Investigation of novel approaches based on vibrational spectroscopy techniques for rapid detection and quantitative analysis of kidney disease biomarkers in blood
Böbrek hastalığı biyobelirteçlerinin kanda hızlı tespiti ve kantitatif analizi için titreşim spektroskopi tekniklerine dayalı yeni yaklaşımların araştırılması
- Tez No: 1032674
- Danışmanlar: DOÇ. DR. GÜNNUR GÜLER
- Tez Türü: Yüksek Lisans
- Konular: Biyofizik, Fizik ve Fizik Mühendisliği, Biophysics, Physics and Physics Engineering
- Anahtar Kelimeler: Böbrek yetmezliği-kronik, FTIR, Hemodiyaliz, Infrared spektroskopi, Kidney failure-chronic, FTIR
- Yıl: 2026
- Dil: İngilizce
- Üniversite: İzmir Yüksek Teknoloji Enstitüsü
- Enstitü: Lisansüstü Eğitim Enstitüsü
- Ana Bilim Dalı: Fizik Ana Bilim Dalı
- Bilim Dalı: Fizik Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
Kronik böbrek hastalığı (KBH), her 7 yetişkinden 1'ini etkilemekte ve hastalar için külfetli olan hemodiyaliz (HD) tedavisini gerektirmektedir. Bu çalışmada, diyaliz hastalarında üre, kreatinin ve glukoz düzeylerinin izlenmesi için hızlı ve etiketleme gerektirmeyen bir yöntem olarak Zayıflatılmış Toplam Yansıma-Fourier Dönüşümlü Kızılötesi (ATR-FT-IR) spektroskopisi, Raman spektroskopisi desteğiyle değerlendirilmiştir. Kalibrasyon serileri PBS (fosfat tamponlu salin) ve tam kanda hazırlanmış, biyomolekül kombinasyonları girişim açısından test edilmiştir. Etik kurul onayı kapsamında, HD öncesi ve sonrası KBH hastalarından (n=9) tam kan, ayrıca heparinize (n=5) örnekler ve serum (n=4) örnekleri toplanmıştır. Spektrumlar alan normalize edilmiş, baz çizgisi düzeltilmiş, su ve heparin çıkarımı yapılmış, hastaneden alınan biyokimya test sonuçlarıyla karşılaştırılmıştır. HD ile ilişkili değişiklikleri ve numune işleme etkisini değerlendirmek amacıyla spektrumlara Student t-testi ve PCA uygulanmıştır. PBS'de üç metabolit de güçlü doğrusallık göstermiş (R²>0,99), tam kanda azalmıştır. BSA, 1160 cm⁻¹'de üre yoğunluğunun iki katından fazlasına katkıda bulunmuş; sinyalin toplamsal olmaması kısmi protein girişimine işaret etmiştir. Üre ve kreatinin bantları HD sonrasında azalmış; 1160 cm⁻¹ bandı, üre tayini için en uygun bant olarak öne çıkmış ve biyokimyayla en güçlü korelasyonu göstermiştir (R²=0,73). Raman analizi, kandaki üre tepkisini bağımsız olarak doğrulamıştır. Bu bulgular, ATR-FT-IR'in hemodiyaliz takibinde tamamlayıcı bir araç olabileceğini desteklemekte ve reaktifsiz hemodiyaliz izlemine yönelik Kuantum Çağlayan Lazer (QCL) tabanlı biyosensör geliştirme çalışmaları için temel oluşturmaktadır; ancak protein girişimi ve hastalar arası değişkenlik klinik uygulamaya geçişte temel zorluklar olarak kalmaktadır.
Özet (Çeviri)
Chronic kidney disease (CKD) affects 1 in 7 adults and requires hemodialysis (HD), which is burdensome for patients. This study evaluated Attenuated Total Reflectance-Fourier Transform Infrared (ATR-FT-IR) spectroscopy, supported by Raman spectroscopy, as a rapid, label-free method for monitoring urea, creatinine, and glucose in dialysis patients. Calibration series were prepared in phosphate- buffered saline (PBS) and whole blood, with biomolecule combinations tested for interference. Whole-blood samples were collected from CKD patients (n=9) before and after HD under ethical approval. Spectra were area-normalized, baseline- corrected, and water- and heparin-subtracted, then compared with clinical biochemistry results. Student's t-test and PCA were applied to pre- and post-HD spectra to assess HD-associated changes and sample-handling effects, including tube type and preparation processes. In PBS, all metabolites showed strong linearity (R²>0.99), decreasing in whole blood. BSA contributed more than twice the urea intensity around 1160 cm⁻¹, with the combined signal not directly additive, indicating partial protein interference. Across patients, urea and creatinine bands decreased after HD, with 1160 cm⁻¹ emerging as the most suitable band for urea determination and showing the strongest correlation with biochemistry (R²=0.73). Raman analysis independently confirmed the urea response in blood. These findings support ATR- FT-IR as a complementary tool for HD monitoring and provide groundwork for reagent-free quantum cascade laser (QCL)-based biosensor studies, while protein interference and inter-patient variability remain key translational challenges.
Benzer Tezler
- Femtosaniye lazer ile işlenen yapıların katıhal lazerlerde uygulamaları ve üst çevrim pompalı Tm3+:KY3F10 lazerleri
Solid-state laser applications of femtosecond laser written structures and upconversion pumped Tm3+:KY3F10 lasers
YAĞIZ MOROVA
- İletken anilin, triflorometil-anilin ve diamino-disiyano-antrakinon polimerlerinin sentezi ve karakterizasyonu
Synthesis and characterization of conductive aniline, trifluoromethyl aniline, and diamino-dicyano anthraquinone polymers
SEVİL GÜNERALP
- Heterohalkalı tiyazolo tiyazol bileşiklerininsentezi ve spektroskopik özellikleri
Synthesis and spectroscopic properties of heterocyclic thiazolo thiazole compounds
HİKMET BURCU GÜNESER
- İzmir'de bazı yolların kapatılarak yaya bölgeleri oluşturma da kent peyzajını geliştirme açısından yeniden planlanması üzerinde araştırmalar
Başlık çevirisi yok
BAHAR TÜRKYILMAZ
- Kuyruk modelleri ve analizi üzerine bir uygulama
Başlık çevirisi yok
DİDEM ÖZPULAT
Yüksek Lisans
Türkçe
1985
Ege ÜniversitesiBilgisayar Bilimleri ve Mühendisliği Ana Bilim Dalı
Yükleniyor...