Geri Dön

Polivinilpirolidon (PVP) ve tiyosemikarbazitin (TSC) betonarme demirinin korozyon davranışına ve beton dayanımı üzerine etkilerinin araştırılması

Investigation of the effects of polyvinylpyrolidone (PVP) and thiosemicarbazide (TSC) on the behavior of reinforcing steel corrosion and concrete strength

  1. Tez No: 128974
  2. Yazar: A. ALİ GÜRTEN
  3. Danışmanlar: PROF. DR. KADRİYE KAYAKIRILMAZ, PROF. DR. MEHMET ERBİL
  4. Tez Türü: Doktora
  5. Konular: İnşaat Mühendisliği, Kimya, Civil Engineering, Chemistry
  6. Anahtar Kelimeler: Korozyon, Polivinilpirolidon, Tiyosemikarbazit, Betonarme demiri, AC İmpedans, Beton dayanımı IV, Beton dayanımı, Betonarme çelik, Polivinilpirollidon, Corrosion, Polyvinylpyrrolidone, Thiosemicarbazide, Reinforcing steel, AC Impedance, Compressive strength VI, Concrete strength, Reinforced concrete steel, Polyvinylpyrrollidone
  7. Yıl: 2002
  8. Dil: Türkçe
  9. Üniversite: Niğde Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Kimya Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

ÖZET POLİVİNİLPİROLİDON (PVP) VE TİYOSEMİKARBAZİTİN (TSC) BETONARME DEMİRİNİN KOROZYON DAVRANIŞINA VE BETON DAYANIMI ÜZERİNE ETKİLERİNİN ARAŞTIRILMASI GÜRTEN A. Ali Niğde Üniversitesi Fen Bilimleri Enstitüsü Kimya Anabilim Dalı Danışman : Prof. Dr. Kadriye KAYAKIRILMAZ İkinci Danışman : Prof. Dr. Mehmet ERBİL Ekim 2002, 221 sayfa Bu araştırmada, inşaat demiri (§ 10 x 50 mm) ve PKÇ 32,5 çimentosundan PVP veya TSC katılarak ya da katılmadan hazırlanan beton elektrot, çalışma elektrodu, Pt, karşı elektrot ve SCE, referans elektrot olarak kullanılarak 0,1 M NaCl ve 0,1 M Na2S04 içeren ortamlarda, akım-potansiyel, zamana karşı; polarizasyon direnci, korozyon potansiyeli ve galvanik akım eğrileri çizilerek, AC-impedans spektrumlan oluşturularak, karma ya da temas suyuna katılan PVP ve TSC'nin, betonun mekanik özellikleri ile betonarme çeliğinin korozyonuna inhibitor etkilerini belirlemek amaçlanmıştır. Karma suyu olarak distile suda 10"3 M TSC veya 100 ppm PVP içeren elektrotların, 0,1 M NaCl ve 0,1 M Na2S04'lü temas suyunda, katkısız ortamlara göre, akım yoğunluğu ve galvanik akım yoğunluğu değerlerinde azalma, polarizasyon direnci (Rp) değerlerinde artma, Ecor değerlerinde daha pozitif potansiyellere kayma gözlenmiştir. Nyquist diyagramlarından, klorürlü ortamlarda, temas suyuna eklenen katkıların, toplam direnci, karma suyuna eklenen katkılardan daha fazla arttırdıkları, sülfatlı ortamlarda, karma veya temas suyuna eklenen katkıların, toplam direnci, yaklaşık aynı oranlarda arttırdıkları saptanmıştır. Söz konusu koşullarda TSC ve PVP'nin zayıf bir inhibisyon etkisi gösterdikleri sonucuna varılmıştır. TSC ve PVP'nin zayıf etkileri, bu moleküllerin, beton porlarını kapatarak, betonun geçirgenliğini azalttıkları, dolayısıyla agresif klorür ve sülfat iyonlarının demir yüzeyine yaklaşarak yük transferinin gerçekleştirmesine kısmen engel oldukları şeklinde yorumlanmıştır. Yirmi sekiz günlük kür sonunda, beton basınç dayanım değerlerinin dağılım aralığı, 18,1-27,9 IIIMPa olmuştur. En dayanıklı betonlar, klorürlü ortamda PVP'nin karma suyuna, sülfatlı ortamda TSC'nin temas suyuna katılmasıyla elde edilmiştir. Deneysel veriler doğrultusunda, betonarme çeliğinin korozyonunun, kontrol altına alınmasında, TSC ve PVP'nin, kullanılması önerilmiştir.

