Geri Dön

Bileşik eğilmeye maruz betonarme elemanlarda donatı aderansının beton özelliklerine bağlı olarak incelenmesi

According to concrete features the investigation of bond strength of reinforcement in reinforced concrete elements subject to combined bending

  1. Tez No: 116684
  2. Yazar: KAZIM TÜRK
  3. Danışmanlar: Y.DOÇ.DR. M. ŞÜKRÜ YILDIRIM
  4. Tez Türü: Doktora
  5. Konular: İnşaat Mühendisliği, Civil Engineering
  6. Anahtar Kelimeler: Kirişler, donatı-beton aderansı, nervürlü donatı, bileşik eğilme, ekleme uzunluğu, Beams, bond of reinforcing bar-concrete, deformed bar, combined bending, splice length
  7. Yıl: 2002
  8. Dil: Türkçe
  9. Üniversite: Fırat Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: İnşaat Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 96

Özet

in ÖZET DOKTORA TEZİ BİLEŞİK EĞİLMEYE MARUZ BETONARME ELEMANLARDA DONATI ADERANSININ BETON ÖZELLİKLERİNE BAĞLI OLARAK İNCELENMESİ Kazım TÜRK Fırat Üniversitesi Fen Bilimleri Enstitüsü İnşaat Mühendisliği Anabilim Dalı 2002, Sayfa: 96 Çalışmanın asıl amacı, donatı aderans dayanımının tanımlanmasında kullanılabilecek bir amprik denklem geliştirmektir. Bu çalışmada, fc>30 MPa betondan üretilmiş ve büyük boyutlu 27 adet kiriş numunesi test edilmiştir. Her bir kiriş, açıklık ortasında bindirmeli ekli iki çekme donatısı yerleştirilerek tasarlanmıştır. Ekleme uzunluğu, donatı akma noktasına ulaşmadan önce, ekleme bölgesindeki beton örtünün yarılması ile aderans göçmesi olabilecek şekilde seçilmiştir. Deneyler esnasında, donatı çapı ve yükleme durumu, değişken parametre olarak alınmıştır. Birinci seri deneylerde, 9 adet kiriş numunesi, sabit moment bölgesindeki ekleme uzunluğu kenarlarından pozitif eğilme ile yüklenmiştir. İkinci ve üçüncü seri deneylerde ise, toplam 18 adet kiriş numunesi, pozitif eğilmeye ilaveten, numunenin her iki ucundan merkezi eksenel basınç kuvvete maruz bırakılmıştır. Sonuç olarak, hem basit hem de bileşik eğilme yüklemesi altında, donatı çapı arttıkça, aderans dayanımının azaldığı fakat eksenel basınç kuvvetin, aynı donatı çaplı numuneler esas alındığında, hem aderans hem de düktiliteyi arttırdığı tespit edilmiştir.

Özet (Çeviri)

IV ABSTRACT Phd Thesis ACCORDING TO CONCRETE FEATURES, THE INVESTIGATION OF BOND STRENGTH OF REINFORCEMENT IN REINFORCED CONCRETE ELEMENTS SUBJECT TO COMBINED BENDING Kazan TÜRK Fırat University Graduate School of Natural and Applied Sciences Department of Civil Engineering 2002, Page: 96 The primary aim of this study was to develop an empiricial equation, which could used to define bond strength of reinforcement. In this study, twenty seven beams, which were produced from fc >30 MPa concrete and had large size, were tested. Each beam was designed to include two bars in tension, spliced at the center of the span. The splice length was selected so that bars would fail in bond, splitting the concrete cover in the splice region, before reaching the yield point. In all experiments, the variables used were the reinforcing bar diameter and loading condition. In the first series experiments, nine beam specimens were loaded in positive bending with the splice in a constant moment regioa In the second and third series experiments, total eighteen beam specimens were subjected to axial pressure force in addition to positive bending. As results, bond strength reduced as the bar diameter increased but axial pressure force for the same bar diameter increased both bond strength and ductility.

Benzer Tezler

  1. Sera sistemlerinde öngerilmeli beton kolonların tasarımı ve taşıma kapasitelerinin hesaplanması

    Design and calculation of the load carrying capacity of prestressed concrete columns in greenhouse systems

    SEÇKİN SAYGIN

    Yüksek Lisans

    Türkçe

    Türkçe

    2023

    ZiraatAkdeniz Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    DOÇ. DR. FERHAT ERDAL

  2. Çözelti ve vakum esaslı yöntemler ile perovskit güneş hücrelerinin üretimi ve karakterizasyonu

    Production of perovskite solar cells by solution and vacuum based methods and their characterization

    İSMAİL CİHAN KAYA

    Doktora

    Türkçe

    Türkçe

    2021

    EnerjiKonya Teknik Üniversitesi

    Metalurji ve Malzeme Mühendisliği Ana Bilim Dalı

    DOÇ. DR. HASAN AKYILDIZ

    PROF. DR. SAVAŞ SÖNMEZOĞLU

  3. Optimal design of power transmission shafts

    Güç iletim millerinin optimum tasarımı

    A.NECİP ATAY

    Yüksek Lisans

    İngilizce

    İngilizce

    1998

    Makine MühendisliğiOrta Doğu Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    DOÇ. DR. TUNA BALKAN

  4. Fisetin ve mirisetin flavonoidlerinin Caernorhabditis elegans' ta yaşam uzunluğu ve stres direncine etkilerinin araştırılması

    Investigation of the effects of fisetin and myricetin flavonoids on lifespan and stress resistance in Caernorhabditis elegans

    SEREN ÇELİKEL

    Yüksek Lisans

    Türkçe

    Türkçe

    2022

    BiyolojiAkdeniz Üniversitesi

    Biyoloji Ana Bilim Dalı

    DOÇ. DR. MEHMET AKİF KILIÇ