Assessment of radiated electromagnetic susceptibility in electronic devices according to military and commercial electromagnetic interference standards

Askerî ve ticari elektromanyetik girişim standartlarına göre elektronik cihazların ışınımla oluşan elektromanyetik duyarlılığının değerlendirilmesi

  1. Tez No: 1032742
  2. Yazar: ELİFNUR KARA
  3. Danışmanlar: PROF. DR. FATİH ÜSTÜNER
  4. Tez Türü: Yüksek Lisans
  5. Konular: Elektrik ve Elektronik Mühendisliği, Electrical and Electronics Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2026
  8. Dil: İngilizce
  9. Üniversite: İstanbul Ticaret Üniversitesi
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Elektrik ve Elektronik Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Elektrik Elektronik Mühendisliği Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu tezde, ticari hazır (COTS) ekipmanların askeri platformlarda giderek artan kullanımıyla birlikte elektromanyetik uyumluluk (EMC) mühendisliğinde ortaya çıkan önemli bir problem ele alınmaktadır: sivil RF bağışıklık standartlarına göre nitelendirilmiş ekipmanların askeri RF bağışıklık gereksinimlerini karşılayıp karşılamadığının belirlenmesi. Bu kapsamda çalışma, iki farklı yayılan RF bağışıklık test yöntemini karşılaştırmaktadır: askeri standart MIL-STD-461G kapsamında tanımlanan RS103 RF duyarlılık testi ile ticari standart IEC 61000-4-3. Her iki test düzeneği, 30–300 MHz frekans aralığında, yatay ve dikey polarizasyon koşulları altında Altair FEKO kullanılarak modellenmiş ve simüle edilmiştir. İki simülasyon modeli geliştirilmiştir. İlk modelde, her bir test düzeneğinin ekipman kablosu üzerinde indüklediği parazit akımlarının etkinliği tek iletkenli bir kablo üzerinden karşılaştırılmıştır. İkinci modelde ise kablo, iletkenler arasında 2 mm yükseklik farkı bulunan ve standart bir sonlandırma ağı içeren iki telli RS-485 diferansiyel arayüzüyle değiştirilmiştir. Duyarlılık ölçütü olarak ekipman uçlarındaki diferansiyel mod gerilimi esas alınmıştır. İlk model sonuçları, IEC 61000-4-3 test düzeneğinin aynı aydınlatma elektrik alanı seviyesinde RS103 düzeneğine kıyasla sürekli olarak daha yüksek ortak mod akımları indüklediğini göstermektedir. Bu doğrultuda, 10 V/m IEC sürekli dalga alanının RS103 düzeneğinde en az 18,7 V/m'ye karşılık geldiği; %80 genlik modülasyonu dikkate alındığında bu değerin 33 V/m'ye yükseldiği belirlenmiştir. İkinci model sonuçları ise daha karmaşık bir davranışa işaret etmektedir. Frekans aralığının büyük bölümünde IEC test düzeneği daha yüksek diferansiyel mod gerilimleri üretmekle birlikte, RS103 düzeneği test ortamının yansıtıcı karakteristiğinden kaynaklanan belirli rezonans frekanslarında daha yüksek değerler üretmektedir. Bu durum, ilk modelden çıkarılan genellemenin gerçekçi diferansiyel sinyal arayüzleri söz konusu olduğunda geçerliliğini yitirdiğini ortaya koymaktadır. Sonuç olarak, IEC 61000-4-3 nitelendirmesinin diferansiyel arayüzlere sahip COTS ekipmanlar için askeri RF duyarlılık gereksinimlerini değerlendirmede makul ancak yeterli olmayan bir gösterge sunduğu anlaşılmaktadır. Mühendislerin ticari bağışıklık test sonuçlarını yorumlarken kablo geometrisi, arayüz yapısı ve sonlandırma koşullarını da kapsamlı biçimde değerlendirmeleri önerilmektedir.

