Geri Dön

Türkçe kraniyal bt raporlarının yapılandırılması ve acil bulguların işaretlenmesi için ince ayarlı kompakt bir büyük dil modelinin geliştirilmesi

Development of a fine-tuned compact large language model for structuring turkish head ct reports and flagging urgent findings

  1. Tez No: 1032813
  2. Yazar: AHMET HARUN TURGAN
  3. Danışmanlar: DOÇ. DR. ZAKİR SAKCI
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Radyoloji ve Nükleer Tıp, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Acil Durumlar, Büyük Dil Modelleri, Doğal Dil İşleme, Radyoloji Bilgi Sistemleri, Tomografi, X-Işınlı Bilgisayarlı, Emergencies, Large Language Models, Natural Language Processing, Radiology Information Systems, Tomography, X-Ray Computed
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: Sağlık Bilimleri Üniversitesi
  10. Enstitü: İstanbul Ümraniye Sağlık Uygulama ve Araştırma Merkezi
  11. Ana Bilim Dalı: Radyoloji Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Türkçe kraniyal bilgisayarlı tomografi (BT) raporlarını yapılandıran ve acil bulguları işaretleyen, yerel olarak çalışabilen kompakt bir dil modeli geliştirmek ve göreve özgü ince ayarın katkısını değerlendirmek. Gereç ve Yöntem: Retrospektif, tek merkezli çalışmaya 8.413 kontrastsız kraniyal BT raporu dahil edildi. Ticari bir dil modeliyle, radyolog denetiminde 16 alanlı gümüş standart etiketler oluşturuldu ve MedGemma 4B modeli QLoRA yöntemiyle ince ayardan geçirildi. Ayrılmış 844 raporluk test setinde model, anahtar kelime kuralları ve sıfır-atış MedGemma 4B ve 27B ile karşılaştırıldı. Referans, ince ayarlı model ya da 27B'nin gümüş etiketlerle uyuşmadığı 155 rapor ve 45 kontrol raporunda kör radyolog değerlendirmesiyle kısmen hakemlendi. Üç radyolog, aralarına 20 kasıtlı bozulmuş çıktı karıştırılan 150 yapılandırılmış çıktıyı kabul edilebilirlik açısından değerlendirdi. Bulgular: Bileşik referansa göre 171 acil raporun 169'unu ince ayarlı MedGemma 4B doğru işaretledi (duyarlılık %98,8; özgüllük %90,8); aynı model ince ayar öncesinde sıfır-atış (tam istem) kullanıldığında 107 acil raporu kaçırmıştı (tanımlayıcı karşılaştırma). Yaklaşık yedi kat büyük sıfır-atış MedGemma 27B 111 acil raporu saptadı (duyarlılık %64,9; özgüllük %99,4; ince ayarlı modelle duyarlılık ve özgüllük farkları için p<0,001). Olumsuzlama duyarlı kurallar 29 raporu kaçırdı; 1.000 raporda yanlış alarm ince ayarlı modelde 73, MedGemma 27B'de 5 idi. Geliştirme setinin kopyası olan test raporları dışlandığında duyarlılık değişmedi, özgüllük %85,4'e geriledi. Okuyucular çıktıların %88,0'ını kabul edilebilir buldu ve 20 bozulmanın 19'unu en az biri saptadı. xi Sonuç: Türkçe kraniyal BT raporlarına göre ince ayarlanan kompakt model, çalışmada kullanılan sıfır-atış karşılaştırma sistemlerinden daha yüksek acil bulgu duyarlılığı göstermiştir. Bunun bedeli daha fazla yanlış alarmdır. Bu yaklaşım, imzalanmış raporlarda belirtilen acil bulguların bildiriminin desteklenmesi için umut vericidir; klinik kullanım öncesinde bağımsız ve ileriye dönük doğrulama gereklidir.

Özet (Çeviri)

Aim: To develop a compact, locally deployable language model that structures Turkish head computed tomography (CT) reports and flags urgent findings, and to assess the contribution of task-specific fine-tuning. Materials and Methods: This retrospective single-center study included 8,413 non-contrast head CT reports. Sixteen-field silver-standard labels were generated with a proprietary language model under radiologist oversight, and MedGemma 4B was fine-tuned with QLoRA. On a held-out 844-report test set, the model was compared with keyword rules and zero-shot MedGemma 4B and 27B. In a partially adjudicated reference, a blinded radiologist labeled 155 reports on which the fine-tuned model or 27B disagreed with the silver labels, plus 45 control reports. Three radiologists rated 150 structured outputs, interleaved with 20 deliberate corruptions, for acceptability. Results: Of 171 reference-urgent reports, the fine-tuned MedGemma 4B flagged 169 (sensitivity 98.8%; specificity 90.8%); before fine-tuning, the same model used zero-shot (full prompt) had missed 107 (descriptive comparison). Zeroshot MedGemma 27B, about seven times larger, detected 111 (sensitivity 64.9%; specificity 99.4%; both P < .001 vs the fine-tuned model). Negation-aware rules missed 29; false alerts per 1,000 reports were 73 for the fine-tuned model versus 5 for MedGemma 27B. Excluding test reports duplicating development reports left sensitivity unchanged and lowered specificity to 85.4%. Readers accepted 88.0% of outputs, and at least one reader detected 19 of 20 corruptions. Conclusion: The compact model fine-tuned on Turkish head CT reports showed higher urgent-finding sensitivity than the zero-shot comparison systems used xiii in this study. The cost was more false alerts. The approach is promising for supporting the communication of urgent findings stated in signed reports; independent and prospective validation is required before clinical use.

Benzer Tezler

  1. Ovulasyon indüksiyonu tedavisinde folliküler gelişimin ultrasonografik takibi

    Başlık çevirisi yok

    MERİH BAYRAM

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    Gazi Üniversitesi

    Kadın Hastalıkları ve Doğum Ana Bilim Dalı

    Yükleniyor...

  2. Vergi uyuşmazlıklarının idari aşamada çözümlenmesi

    Başlık çevirisi yok

    ŞÜKRÜ KIZILOT

    Doktora

    Türkçe

    Türkçe

    1985

    Gazi Üniversitesi

    Maliye Ana Bilim Dalı

    Yükleniyor...

  3. Bir ilaç fabrikasında personel gereksinmesinin belirmesi seçilmesi ve elde tutulmasına yönelik bir uygulama çalışması

    Başlık çevirisi yok

    EMİNE BOZBAĞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1989

    İstanbul Üniversitesi

    Çalışma Ekonomisi ve Endüstri İlişkileri Ana Bilim Dalı

    Yükleniyor...

  4. Çimentonun sertleşmesi üzerinde kimyasal komponentlerin etkisi

    Başlık çevirisi yok

    NACİYE TÜRKEL

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Uludağ Üniversitesi

    Kimya Ana Bilim Dalı

    Yükleniyor...

  5. Halvetiyyenin Şa'baniyye kolu ve Şa'ban-ı Veli

    Başlık çevirisi yok

    L. NİHAL YAZAR

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Gazi Üniversitesi

    Yükleniyor...