilim Dalı
- Bilim Dalı: İç Hastalıkları (veterinerlik) Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
ÖZET KEDİLERDE KAN HEMOGLOBİN KONSANTRASYONU VE HEMATOKRİT DEĞER ÖLÇÜMÜNDE BİR EL ANALİZATÖRÜNÜN KULLANILABİLİRLİĞİ Turhan S. Aydın Adnan Menderes Üniversitesi, Sağlık Bilimleri Enstitüsü, Veterinerlik İç Hastalıkları Programı, Yüksek Lisans Tezi, Aydın, 2026. Amaç: İnsanlarda kullanım için geliştirilen, kan hemoglobin (Hb) konsantrasyonu ve hematokrit değer (Hct) hasta başı analiz cihazının (POCT Acon Mission Ultra) kedilerde kullanılabilirliğini, altın standart olarak kabul edilen yöntemlerle karşılaştırarak değerlendirilmesidir. Gereç ve Yöntem: Çalışmada, 86 kediden alınan EDTA'lı venöz kan örnekleri değerlendirildi. Kediler, genel (N=86), sağlıklı (n=33), anemik (n=43) ve eritrositozlu (n=10) olarak gruplandırıldı. Otomatik kan sayım cihazında (Abacus VET5) ölçülen Hb konsantrasyonu, mikrohematokrit yöntemle belirlenen paketlenmiş hücre hacmi (PCV) altın standart kabul edildi. Yöntemler arası uyum Bland-Altman ve Passing-Bablok regresyon analizleri, cihazın anemi tespitindeki tanısal doğruluğu da duyarlılık, özgüllük ve tahmin değerleri ile belirlendi. Bulgular: Genel grupta, test cihazıyla ölçülen ortanca Hb (8,0 g/dL) ve Hct (%21,9) değer, standart yöntem Hb (8,65 g/dLHb (PCV (%24,5) değere göre anlamlı düzeyde (her ikisi p<0,001) düşük bulundu. İki yöntem arasında Hb (rho= 0,96) ve Hct (rho=93) ölçümlerinde yüksek korelasyonlar belirlendi. Passing-Bablok regresyon analizi, Hct değerde sabit ve oransal sapmanın, Hb konsantrasyonunda ise sabit sapmanın varlığını ortaya koydu Cihaz, genel grupta Hb ölçümü için ortalama 1,09 g/dL (%95 uyum sınırları [LOA]: −3,13 ile 0,94) ve Hct ölçümü için −%2,08 (%95 LOA: −11,04 ile 6,87) sapma gösterdi.Total analitik hata (%TAH) Hb ve Hct için sırasıyla %9,52 ve %13,83 olarak hesaplandı. Anemiyi belirlemede test cihazının Hb için duyarlılık ve özgüllük %95,3, Hct için ise sırasıyla %97,7 ve %86,0 olarak bulundu. Sonuç: Mission Ultra cihazı, kedilerde Hb ölçümünde kullanılabilir, Hct yorumu ise alt referans değer ve yakınında dikkatli yapılmalıdır.