Özet (Çeviri)

The growing use of commercial-off-the-shelf (COTS) equipment in military platforms has created an important challenge in electromagnetic compatibility (EMC) engineering: determining whether equipment qualified under civilian RF immunity standards also satisfies military RF immunity requirements. This thesis investigates this challenge by comparing two radiated RF immunity test methodologies — RS103, the radiated susceptibility test defined in MIL-STD-461G, and IEC 61000-4-3, the commercial radiated RF immunity standard. Both test setups were modelled and simulated using Altair FEKO over 30–300 MHz under horizontal and vertical polarization conditions. Two simulation models were developed. In the first model, a single-conductor cable was used to compare how efficiently each test setup induces interference currents on the equipment cable. In the second model, the cable was replaced with a two-wire RS-485 differential signaling interface with a 2 mm height difference between conductors and a standard termination network. The differential-mode voltage at the equipment terminals was used as the susceptibility metric. The first model showed that the IEC 61000-4-3 test setup consistently induces higher common-mode currents for the same illuminating electric field, demonstrating that a 10 V/m IEC continuous-wave field corresponds to at least 18.7 V/m in the RS103 setup, rising to 33 V/m when the 80% amplitude modulation factor is considered. The second model revealed a more complex picture. While the IEC setup produces higher differential-mode voltages across most of the frequency range, the RS103 setup produces higher values at resonance frequencies due to its reflective test environment. This means the conclusion from the first model does not hold when a realistic differential signaling interface is considered. These findings suggest that IEC 61000-4-3 qualification provides a reasonable but not complete indicator of military RF susceptibility compliance for COTS equipment. Engineers should account for cable geometry, interface type, and termination conditions when interpreting commercial immunity test results.

Benzer Tezler

  1. Elektromanyetik uyumluluk (EMC) deneylerinin fiziksel analizi ve 900/1800 MHz GSM bandında iletim ve ışınım deneylerinin değerlendirilmesi

    Physical analyse of electromagnetic compatibility tests and, assesment of conducted and radiated tests to 900/1800 MHz GSM bandwith

    TUĞFAN KARABULUT

    Yüksek Lisans

    Türkçe

    Türkçe

    2011

    Gazi Üniversitesi

    Fizik Ana Bilim Dalı

    Yükleniyor...

  2. Spesific absorption rate assessment in a human head model exposed to radiation from cellular phone

    Cep telefonundan kaynaklanan ışımaya maruz kalan bir insan kafasında enerji soğurulma oranının değerlendirilmesi

    BİNAY ÖZSOY DEMİRBİLEK

    Yüksek Lisans

    İngilizce

    İngilizce

    2001

    Boğaziçi Üniversitesi

    Biyomedikal Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  3. Anahtarlamalı güç kaynaklarında oluşan harmoniklerin elektromanyetik uyumluluk üzerine etkileri ve filtre tasarım yaklaşımları

    Effects of noise caused by harmonics generated in switched mode power supply on EMI/EMC and filtering studies

    YUNUS FURKAN DİLMEN

    Yüksek Lisans

    Türkçe

    Türkçe

    2026

    Sakarya Üniversitesi

    Elektrik ve Elektronik Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  4. Design of a compact bidirectional rf front-end module for 24–30 GHz 5g applications

    24-30 GHz 5g uygulamaları için kompakt çift yönlü rf ön uç modülü tasarımı

    HÜSEYİN CAHİT ERBİL

    Yüksek Lisans

    İngilizce

    İngilizce

    2026

    İstanbul Teknik Üniversitesi

    Elektronik ve Haberleşme Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  5. Askeri cihazlarda bağlantı yollu elektromanyetik girişim bastırma çalışması

    Electromagnetic noise suppression study with connection path in military devices

    MUSA ŞAGAR

    Yüksek Lisans

    Türkçe

    Türkçe

    2023

    Sakarya Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    Yükleniyor...