Özet (Çeviri)

ABSTRACT INVESTIGATION OF THE EFFECTS OF POLYVINYLPYROLIDONE (PVP) AND THIOSEMICARRAZIDE (TSC) ON THE BEHAVIOR OF REINFORCING STEEL CORROSION AND CONCRETE STRENGTH GÜRTEN A. Ali Niğde University Graduate School of Natural and Applied Sciences Department of Chemistry Supervisor : Prof. Dr. Kadriye KAYAKIRILMAZ Co-Advisor : Prof. Dr. Mehmet ERBİL October 2002, 221 pages In this study, a steel bar (<j) 10 x 50 mm) was embedded in the center of Portland (PKÇ 32.5) concrete cylinder (§ 40 x 70 mm), w/c of the concrete was 0.5. The effect of admixtures, namely PVP and TSC, in concrete or in external solution on the corrosion resistance of steel reinforced concrete was assessed by measuring AC Impedance, current- potential, polarization resistance, corrosion potential and galvanic current during immersion in 0.1 M NaCl or 0.1 M NaîS04 solutions. Setting time was 60 days. Electrochemical testing was performed in a three-electrode cell. Saturated calomel electrode (SCE) and platinum foil were used as reference and auxiliary electrodes, respectively. Compressive strength of these specimens was also measured. The concretes containing distilled water and 10"3 M TSC or 100 ppm PVP as mixing solution, and 0.1 M NaCl or 0.1 M Na2S04 as external solution were most effective for improving the corrosion resistance, due to decrease of the current density, increase of the polarization resistance and shift to more noble potential than that the concretes not containing additives. Nyquist diagrams indicate that addition of TSC or PVP to the external solution in the chloride medium or to the either mixing or external solution in the sulfate medium, increase the resistance. Thus, it was interpreted that the weak influence of TSC or PVP molecules blocked partially into concrete pore, diffusion becomes more difficult and prevent diffusion of aggressive ions to the metal surface. The range of the compressive Vstrength values of specimens cured for 28 days was 18.1-27.9 MPa. The strongest concretes were admixed with PVP as mixing solution in chloride medium, TSC as external solution in sulfate medium. According to experiment results, it is suggested that PVP and TSC could be used to control the corrosion of reinforcing steel bar.

Benzer Tezler

  1. Polietilenoksit (PEO) ve polivinilpirolidon (PVP)'un kimyasal ilgi profilleri ve karışabilirlikleri

    Chemical affinity profiles and miscibilities of polyethylene oxide (PEO) and polyvinylpyrrolidone (PVP)

    MİRAY KOÇ

    Yüksek Lisans

    Türkçe

    Türkçe

    2016

    KimyaHacettepe Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. ALİ GÜNER

  2. PVP/Ganoderma lucidum kompozitlerinin hazırlanması, karakterizasyonu ve bazı biyolojik özelliklerinin belirlenmesi

    Preperation, characterization and determination of some biological properties of PVP/Ganoderma lucidum composites

    İREM AKINCI

    Yüksek Lisans

    Türkçe

    Türkçe

    2018

    BiyokimyaBalıkesir Üniversitesi

    Moleküler Biyoloji ve Genetik Ana Bilim Dalı

    PROF. DR. SERAP DOĞAN

  3. Au/(nanografit-PVP)/n-Si (MPS) yapıların hazırlanması ve elektrik ile dielektrik özelliklerinin geniş bir frekans ve voltaj aralığında incelenmesi

    The fabrication of Au/(nanographite-PVP)/n-Si (MPS) structures and investigation of their electrical and dielectrical properties in a wide range of frequency and voltage

    AHMET MUHAMMED AKBAŞ

    Doktora

    Türkçe

    Türkçe

    2021

    Fizik ve Fizik MühendisliğiGazi Üniversitesi

    İleri Teknolojiler Ana Bilim Dalı

    PROF. DR. ŞEMSETTİN ALTINDAL

  4. Au/(NiS:PVP)/n-Si (MPS) yapısının kapasitans-voltaj (C-V) ve iletkenlik-voltaj (G/w-V) ölçümlerini kullanarak elektriksel özelliklerinin frekansa bağlı incelenmesi

    Investigation of electrical properties of Au/(NiS:PVP)/n-Si (MPS) structure using capacitance-voltage (C-V) and conductance-voltage (G/w-V) measurements depending on frequency

    MURAT ULUSOY

    Yüksek Lisans

    Türkçe

    Türkçe

    2021

    Fizik ve Fizik MühendisliğiGazi Üniversitesi

    Fizik Ana Bilim Dalı

    DOÇ. DR. PERİHAN DURMUŞ

  5. Tuzluluk ve/veya kuraklık stresi altındaki buğday fidelerinde PVP kaplı bakır nanopartiküllerin büyüme, antioksidan sistem ve stres toleransı üzerine etkilerinin belirlenmesi

    Determination of the effects of PVP-coated copper nanoparticles on growth, antioxidant system and stress tolerance in wheat seedlings under salinity and/or drought stress

    RUMEYSA EKİM LEVENTOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2024

    BiyoteknolojiSelçuk Üniversitesi

    Biyoteknoloji Ana Bilim Dalı

    PROF. DR. EVREN YILDIZTUGAY

    DR. ÖĞR. ÜYESİ BÜŞRA ARIKAN ABDULVELİ