Özet (Çeviri)
ABSTRACT USABILITY OF A HANDHELD ANALYZER FOR THE MEASUREMENT OF BLOOD HEMOGLOBIN CONCENTRATION AND HEMATOCRIT VALUE IN CATS Turhan S. Aydin Adnan Menderes University, Graduate School of Health Sciences, Department of Veterinary Internal Medicine, Master's Thesis, Aydın, 2026. Objective: This study aimed to evaluate the clinical utility of a point-of-care testing (POCT) analyzer (Acon Mission Ultra), originally designed for human use, for determining blood hemoglobin (Hb) concentration and hematocrit (Hct) values in cats in comparison with gold-standard methods. Materials and Methods: In the study, EDTA venous blood samples obtained from 86 cats were evaluated. The cats were categorized as overall (N=86), healthy (n=33), anemic (n=43), and erythrocytosis (n=10) for analysis. The Hb concentration measured by an automated blood cell counter (Abacus VET5) and the packed cell volume (PCV) determined by the microhematocrit method were accepted as the gold standard. Agreement between methods was determined by Bland-Altman and Passing-Bablok regression analyses, and the diagnostic accuracy of the device in detecting anemia was determined by sensitivity, specificity, and predictive values. Results: The median Hb (8.0 g/dL) and Hct (21.9%) values measured by the device were found to be significantly (both p<0.001) lower than the standard method Hb (8.65 g/dL) and Hct (24.5%) values in overall. High correlations were observed between the two methods for Hb measurement (rho = 0.96) and Hct measurement (rho = 0.93). Passing-Bablok regression analysis demonstrated the presence of both constant and proportional bias for Hct value, and a constant bias for Hb concentration. The device showed average biases of 0.76 g/dl (95% limits of agreement [LOA]: −1.03 to 2.54) for Hb measurement and −2.73% (95% LOA: −9.28 to 3.82) for Hct measurement in overall. The total analytical error (TAE) values were calculated as 9.52% for Hb and 13.83% for Hct. The sensitivity and specificity of the device in detecting anemia were found to be both 95.3% for Hb, and 97.7% and 86.0% for Hct, respectively. Conclusion: The Mission Ultra device can be used for Hb measurement in cats; however, Hct interpretation should be performed with caution at and near the lower reference value.
Benzer Tezler
- Manisa yöresinde demir eksikliği anemi prevalansı ve demir eksikliği anemisinde tarama testi olarak rutin hemogram, RDW ve ferritinin kullanımı
The prevalance of iron deficieny anemia in Manisa and using of hemogram, RDW and ferritin for searcing of iron deficiency anemia
VİLDAN ÜRK TAŞYENEN
Tıpta Uzmanlık
Türkçe
2006
Celal Bayar ÜniversitesiÇocuk Sağlığı ve Hastalıkları Ana Bilim Dalı
Yükleniyor...
- Kistik endometriyal hiperplazi-pyometra kompleks olan kedilerde ovariyohisterektomi anında ve sonrasında bazı hematolojik ve biyokimyasal parametrelerinin incelenmesi
Evaluation of some hemotological and biochemical parameters during and after ovariohysterectomy in queens suffered from cystic endometrial hyperplasia-pyometra complex
ANIL TOPCU
Yüksek Lisans
Türkçe
2020
Afyon Kocatepe ÜniversitesiVeterinerlik Doğum ve Jinekolojisi Ana Bilim Dalı
Yükleniyor...
- Pyometralı kedilerde serum amiloid düzeylerinin hematolojik ve biyokimyasal parametrelerle birlikte değerlendirilmesi
Evaluation of serum amyloid levels with hematological and biochemical parameters in cats with pyometra
RÜŞTÜ KARATAŞ
Yüksek Lisans
Türkçe
2023
Burdur Mehmet Akif Ersoy ÜniversitesiVeterinerlik Doğum ve Jinekolojisi Ana Bilim Dalı
Yükleniyor...
- Demir eksikliği ile birlikte olan talassemi traitlerde HbA2 ile diğer hematolojik parametreler ve demir tedavisine yanıt
Başlık çevirisi yok
MEHMET CAN
Tıpta Uzmanlık
Türkçe
1991
İstanbul ÜniversitesiÇocuk Sağlığı ve Hastalıkları Ana Bilim Dalı
Yükleniyor...
- Klinik olarak pnömoni tespit edilen keçilerde serum amiloid-A (SAA) seviyesinin belirlenmesi
Determination of serum amyloid-A levels in clinically detected pneumonia in goats
KADİR DEMİRBAŞ
Yüksek Lisans
Türkçe
2019
Afyon Kocatepe ÜniversitesiVeterinerlik İç Hastalıkları Ana Bilim Dalı
Yükleniyor...