Cyberknife ve Radixact cihazlarında oluşturulan radyoterapi tedavi planlarında bağımsız doz hesaplamanın rolü ve klinik uygulamaları
The role and clinical practices of secondary dose calculation in radiotherapy treatment plans created with Cyberknife and Radixact
- Tez No: 1030545
- Danışmanlar: DOÇ. DR. DİLEK DÜZGÜN ERGÜN
- Tez Türü: Yüksek Lisans
- Konular: Radyasyon Onkolojisi, Radiation Oncology
- Anahtar Kelimeler: Kalite kontrol, Monte Carlo Yöntemi, Quality control, Monte Carlo Method
- Yıl: 2026
- Dil: Türkçe
- Üniversite: İstanbul Aydın Üniversitesi
- Enstitü: Lisansüstü Eğitim Enstitüsü
- Ana Bilim Dalı: Yazılım Mühendisliği Ana Bilim Dalı
- Bilim Dalı: Sağlık Fiziği Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
Radyoterapi uygulamalarında, Tedavi Planlama Sistemi (TPS) yazılımları aracılığıyla oluşturulan tedavi planlarında hedef hacim (PTV) ve risk altındaki organların (OARs) hesaplanan dozları, tedavi hastaya uygulanmadan önce bağımsız bir yazılım aracılığıyla doğrulanması, Amerikan Tıbbi Fizikçiler Derneği Görev Grubu 219 (AAPM TG-219) tarafından önerilmektedir. İkincil Doz Kontrolü (İDK) olarak adlandırılan ve hastaya verilecek radyasyon dozunun doğruluğunun teyidi için yapılan bu kalite kontrol işleminde altın standart kabul edilen Monte Carlo (MC) tabanlı algoritmalarla planlar tekrar hesaplanarak orijinal plan ile benzerliğine bakılmaktadır. İDK, radyoterapide standart kabul edilen doğrusal hızlandırıcı cihazlarında kullanımı nispeten yaygın olmak ile birlikte Radixact® ve Cyberknife® gibi özelleşmiş cihazlarda kullanımı çeşitli nedenlerden dolayı son derece sınırlıdır. Bu tez çalışmasının amacı farklı anatomik bölgeler için farklı cihaz ve TPS sistemlerinde oluşturulan tedavi planlarının İDK için özel hazırlanmış MC tabanlı myQA® iON yazılımı ile doğruluğunu araştırmaktır. Bu çalışmada değerlendirilen toplam 30 tedavi planının 15 tanesi CyberKnife cihazında beyin metastazına yönelik Stereotaktik Radyoterapi Tekniği (SRT) ve Ray-Tracing (RT) hesaplama algoritması kullanılarak, diğer 15 tanesi ise Radixact cihazında primer prostat tümörüne ve pelvik lenf nodlarına yönelik helikal Yoğunluk Ayarlı Radyoterapi Tekniği (IMRT) ve Collapsed Cone Convolution (CCC) hesaplama algoritması kullanılarak oluşturulmuştur. Değerlendirme hedef ve organ bazlı gamma indeks analizleri (GIA) hesaplamaları ve doz-hacim histogramları (DVH) kullanılarak yapılmıştır. Her iki anatomik bölge için yapılan GIA ve DVH plan karşılaştırmalarında birbirleri ile uyumlu sonuçlar bulunmuştur.
Özet (Çeviri)
In radiotherapy practice, it is recommended that the doses calculated for target volumes (PTV) and organs at risk (OARs) within treatment plans generated by Treatment Planning System (TPS) software be verified using an independent dose calculation software prior to treatment delivery. This recommendation has been put forward by the American Association of Physicist in Medicine Task Group 219 (AAPM TG-219). In the quality assurance process known as Secondary Dose Calculation (SDC), which is performed to confirm the accuracy of the radiation dose to be delivered to the patient, treatment plans are typically recalculated using Monte Carlo (MC)–based algorithms, which are considered the gold standard, and the results are compared with the original plan to evaluate their similarity. Although the use of SDC is relatively common in conventional linear accelerator systems, which are considered the standard in radiotherapy, its application in more specialized systems such as Radixact® and CyberKnife® remains extremely limited due to various reasons. The aim of this study is to investigate the accuracy of the treatment plans generated for different anatomical regions using various devices and TPS platforms through the MC-based SDC algorithm in the myQA® iON software. In this study, a total of 30 treatment plans were analyzed. Fifteen plans were generated for the CyberKnife system employing the Stereotactic Radiotherapy Technique (SRT) for brain metastases with the Ray-Tracing (RT) dose calculation algorithm, whereas the remaining fifteen plans were generated for the Radixact system employing the helical Intensity-Modulated Radiotherapy Technique (IMRT) for primary prostate tumors and pelvic lymph nodes with the Collapsed Cone Convolution (CCC) dose calculation algorithm.The evaluation was performed using target- and organ-based gamma index analysis (GIA) and dose–volume histograms (DVHs). In the plan comparisons based on GIA and DVH for both anatomical regions, the results were found to be in strong agreement.
Benzer Tezler
- Cyberknife robotik radyocerrahi cihazında farklı anotomik yerleşimli tümörlerde gonadların aldığı dozun belirlenmesi
Determination of gonad dose at cyberknife robotic radiosurgery for several tumor treatments
GÖZDE DÜĞEL
- CyberKnife robotik radyocerrahi cihazinda kullanilan küçük alanlarin dozimetrisinin farkli sistemler kullanilarak incelenmesi
The dosimetric evaluation of small fields of CyberKnife robotic radiosurgery unit with various dosimetric systems
TALİP YOLCU
- İleri evre küçük hücreli dışı akciğer kanserinde kemoterapi sonrası FDG-PET/BT'deki metabolik cevabın prognoz üzerine etkisi
The prognostic relevance of response evaluation to chemotherapy using FDG-PET/CT in patients with advanced stage non-small-cell lung cancer
ÇETİN ORDU
- Robotik radyocerrahi uygulanan beyin ve spinal tümörlü hastalarda tedavi sonuçlarımızın değerlendirilmesi
Therapeutic results in patients with brain and spinal tumors treated with robotic radiosurgery
AYŞEN AYDIN
- Antioksidan ajanların deneysel olarak oluşturulan radyasyona bağlı akciğer fibrozu üzerinde etkinliğinin histopatolojik olarak değerlendirilmesi
Histopathological evaluation of antioxidants' effectiveness on experimentally radiation induced lung fibrosis
BİLGEHAN ŞAHİN